User manual CITIZEN CH-302B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITIZEN CH-302B. We hope that this CITIZEN CH-302B user guide will be useful to you.


CITIZEN CH-302B : Download the complete user guide (113 Ko)

Manual abstract: user guide CITIZEN CH-302B

Detailed instructions for use are in the User's Guide.

[. . . ] 400 times/6F22 (once a day, room temperature 22°C) 9V DC +10°C~+40°C, 30%~85%RH ­20°C~+60°C, 10%~95%RH 85mm(W) × 120mm(D) × 35mm(H) Approx. 150g (Apparatus and battery) Type B equipment Cuff, Battery (6F22), Instruction manual *Specifications may be changed without notice in the event of improvements being made. - Eng 2 - English CLEANING METHOD OF CUFF After cleaning the cuff with a neutral detergent, lightly rinse it with water and let it dry in the air. Also, be careful not to get water into the air hose. GENERAL REMARKS General Remarks on blood pressure measurement · If the cuff is to be deflated quickly, depress "POWER" switch. [. . . ] Do NOT measure blood pressure when it is too cold (below 10°C) or too hot (above 40°C) in the room. · Do NOT measure blood pressure immediately after drinking coffee or tea or smoking. - Eng 3 - · Measure blood pressure with a relaxed and quiet posture. Keep the center of the cuff at the level of your heart, and do NOT move your arm or talk during measurement. · Do NOT keep on measuring so many times, as your arm will have built up congestion of blood, and you will not get a valid reading. PRECAUTION FOR USE AND MAINTENANCE Precautions for use · If you suffer from heart disease, high blood pressure or other circulatory disease, please consult your doctor first. · If you feel abnormal pressure of the cuff during use or any other irregularity, reduce the pressure by immediately switching off the power or removing the batteries and consult the sales outlet where purchased. · If you think the measured value is abnormal or if measuring makes you feel unwell, discontinue use and consult your doctor. · Measurement of blood pressure may not be possible for someone with a weak pulse or arrhythmia. · If blood pressure is measured repeatedly, an accurate result will not be achieved. · The memory is erased if the batteries are removed for replacement, etc. and a record should be kept of any necessary data. Precautions for maintenance · Do NOT store the blood pressure monitor where it will be exposed to direct sunlight, high temperature (over 60°C), low temperature (below ­20°C), high relative humidity (over 95%) or in a dusty place. · Do NOT expose the blood pressure monitor to under force or vibration, or drop it. · Remove the battery/batteries when not in use for a long period. · NEVER wipe the blood pressure monitor with thinner or benzene, as they may damage it. · When the monitor is very dirty, wipe it clean with a cloth moistened with Sterilizing alcohol or a neutral detergent, and then wipe it with a dry cloth. Do NOT use thinner or benzene. Nature and frequency of maintenance: This products is designed for use over an extended period of time; however, it is generally recommended that it be inspected every two years to ensure proper function and performance. - Eng 4 - Protect the nature environment: Please help protect natural environment by respecting national and/or local recycling regulations when disposing of the batteries and the products at the end of their useful lives. Manufacturer: Name: Address: Premier Precision Ltd. Block E, G-H, 6th floor, Phase 2, Yip Fat Factory Building, 73-75 Hoi Yuen Road, Kwun Tong, Kowloon, Hong Kong English Reference European standard: This products complies with EC instructions 93/42/EEC (Medical Device Directive) and with the following standards: EN 10601 : 1995 "Noninvasive Sphygmomanometers, Part 1 General Requirements" and EN 1060-3 : 1997 "Noninvasive Sphygmomanometers, Part 3 Supplementary Requirements" for Electromechanical Blood-Pressure Measuring Systems. European Representative: Name: Address: WvW elektronische Geräte Vertrieb GmbH. Robert-Koch-Straße 20, D-80538 München, GERMANY PREPARATION FOR MEASUREMENTS 1. Inserting hoses Bulb hose Cuff hose Take off the battery cover at the back of the unit by sliding it as shown. Insert the cuff hose and bulb hose into the hose connector. - Eng 5 - 3. [. . . ] Power off SYSTOLIC mmHg DIASTOLIC mmHg PULSE/min POWER Flashing SYSTOLIC mmHg DIASTOLIC mmHg Touch the power switch for power off. If this unit is left on after measurement an automatic power-off function turns the power off after approximately 3 minutes. PULSE/min When the measurement is completed, the buzzer beeps, Systolic pressure is displayed on the left and Diastolic pressure on the right. Altemate display Approximately 2 seconds later, blood pressure values and pulse appear alternately on the display Touch the power switch Flashing SYSTOLIC mmHg DIASTOLIC mmHg PULSE/min - Eng 8 - English DESCRIPTION OF DISPLAY MARKS DISPLAY MARK SYSTOLIC mmHg DIASTOLIC mmHg CONDITION/CAUSE The cuff was not inflated to more than 30-40 mmHg above your systolic pressure. CORRECTIVE ACTION Raise the set pressure value by higher level PULSE/min SYSTOLIC mmHg DIASTOLIC mmHg The cuff was inflated to more than 320 mmHg. PULSE/min SYSTOLIC mmHg DIASTOLIC mmHg Exhaust the air within the cuff. Appears when the blood pressure could not be measured accurately. PULSE/min SYSTOLIC mmHg DIASTOLIC mmHg Repeat measurement again. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN CH-302B




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN CH-302B will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.