User manual CHAMBERLAIN TAC1 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN TAC1. We hope that this CHAMBERLAIN TAC1 user guide will be useful to you.


CHAMBERLAIN TAC1 INSTALLATION: Download the complete user guide (1480 Ko)

Manual abstract: user guide CHAMBERLAIN TAC1INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Function Tip 1 Ring 1 Tip 2 Ring 2 Old Color Standard Green Red Black Yellow New Color Standard White/Blue Blue/White White/Orange Orange/White Home Phone Notes about wire connectors (terminal blocks): · Wire connectors can be removed to simplify wiring. Use ONLY one wire per hole. CA AUTO LL 1 EXIT 2 EXIT M CO HOUSE TELCO Typical Telco Overview NOTES: · The voltmeter measurement between the Tip and Ring should be between 48 and 53 Vdc. · Never run data wires and high voltage wires in the same conduit. The high voltage wires may interfere with the data wires and cause the system to malfunction. [. . . ] · The system's operation will not be affected if any other equipment develops a short circuit across the power line. Connect the transformer into a 110 Vac outlet after all connections have been made, any other type of outlet will cause damage to the system. POWER WIRE TABLE DISTANCE Under 30 feet 30 - 75 feet 75 - 150 feet 150 - 250 feet 250 - 500 feet AC POWER WIRE SIZE 18 AWG 18 AWG 18 AWG 16 AWG 12 AWG 1 2 POWER Refer. Bus 1, 2, 3 Air (1) Conditioner M a in Room Conference Rm 2, 3 Conference Room 2 Com p. 2 Rm Dedicated 10 Amp Minimum Circuit Breaker 12 Vac Power (included) The TAC 1 MUST be grounded. Dedicated Outlet NOTE: Chamberlain is not responsible for conflicts between the information listed in the above table and the requirements of local building codes. Check local building codes before installation. 10 INSTALLATION >> PLUG THE TRANSFORMER INTO THE OUTLET, MOUNT THE UNIT AND SET THE UNIT MASTER CODE PLUG THE TRANSFORMER INTO THE OUTLET Plug the transformer into the 110 Vac outlet. 12 Vac Power (included) 1 2 POWER 110 Vac Outlet 1 2 POWER Check the Power LED is illuminated. NOTE: Once power is applied, the TAC1 will begin to click to indicate that it is powered, and is waiting to be programmed for the unit's Master Code. The Master Code is used to unlock the programming functions of the TAC1. The Master Code should not be distributed as a User Code. MOUNT THE UNIT Mount the unit onto the back panel. Stop and go keystrokes will result in negative tones (low single and triple fail tones). ENABLE TELCO MODE Telco Mode is using the main telephone line for the unit's communications to the house or complex. 3 ? ADJUST RELAY OUTPUT TIME (RELAY 1) The amount of time (in seconds) the relay remains active. Enter the Program Code: MICROPHONE SENSITIVITY Allows the resident to hear the visitor at the unit, 1 = Low, 2 = Medium and 3 = High. Enter the Volume Level: SPEAKER VOLUME Allows the visitor to hear the resident at the unit, 1 = Low, 2 = Medium and 3 = High. Example: 0000 = 0. 5 Seconds (Minimum) 0010 = 10 Seconds 8000 = 8000 Seconds (Maximum) ADJUST RELAY OUTPUT TIME (RELAY 2) The amount of time (in seconds) the relay remains active. Example: 0000 = 0. 5 Seconds (Minimum) 0010 = 10 Seconds 8000 = 8000 Seconds (Maximum) ? ? or 2 or 3 13 PROGRAMMING >> CODE SETUP AND CODE OPERATION CODE SETUP The unit's Master Code is for owner/administrator level commands. The User Codes allow users to activate and latch relays 1 and 2 and to transmit radio commands on channels one and two. Enter the Relay/Channel for the Code to control: 2 or no button is pressed. NOTE: If no button is pressed in step 4, both relays/channels will activate simultaneously. Enter User Code to be deleted: or CODE OPERATION MASTER CODE OPERATIONS TRIGGER RELAY 1 (ONLY) Enter the Master Code: ?ENABLE VACATION (LOCK DOWN) MODE Locks the system from all User Code activity. ? ENTER A TEMPORARY (1 SHOT) USER CODE NUMBER The TAC1 holds 1 temporary User Code. [. . . ] THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, PROBLEMS RELATED TO INTERFERENCE, OR REPLACEMENT OF BATTERIES. UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER'S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN TAC1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN TAC1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.