User manual CITIZEN CBM-810

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITIZEN CBM-810. We hope that this CITIZEN CBM-810 user guide will be useful to you.


CITIZEN CBM-810 : Download the complete user guide (1393 Ko)

Manual abstract: user guide CITIZEN CBM-810

Detailed instructions for use are in the User's Guide.

[. . . ] To ensure reliable operation of the product and to protect it from overheating, do not block or cover these openings. The openings should never be blocked by placing the product on a bed, sofa, rug of other similar surface. This product should never be placed near or over a radiator or heater. This product should not be placed in an built-in installation unless proper ventilation is provided. [. . . ] (Positive logic) : When your printer is in an alarm state, this signal is "LOW". (Negative logic) : When the paper is near its end, this signal is issued. (Positive logic) Note: An alarm condition occurs when the timing of the print head movement sensor is abnormal. c) Power Source *+5V DC : The same +5V output as that of the power source which actuates the control circuits. : Equivalent to "case ground". *GND *FRAME GND 22 CITIZEN CBM-810/720/730/750 User's Manual (2) Electrical Characteristics a) Input Signal Level All input signals are TTL level. c) Input/Output Conditions All of the input signals are pulled up by 1K ohms. All of the output signals are pulled up by 3. 3K ohms. 23 CITIZEN CBM-810/720/730/750 User's Manual (3) Timing Chart a) Data Input and Print Timing (4) Data Receiving Control Your printer is able to receive data sent from the host side when the BUSY signal is LOW, but unable to receive when the BUSY signal is HIGH. (5) Buffering 1) N Type Your printer is provided with a two line input buffer. This makes possible a large amount of data buffering, and therefore, the host side is free immediately after data transmission. 2) 24 CITIZEN CBM-810/720/730/750 User's Manual 9. 9. 1 SERIAL INTERFACE Specifications : Asynchronous a) Synchronism b) Baud rate: RS-232C type Current Loop type : 110, 150, 300, 600, 1200, 2400, 4800, 9600BPS (Selected by user) : 110, 150, 300, 600, 1200BPS (Selected by user) c) Composition of one word: Start bit : 1bit Data bit : 7 or 8 bits (selected by user) Parity bit : Odd, even or no parity (Selected by user) Stop bit : 1bit or more d) Signal Polarity : RS-232C type : *Mark = Logic "1" (-3V to -12V) *Space = Logic "0" (+3V to +12V) : *Mark = Logic "1" (Current ON) *Space = Logic "0" (Current OFF) Current Loop type e) Received Data: RS-232C & Current Loop (RD signal) *Mark = 1 *Space = 0 f) Receiving Control (DTR signal) RS-232C : *Mark: Data Transfer not possible *Space: Data Transfer possible Current Loop: *Mark (Current ON): Data Transfer possible *Space (Current OFF): Data Transfer not possible g) Transmission Control (TD signal) DC1 code (11H) "X" ON : Data Receiving possible DC3 code (13H) "X" OFF: Data Receiving not possible However, this is valid only for type B input buffer (7K). 25 CITIZEN CBM-810/720/730/750 User's Manual 9. 2 Connector Pin Assignment Signal Pin 1 7 3 20 2 11 12 13 18 23 14 16 22 Return Signal Pin Signal Name FG GND RD DTR TD PE FAULT DTR RD RESET Direction Host/ Printer Function Safety Ground Signal Ground Received Data Printer BUSY Signal Transmitted Date Paper End Signal Printer ALARM Signal Printer BUSY Signal Received Data Printer RESET Signal O O O O RS-232C O O O O O O O Current Loop TTL Notes: [1] [2] [3] [4] The signals for RS-232C use are based on EIA RS-232C level. The loop current for Current Loop signal use should be restricted within the range of 10 to 20mA. Please always maintain the "mark state", when received data are not being transferred. The assignment of RS-232C/Current loop/TTL can be performed with the preset jumper (Refer to 10. Compatible Connector (D-Sub connector) : *Printer: 17LE-13 250 (AMPHENOL or equivalent) *Cable Side: 17JE-23 250 (AMPNENOL or equivalent) 26 CITIZEN CBM-810/720/730/750 User's Manual 9. 