User manual CITIZEN CH-452

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITIZEN CH-452. We hope that this CITIZEN CH-452 user guide will be useful to you.


CITIZEN CH-452 : Download the complete user guide (1704 Ko)

Manual abstract: user guide CITIZEN CH-452

Detailed instructions for use are in the User's Guide.

[. . . ] · Putting on the cuff is one of the most important tasks for ensuring proper measurement of blood pressure. Wind the cuff around the arm and tighten it so that one finger may be inserted between the cuff and arm. · When you feel like relieving yourself, you should do so before measuring blood pressure. · Measure blood pressure where the room temperature is about 20°C. [. . . ] · Measure blood pressure where the room temperature is about 20°C. Do NOT measure blood pressure when it is too cold (below 10°C) or too hot (above 40°C) in the room. · Do NOT measure blood pressure immediately after drinking coffee or tea or smoking. - Eng 3 - · Measure blood pressure with a relaxed and quiet posture. Keep the center of the cuff at the level of your heart, and do NOT move your arm or talk during measurement. · Do NOT keep on measuring so many times, as your arm will have built up congestion of blood, and you will not get a valid reading. PRECAUTION FOR USE AND MAINTENANCE Precautions for use · If you suffer from heart disease, high blood pressure or other circulatory disease, please consult your doctor first. · If you feel abnormal pressure of the cuff during use or any other irregularity, reduce the pressure by immediately switching off the power or removing the batteries and consult the sales outlet where purchased. · If you think the measured value is abnormal or if measuring makes you feel unwell, discontinue use and consult your doctor. · Measurement of blood pressure may not be possible for someone with a weak pulse or arrhythmia. · If blood pressure is measured repeatedly, an accurate result will not be achieved. · The memory is erased if the batteries are removed for replacement, etc. and a record should be kept of any necessary data. Precautions for maintenance · Do NOT store the blood pressure monitor where it will be exposed to direct sunlight, high temperature (over 60°C), low temperature (below ­20°C), high relative humidity (over 95%) or in a dusty place. Turn power off Press the "Power Switch" to turn OFF. English 6. Subsequent measurements AVE. 1 2 3 4 5 6 7 PULSE/min CH-40 3C When a pulse is detected, the pressure value moves to the right side of the display. At this time the mark "Q" flashes and buzzer sounds. SYSTOLIC mmHg DIASTOLIC mmHg SELECT MEMO RY START POWE R AVE. 1 2 3 4 5 6 7 PULSE/min When the diastolic pressure value is detected, the measurement is completed and buzzer sounds. Systolic pressure is displayed on the left and diastolic pressure on the right side of the display. 2 to 3 seconds after completion of measurements, the mark "w" appears and air will deflate immediately. When a measurement need to be made again, just press the "Start Switch" again. 7. Change of the pressure-setting value CH-40 3C SELECT MEMO RY START POWE R SYSTOLIC mmHg DIASTOLIC mmHg AVE. 1 2 3 4 5 6 7 PULSE/min 2 or 3 seconds later, pressure value and pulse appear alternately on the display. When the pressure setting is needed to be changed, press the "Pressure Setting Switch" and select optimum value. - Eng 9 - 8. Memory recall CH-40 3C SYSTOLIC mmHg DIASTOLIC mmHg AVE. SELEC T MEMO RY START POWE R 1 2 3 4 5 6 7 PULSE/min · By a second depressing of "Memory Recall Switch", the value for latest (last measured value) blood pressure is displayed. The " ] " mark shifts to right (from "Ave. " to "1") and notify that the value is the last measured (newest one) value. SYSTOLIC mmHg DIASTOLIC mmHg This blood pressure monitor has a function which is able to display last measured value. · Press the "Memory Recall Switch" to recall the last measured blood pressure. The last measured systolic and diastolic blood pressure are displayed (Value of the pulse is not memorized nor displayed). SYSTOLIC mmHg DIASTOLIC mmHg AVE. 1 2 3 4 5 6 7 PULSE/min · By a third depressing of "Memory Recall Switch", the value for next later blood pressure is displayed. [. . . ] The " ] " mark shifts to right (from "Ave. " to "1") and notify that the value is the last measured (newest one) value. SYSTOLIC mmHg DIASTOLIC mmHg This blood pressure monitor has a function which is able to display last measured value. · Press the "Memory Recall Switch" to recall the last measured blood pressure. The last measured systolic and diastolic blood pressure are displayed (Value of the pulse is not memorized nor displayed). SYSTOLIC mmHg DIASTOLIC mmHg AVE. 1 2 3 4 5 6 7 PULSE/min · By a third depressing of "Memory Recall Switch", the value for next later blood pressure is displayed. The " ] " mark shifts to right (from "1" to "2") and notify that the value is the next later one. SYSTOLIC mmHg DIASTOLIC mmHg AVE. 1 2 3 4 5 6 7 PULSE/min · By a first depressing of "Memory Recall Switch", averaged blood pressure is displayed and " ] " mark flashes to notify that the displayed value is averaged value. AVE. 1 2 3 4 5 6 7 PULSE/min · As per the same above-mentioned method, you may recall 7 last measured values by depressing of "Memory Recall Switch". - Eng 10 - -- Memory function works on for approximately 3 seconds or until another switches are pressed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN CH-452




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN CH-452 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.