User manual CITIZEN CH-403C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITIZEN CH-403C. We hope that this CITIZEN CH-403C user guide will be useful to you.


CITIZEN CH-403C : Download the complete user guide (152 Ko)

Manual abstract: user guide CITIZEN CH-403C

Detailed instructions for use are in the User's Guide.

[. . . ] 22°C) 6V DC +10°C +40°C, 30% 85%RH ­20°C +60°C, 10% 95%RH 135mm(W) × 130mm(D) × 50. 5mm(H) Approx. 360g (Apparatus and batteries) Type B equipment Cuff, 4 "AA" (R6P) batteries, Instruction manual *Specifications may be changed without notice in the event of improvements being made. - Eng 2 - English CLEANING METHOD OF CUFF After cleaning the cuff with a neutral detergent, lightly rinse it with water and let it dry in the air. Also, be careful not to get water into the air hose. GENERAL REMARKS General Remarks on blood pressure measurement · If the cuff is to be deflated quickly, depress "POWER" switch. [. . . ] · If blood pressure is measured repeatedly, an accurate result will not be achieved. · The memory is erased if the batteries are removed for replacement, etc. and a record should be kept of any necessary data. Precautions for maintenance · Do NOT store the blood pressure monitor where it will be exposed to direct sunlight, high temperature (over 60°C), low temperature (below ­20°C), high relative humidity (over 95%) or in a dusty place. · Do NOT expose the blood pressure monitor to under force or vibration, or drop it. · Remove the battery/batteries when not in use for a long period. · NEVER wipe the blood pressure monitor with thinner or benzene, as they may damage it. · When the monitor is very dirty, wipe it clean with a cloth moistened with Sterilizing alcohol or a neutral detergent, and then wipe it with a dry cloth. Do NOT use thinner or benzene. Nature and frequency of maintenance: This products is designed for use over an extended period of time; however, it is generally recommended that it be inspected every two years to ensure proper function and performance. - Eng 4 - Protect the nature environment: Please help protect natural environment by respecting national and/or local recycling regulations when disposing of the batteries and the products at the end of their useful lives. Manufacturer: Name: Address: Premier Precision Ltd. Block E, G-H, 6 th floor, Phase 2, Yip Fat Factory Building, 73-75 Hoi Yuen Road, Kwun Tong, Kowloon, Hong Kong English Reference European standard: This products complies with EC instructions 93/42/EEC (Medical Device Directive) and with the following standards: EN 1060-1: 1995 "Noninvasive Sphygmomanometers, Part 1 General Requirements" and EN 1060-3: 1997 "Noninvasive Sphygmo-manometers, Part 3 Supplementary Requirements for Electromechanical Blood-Pressure Measuring Systems". European Representative: Name: Address: WvW elektronische Geräte Vertrieb GmbH. Robert-Koch-Straße 20, D-80538 München, GERMANY MEASUREMENTS 1. Turn power ON CH-40 3C SELECT MEMO RY START POWE R Insert the Hose plug from the cuff into the hose socket at the mainframe until it is tightly connected. Press the "Power switch" for power ON. - Eng 5 - SYSTOLIC mmHg DIASTOLIC mmHg SYSTOLIC mmHg DIASTOLIC mmHg AVE. 1 2 3 4 5 6 7 PULSE/min AVE. 1 2 3 4 5 6 7 PULSE/min All display marks appear for approx. 1 second and buzzer beeps. SYSTOLIC mmHg DIASTOLIC mmHg SYSTOLIC mmHg DIASTOLIC mmHg AVE. 1 2 3 4 5 6 7 PULSE/min Ready for measurement AVE. 1 2 3 4 5 6 7 PULSE/min After all display marks are disappeared, deflation mark "w" appears for approx. 1 second (three short beeps notify you of ready for measurement) then the last pressure setting value appears for approx. Attaching of arm cuff and posture during measurement Unfasten and open the cuff as figure. - Eng 6 - English Wind the arm cuff around the left upper arm tightly so that the bottom edge of the cuff is positioned about 1-2 cm (about 1 inch) above the elbow joint. 1 ­ 2cm The cuff should be wound so that one finger can be inserted under the cuff. [. . . ] The last measured systolic and diastolic blood pressure are displayed (Value of the pulse is not memorized nor displayed). SYSTOLIC mmHg DIASTOLIC mmHg AVE. 1 2 3 4 5 6 7 PULSE/min · By a third depressing of "Memory Recall Switch", the value for next later blood pressure is displayed. The " ] " mark shifts to right (from "1" to "2") and notify that the value is the next later one. SYSTOLIC mmHg DIASTOLIC mmHg AVE. 1 2 3 4 5 6 7 PULSE/min · By a first depressing of "Memory Recall Switch", averaged blood pressure is displayed and " ] " mark flashes to notify that the displayed value is averaged value. AVE. 1 2 3 4 5 6 7 PULSE/min · As per the same above-mentioned method, you may recall 7 last measured values by depressing of "Memory Recall Switch". - Eng 10 - -- Memory function works on for approximately 3 seconds or until another switches are pressed. (Even if the last measured value is displayed, you are able to start the measurements by pressing of "Start Switch" or you are able to change the pressure-setting value by pressing of "Pressure Setting Switch" or you are able to turn OFF by depressing of "Power Switch") -- Memory recall function does not work during automatic inflation and blood pressure measurement are being made. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN CH-403C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN CH-403C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.