3 Description of Input/Output Signals (1) Input/Output Signals a) RD : This is the serial signal for received data. [2] Parity error When parity check is designated, and if when checked an error is detected, the ALARM lamp goes on, the buzzer sounds and the related data is ignored. [3] Overrun error When an overrun error is detected, the ALARM lamp goes on, the buzzer sounds and the related data is ignored. 28 CITIZEN CBM-810/720/730/750 User's Manual [4] Other errors When trouble is detected in the printer mechanism, the ALARM lamp goes on, the buzzer is sounded, the FAULT signal is output, and the DTR signal becomes BUSY. After the cause of the trouble has been corrected, the ALARM lamp can be turned off by pressing the LINE switch or by making RESET = "0". (4) Data Receiving Control When the BUSY signal is LOW, your printer receives data from the host side, but when this signal is HIGH, it cannot receive data. (5) Buffering Data transfer to the input buffer is controlled by the DTR and TD signals. Please refer to 9. 3 b) for the DTR signal and 9. 3 f) for the TD signal. 29 CITIZEN CBM-810/720/730/750 User's Manual (6) Electrical Characteristics a) RS-232C Circuit Input (RD) MAX232 or equivalent Mark = (-8V): Stop bit Space = (-8V): Start bit Output (DTR, TD, FAULT) MAX232 or equivalent *DTR (­8V): (+8V): *FAULT (­8V): (+8V): BUSY READY Normal Abnormal *TD Mark = (­8V): 1 Space = (+8V): 1 30 CITIZEN CBM-810/720/730/750 User's Manual b) Current Loop Circuit Input (RD) Mark Space Output (DTR, TD) = Current ON = Current OFF *DTR *TD c) TTL Circuit Output (PE) Current ON : READY Current OFF : BUSY Mark = Current ON Space = Current OFF 7406 or equivalent *PE H: L: Paper empty Paper reaming RESET 7406 or equivalent LOW for RESET 31 CITIZEN CBM-810/720/730/750 User's Manual 10. FUNCTION SELECTION In order to meet the widest possible range of needs, various conditions can be selected by setting the DIP switches and slide switches. 1 2 International country switching 3 4 5 6 7 8 Input buffer Character direction CR cord Mode SEL/DESEL at "power on" 7K Byte Normal CR Character SELECT 2 Line Inverted CR + LF Graphic DESELECT (Refer to the table below) Off *1 *1 Off *1 Off Function Auto Cutter Off No On Yes Factory Setting *1 Off Note : *1) Setting is variable, depending on the type of printer. 2 3 USA OFF OFF FRANCE ON OFF W. GERMANY OFF ON ENGLAND ON ON 32 CITIZEN CBM-810/720/730/750 User's Manual (2) DIP Switch DS2 (Serial interface specifications only) No . l 2 3 4 5 6 Baud rate setting 7 8 bps No 5 6 7 8 110 OFF OFF OFF OFF 150 ON OFF OFF OFF 300 OFF ON OFF OFF 600 ON ON OFF OFF 1200 OF F OF F ON OFF 2400 ON OFF ON OFF 4800 OFF ON ON OFF (Refer to the table below) ON OFF 9600 ON ON ON OFF Function Word length setting Parity check Parity condition Not in use OFF OFF OFF 8 bits YES ODD ON 7 bits NO EVEN Factory Setting OFF ON OFF 33 CITIZEN CBM-810/720/730/750 User's Manual (3) Slide Switch Setting (Serial interface specifications only) RS232-C or 20mA current loop can be selected by changing slide switch SW1 on the control board. [. . . ] [2] Datenbits und Paritätsbit Daten- und Paritätsbits sind die Daten der abgefragten Bits und werden durch den Zustand zum Abtastzeitpunkt repräsentiert. Die Abtastung erfolgt in Zeitintervallen, die der Länge eines Bits entsprechen, und beginnt in der Mitte des Startbits. Die Reihenfolge der Bits, beginnend mit dem am Nächsten zum Startbit liegenden Bit, ist Bit-0, Bit-1 Paritätsbit. (Hinweis: Datenbits basieren auf , , Einpunktabtastung". ) [3] Stoppbit Das Stoppbit besteht aus einem oder mehreren Bits auf , , Zeichen"-Pegel. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN CBM-810




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN CBM-810 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.