User manual CHAMBERLAIN T

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN T. We hope that this CHAMBERLAIN T user guide will be useful to you.


CHAMBERLAIN T : Download the complete user guide (3339 Ko)

You may also download the following manuals related to this product:

   CHAMBERLAIN T V2.0 (4414 ko)
   CHAMBERLAIN T QUICK START (776 ko)
   CHAMBERLAIN T INSTALLATION (4461 ko)
   CHAMBERLAIN T REPLACEMENT PARTS (1700 ko)

Manual abstract: user guide CHAMBERLAIN T

Detailed instructions for use are in the User's Guide.

[. . . ] FACTORY SET C2 Wiring See page 8 for other wiring configurations OWNER'S MANUAL MODEL T INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 LISTED DOOR OPERATOR SPECIFICATIONS MOTOR TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous duty HORSEPOWER:. . . . . . . . . . . . . . . . . 1/3, 1/2, 3/4 & 1 Hp Single or Three phase SPEED:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1725 RPM VOLTAGE: . . . . . . . . . . . . . . . . . . . . . . . . . . 115, 220, 230 Single phase 230, 460, 575 Three phase CURRENT: . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate ELECTRICAL TRANSFORMER:. . . . . . . . . . . . . 24VAC CONTROL STATION: . . . . . . NEMA 1 three button station. OPEN/CLOSE/STOP WIRING TYPE: . . . . . . . . . . . . . . . . . C2 (Factory Shipped) Momentary contact to OPEN & STOP, constant pressure to CLOSE, open override plus wiring for sensing device to reverse. LIMIT ADJUST: . . . . . . . . . . . . . . . . Linear driven, fully adjustable screw type cams. Adjustable to 24 feet. MECHANICAL SAFETY DRIVE REDUCTION:. . . . . . . . . . . . . Primary: Heavy duty DISCONNECT: . . . . . . . . . . . . . Quick disconnect door arm for emergency manual door operation. [. . . ] DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM. NING WARNING DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND PERMANENTLY WIRED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. NOTE: THE OPERATOR SHOULD BE ON A SEPARATE FUSED LINE OF ADEQUATE CAPACITY. ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL. POWER WIRING 1. Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Using the 1-1/16" dia conduit access knockout as shown below, bring supply lines to the operator and connect wires to the terminals indicated on the WIRING CONNECTIONS DIAGRAM. DO NOT TURN POWER ON UNTIL YOU HAVE FINISHED MAKING ALL POWER AND CONTROL WIRING CONNECTIONS AND HAVE COMPLETED THE LIMIT SWITCH ADJUSTMENT PROCEDURE. TION WARNING WARNING TO AVOID DAMAGE TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH. WARNING IMPORTANT: THIS UNIT MUST BE PROPERLY GROUNDED. A GROUND SCREW IS SUPPLIED IN THE ELECTRICAL BOX FOR CONNECTION OF THE POWER SUPPLY GROUND WIRE. Refer only to the replacement wiring diagram for all connections. IMPORTANT NOTE: If your wiring diagram is missing, or you are unsure of the wiring type for your operator, contact the customer service department @ 1-800-528-2806. LOCATING THE CONTROL STATION All operators are supplied with some type of control station. A two-position key switch or control station (OPEN/CLOSE) may be added or substituted when requested at the time of order. Mount the control station near the door. WARNING INSTALL THE CONTROL STATION WHERE THE DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING EDGE MUST BE INSTALLED ON THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A REVERSING EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR. MOUNT WARNING NOTICE IMPORTANT: Mount WARNING NOTICE beside or below the push button station. Standard Control Station OPEN Push Buttons WARNING CLOSE TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR STOP WARNING Notice 8 CONTROL WIRING (con't) Radio Controls On all models with type B2 control wiring, a terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. All standard radio control receivers (single channel residential type) may be mounted to this bracket. The operator will then open a fully closed door, close a fully open door, and reverse a closing door from the radio transmitter. However, for complete door control from a transmitter, a commercial three-channel radio set (with connections for OPEN/CLOSE/STOP) is recommended. WARNING DO NOT USE RADIO CONTROLS WITH YOUR OPERATOR UNLESS YOU HAVE INSTALLED SOME TYPE OF ENTRAPMENT PROTECTION DEVICE. THE USE OF RADIO CONTROLS PRESENTS POTENTIAL HAZARDS DUE TO THE USER'S ABILITY TO OPEN OR CLOSE THE DOOR WHEN OUT OF SIGHT OF THE DOOR. IN ADDITION, IF A SINGLE CHANNEL CONTROL IS USED, THE USER WILL NOT BE ABLE TO STOP THE DOOR FROM THE TRANSMITTER. W CAUTION Additional Access Control Equipment Locate any additional access control equipment as desired (but so that the door will be in clear sight of the person operating the equipment), and connect to the terminal block in the electrical enclosure as shown on the FIELD WIRING CONNECTIONS diagram. Any control with a normally (N. O. ) isolated output contact may be connected in parallel with the OPEN button. DO NOT USE THE CONTROL CIRCUIT TRANSFORMER (24VAC) IN THE OPERATOR TO POWER ANY ACCESS CONTROL EQUIPMENT OTHER THAN A STANDARD RESIDENTIAL TYPE RADIO RECEIVER. External Interlock Switch The operator has a terminal connection for an external interlock switch. This switch must be a normally closed (N. C. ) two-wire device with a contact rating of at least 3 amps @ 24VAC. [. . . ] CONNECTION OVERLOAD (UP TO 3/4 HP) GY 1 SAFETY EDGE NOTES: 1) TO REVERSE MOTOR DIRECTION: INTERCHANGE ANY 2 OF THE 3 POWER WIRES AT L1, L2 & L3, OR EXCHANGE PURPLE & GRAY MOTOR LEADS AT CONTACTOR 1 & 3 (3PH UNITS ONLY). **- Transformer Primary Voltage same as Line Voltage. 15 ILLUSTRATED PARTS ­ ELECTRICAL BOX S7 S1 S6 S5 S2 S8 S4 S9 L1 L3 S3 L7 1 6 9 5 L8 L6 L2 8 L2 L5 L4 3 7 10 2 4 16 REPLACEMENT PART KITS - ELECTRICAL BOX Below are replacement kits available for your operator. For replacement of electrical box, motor or brake components be sure to match model number of your unit to kit number below to ensure proper voltage requirements. Optional modifications and/or accessories included with your operator may add or remove certain components from these lists. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN T




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN T will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.