User manual CITIZEN CLP COMMAND REFERENCE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITIZEN CLP. We hope that this CITIZEN CLP user guide will be useful to you.


CITIZEN CLP COMMAND REFERENCE: Download the complete user guide (659 Ko)

Manual abstract: user guide CITIZEN CLPCOMMAND REFERENCE

Detailed instructions for use are in the User's Guide.

[. . . ] CITIZEN CLP Series Bar Code Label Printers Command Reference CITIZEN WATCH CO. , LTD. i Notices 1 2 3 4 Be sure to read through the User's Manual before operating the printer. Reproduction, transfer, or transmission of the contents of this manual without prior consent is strictly prohibited. We are not liable for any damage resulting from the use of the information contained herein, regardless of errors, omissions, or misprints. We are not liable for any problems resulting from the use of optional products and consumable supplies other than the designated products contained herein. [. . . ] This command has the same function as A command parameters 1 1-53 and 2 are specified. See page 43. 1-54 Setting offset in direction of column Code Units Setting Cnnnn 0. 01 inch or 0. 1 mm nnnn 4-digit data Inch system Initialization value: 0000 0000 ­ 9999 (0. 00 inch ­ 99. 99 inches) Metric system 0000 ­ 9999 (0. 0 mm ­ 99. 9 mm) Function Sets offset value for printing start position in direction of column (paper left and right) to adjust the position of the total printing contents. [02] n [02] L D11 C0100 190000501150090ABC 1F3306000500050490123456789 E Sets units to inch Starts label format mode Sets pixel size Sets column offset to 1. 0 inch Sets character data "ABC" with smooth font 14pt Sets EAN13 bar code for data "490123456789" Ends label format mode and prints Normal printing starting position Direction of feed Example Input data ABC 4 901234 567894 Printing starting position after setting offset 1-55 Setting number of cuts (2-digit) Code Setting Function Caution cnn nn 00 ­ 99 Initialization value: 01 After printing specified number of labels, cuts paper. This command is invalid unless the auto-cutter is installed and it is turned to ON. Since the initialization value is 01 (one sheet), if the auto-cutter is ON, each label sheet will be cut automatically. When the label is cut by using the paper cut command (o), this must be set to 0 (zero) sheet. Input data below represents that the same contents of the labels are printed ten sheets and cut out every two sheets. [02] n [02] L D22 Q0010 190000700500050ABC c02 E Sets units to inch Starts label format mode Sets pixel size Sets 10 sheets for same label printing Sets character data "ABC" with smooth font 24pt Sets 2 sheets for cutting Ends label format mode and prints Cut Example Input data 5th sheet Cut Direction of feed 10th sheet 9th sheet Cut 4th sheet 3rd sheet Cut 8th sheet 7th sheet Cut 2nd sheet 1st sheet 6th sheet 1-56 Setting pixel size in horizontal and vertical direction Code Units Setting Dhv One dot h v Function 0. 127 mm or 0. 005 inch Initialization value: 2 Initialization value: 2 Dot size in horizontal direction 1, 2 Dot size in vertical direction 1, 2, 3 Specifies pixel size (dot formation units) in the range of 1 dot x 1 dot to 2 dots x 3 dots. If dot size in vertical direction is doubled or tripled, the maximum printing length (printing range) will be doubled or tripled. The following is that dot size in horizontal direction is set to 1 and dot size in vertical direction is set to 1. [02] n [02] L D11 1F3306000500050490123456789 E Sets units to inch Starts label format mode Sets pixel size Sets EAN13 bar code for data "490123456789" Ends label format mode and prints Pixel size 2 x 2 Example Input data h=2 Pixel size 1 x 1 h=1 v=2 v=1 1-57 Completion of setting printing contents (field preparation) and printing labels Code Function E Completes printing contents setting and prints labels. On completion of printing, command interpreter is switched to system level interpreter and system level commands are valid. Printer waits for label format command input until it receives the commands such as E and X, so printer cannot advance to the next operation. Caution Entering previous-defined field character string into global table Code Function G Enters a previous-defined label format character string into global table, allocating one character in alphabetical order from A to P. Reading of character string stored in the global table is executed with command "S. " Input data below represents that data of character string "ABC" is stored in the global table with font 9 and fonts 9 and 5 are printed. [02] n [02] L D22 190000500800120ABC G 150000502800120[02]SA E Ends label format mode and prints Sets units to inch Starts label format mode Sets pixel size Sets character data "ABC" with smooth font 14pt Stores character string "ABC" in global table Example Input data Setting print density (head heat factor) Code Setting Function Hnn nn 00 ­ 30 Initialization value: 10 Sets print density (heat energy is applied to print head). 1-58 Changing units from inch to metric system Code Function Example m Changes units for all-distance-specified-command-parameters from 0. 01 inch to 0. 1 mm. Input data below represents that data "ABC" is specified with units in metric system. Changing units from metric to inch system Code Function n Changes units for all-distance-specified-command-parameters from 0. 1 mm to 0. 01 inch. With reset, units are set to inch system. 1-59 Setting printable area speed Code Setting Pa a C or D E or F G or H I or J K or L M or N O 1-8 One alphanumeric character. 2. 0 inches (50. 8 mm)/sec 3. 0 inches (76. 2 mm)/sec 4. 0 inches (101. 6 mm)/sec 5. 0 inches (127. 0 mm)/sec 6. 0 inches (152. 4 mm)/sec 6. 8 inches (172. 7 mm)/sec 8. 0 inches (203. 2 mm)/sec 1. 0 ­ 8. 0 inches (in increments of 1. 0 inch) Speed setting higher than the specifications of each model is not available. Function Sets printable area speed. 4 901234 567894 Direction of feed Unprintable area Sa Printable area Pa 4 901234 567894 Unprintable area Sa Printable area Pa 4 901234 567894 1-60 Setting backfeed speed Code Setting pa a One alphanumeric character. 2. 0 inches (50. 8 mm)/sec 3. 0 inches (76. 2 mm)/sec 4. 0 inches (101. 6 mm)/sec 5. 0 inches (127. 0 mm)/sec 6. 0 inches (152. 4 mm)/sec 6. 8 inches (172. 7 mm)/sec 8. 0 inches (203. 2 mm)/sec 1. 0 ­ 8. 0 inches (in increments of 1. 0 inch) C or D E or F G or H I or J K or L M or N O 1-8 Speed setting higher than the specifications of each model is not available. Function Sets backfeed speed. 1-61 Specifying space between characters Code Setting [1b] Pnn Data in [ ] is hex. nn Amount of space between characters 00 ­ 99 Initialization value: 00 Function Example Adds specified space between characters to all characters. Input data below represents that data without specification of space between characters and data with specification of 10 to space between characters are set and printed. [. . . ] In case of the continuous paper, specify the label length with the C command. Difference between the maximum and minimum values of the sensor reading voltage is 0. 8 V or more. Sensor adjustment and paper characteristic verification (voltage verification) can be performed with the Maintenance mode. Stop key pressed HeadOpen PaperEnd PaperErr (continued) 1-143 (continued) Indication RibonOut Description Ribbon end Corrective actions Check the contents and clear with the Stop key. Correct the faulty setting of the print mode (directthermal or thermal-transfer). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN CLP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN CLP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.