User manual CITIZEN CH-311B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITIZEN CH-311B. We hope that this CITIZEN CH-311B user guide will be useful to you.


CITIZEN CH-311B : Download the complete user guide (401 Ko)

Manual abstract: user guide CITIZEN CH-311B

Detailed instructions for use are in the User's Guide.

[. . . ] Measure your blood pressure where the room temperature is about 20°C. DO NOT measure blood pressure when it is too cold (below 10°C) or too hot (above 40°C) in the room. DO NOT try to measure blood pressure immediately after drinking coffee or tea or smoking. Keep the center of the cuff at the level of your heart, and DO NOT move your arm or talk. [. . . ] 14. If you use a cardiac pacemaker, consult your physician before use. PRECAUTION FOR USE AND MAINTENANCE 15. Be sure to use this unit only for measuring blood pressure. The natural rubber may cause any allergic reaction such as itching, flare, urticaria, swelling, fever, difficult breathing, asthma status, blood pressure drop or any shock. * If any of the symptoms as shown above is observed, immediately stop using this product and consult your physician. 18. Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard, Electronic or automated sphygmomanometers. 19. Measurement of blood pressure may not be possible for someone with a common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation. English Precaution for maintenance 1. DO NOT store the blood pressure monitor where it will be exposed to direct sunlight, high temperature (over 60°C), low temperature (below -20°C), high relative humidity (over 95%) or in a dusty place. DO NOT drop or expose the blood pressure monitor to under force or vibration. When the monitor is very dirty, wipe it clean with a cloth moistened with Sterilizing alcohol or a neutral detergent, and then wipe it with a dry cloth. NEVER wipe the blood pressure monitor with thinner or benzene, as they may damage it. Also, be careful not to get water into the air hose. - Eng 4 - - Eng 5 - PRECAUTION FOR USE AND MAINTENANCE IDENTIFICATION OF PARTS English Nature and frequency of maintenance: This product is designed for use over an extended period of time; however, it is generally recommended that it be inspected every two years to ensure proper function and performance. Systolic blood pressure display section Diastolic blood pressure display section Pulse display section Protect the nature environment: Please help to protect natural environment by respecting natural and/or local recycling regulations when disposing of the batteries and the products at the end of their useful lives. WEEE MARK If you want to dispose this product, do not mix with general household waste. There is a separate collection systems for used electronics products in accordance with legislation under the WEEE Directive (Directive 2002/96/EC) and is effective only within European Union. Power switch ( ) : OFF : ON Pumping bulb Hole of holding strap Reference European standard: The blood pressure measuring device corresponds to regulation EN60601-1-2. The device has been tested and homologated in accordance with EN60601-1-2 for EMC. This does not guarantee in any way that the device will not be affected by electromagnetic interference. Avoid using the device in high electromagnetic environment. Air Hose socket Name : Address : FLAT A-B, 4TH FLOOR, HUNG MOU INDUSTRIAL BUILDING, 62 HUNG TO ROAD, KWUN TONG, KOWLOON, HONG KONG ( : Manufacturer) Battery compartment cover European Representative: Name : WvW electronische Geräte Vertrieb GmbH Address : Fintelmannstraße 20/Eingang, Martin-Heydert-Straße, D-14109 Berlin, Germany - Eng 6 - - Eng 7 - IDENTIFICATION OF PARTS HOW TO LOAD BATTERIES 1 Open the battery compartment cover. 1 While pressing the lock section of the battery compartment cover, 2 pull the cover toward you to open. 1 English 2 Exhaust button 2 Place the batteries compartment. in the Fit the batteries paying attention to the positive + and negative ­ terminals. Arm cuff 3 Close the battery compartment cover. Push the cover in the direction of the arrow. Air hose plug Air hose - Eng 8 - - Eng 9 - HOW TO UNLOAD THE BATTERIES POINTS FOR ACCURATE MEASUREMENT Blood pressure varies with posture, the time of day or numerous other factors. It is recommended to measure blood pressure at the same time each day in the same posture. English 1 Open the battery compartment cover. ( See page 9 "HOW TO LOAD BATTERIES". ) Measurement in sitting posture 1 Place your arm on a table or similar surface stretching out the portion from the elbow to the hand. 3 Lightly open your hand on the table with palm up and relax your fingers. 4 Do not move your body or talk during measurement. 2 Remove the batteries. 3 Close the battery compartment cover. Measurement in laying posture Replacing the batteries · Replace the batteries with two new "AAA" batteries when appears on the display, or when nothing appears on the display when the POWER switch is pressed. · The memory is erased if the batteries are removed for replacement, etc. · Do not use the alkaline dry battery and manganese dry battery together. · Dispose of used batteries properly in accordance with local regulations. * Relax yourself not to apply pressure to the arm cuff. 1 Lie down your head facing the ceiling. 4 Do not move your body or talk during measurement. - Eng 10 - - Eng 11 - HOW TO WRAP THE ARM CUFF HOW TO WRAP THE ARM CUFF 1 Unroll the arm cuff. · When the arm cuff comes off, pass it through metal bar, directing the Velcro-attached side to the outer surface. metal bar Velcro 4 Draw the end of the arm cuff to fit it on the arm and secure with Velcro. · Carefully place the arm taking care to obtain adequate tightness, not too tight or loose. Adequate tightness is obtained when you can place a finger between the cuff and your arm. English 2 Put the arm cuff around your arm so that the air hose comes to the left palm side. · The arm cuff should be put on the bare arm or over a light-weight clothing. [. . . ] Physicians lay importance on blood pressure measurements taken at home. It is recommended to measure your blood pressure at the same time on a daily basis and to record blood pressure variation. Point to be checked Check whether batteries are dead. Check whether batteries are installed with incorrect polarity ( + ­ ). Load the batteries with correct polarity. Q A No measurement is possible. Check if the arm cuff is wrapped properly. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN CH-311B




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN CH-311B will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.