User manual CHAMBERLAIN SL930

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN SL930. We hope that this CHAMBERLAIN SL930 user guide will be useful to you.


CHAMBERLAIN SL930 : Download the complete user guide (3781 Ko)

You may also download the following manuals related to this product:

   CHAMBERLAIN SL930 ADDENDUM (224 ko)

Manual abstract: user guide CHAMBERLAIN SL930

Detailed instructions for use are in the User's Guide.

[. . . ] MODEL SL930 DC BB HEAVY DUTY COMMERCIAL SLIDE GATE OPERATOR MODEL SL930 2 YEAR WARRANTY Serial # ________________________ (located on electrical box cover) Installation Date__________________ MODEL SL930 IS FOR VEHICULAR PASSAGE GATES ONLY AND IS NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE TABLE OF CONTENTS OPERATOR SPECIFICATIONS Carton Inventory . . 5 IMPORTANT NOTES · BEFORE attempting to install, operate or maintain the operator, you MUST read and fully understand this manual and follow all safety instructions. · DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician. OPERATOR WARNINGS Safety Installation Information . . 21 CAUTION WARNING WARNING Electrical WARNING CAUTION When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of SERIOUS INJURY or DEATH if you do not comply with the warnings that accompany them. [. . . ] There should be a black or other colored wire for hot, a white wire for neutral, and a green wire for earth ground. Receptacle STANDARD 115 VOLT HOOK-UP 1. When the wires have been connected to the receptacle, insert the receptacle back into the handy box (Figure 2). Apply the receptacle cover to the receptacle and secure it with a screw. To reduce the risk of electric shock, this equipment has a grounding type plug that has a third (grounding) pin. Figure 2 Knockout Flexible Conduit Handy Box CIA N ADVERTENCIA ADVERTENCIA Ground Receptacle Neutral Hot Power Cord 13 WIRING BATTERY BACKUP If the operator is already factory equipped with a battery backup, only the Right/Left Side switch and Mode 1 are supported (Figure 3). The Right/Left switch simply needs to be set in the same position as the Right/Left switch on the main control board (see page 22). Disconnect the brown and red wires from terminals 13 and 14 and insulate the ends of the wires. Attach 14 terminal charger board to terminal screws on the left side of control board and secure using terminal screws. Connect green wire from terminal 2 to terminal 15 of the control board. Connect orange wire from terminal D of the charger board to terminal 18 of the main control board. Connect red wire from terminal A to battery positive (+) and black wire from terminal B to battery negative (-) (Figure 4). Figure 3 (Set same as RIGHT/LEFT switch on control board. ) Figure 4 Disconnect these existing wires from 13 and 14. Existing Bridge Rectifier 14 WIRING CONTROL WIRING OPEN INPUT Any device that is used to open the gate from a closed position is an open input device. These open input terminals will cause the gate operator to open and/or close if the timer switch is in the OFF position. If the timer switch is in the ON position, these open input terminals will cause the gate operator to open and will hold the gate open until the input is released and the auto close time has elapsed. CLOSE INPUT Any device that is used to close the gate is a close input device. These close input terminals will cause the gate operator to close the gate any time the gate is in a non-closed position and can be used to override the timer and close the gate prematurely. SAFETY OPEN PULSE OPEN Any device that is used to stop the gate operator while it is running in the open or closed direction is a stop input device. To connect these normally closed contacts, remove the stop jumper from terminals 8 and 9 and then connect the contacts to these same terminals 8 and 9. SAFETY INPUT Any device that is used to open and/or hold open the gate while the gate is in a non-closed position is a safety input device. This function is especially useful when the auto close timer is being used in preventing the gate from accidentally closing on a vehicle. PULSE OPEN INPUT This input functions similarly to the standard open input with the exception that it will not hold the gate open if the input remains present. This feature will add additional security to the gate operator system in the event that there is a device that is stuck on. [. . . ] If no stop input device is installed make sure that there is a jumper between terminals 8 and 9 and that it is securely fastened. Make sure there is power to the circuit board on terminals 13 and 14. TROUBLESHOOTING SL930 TROUBLESHOOTING THE GATE WILL NOT STOP OR REVERSE WHEN IT MEETS AN OBSTRUCTION Adjust the gate sensitivity. This is done by turning the open and close gate sensitivity adjustments clockwise for more sensitivity (see page 22). Make sure that the Right/Left Side operation switch is in the correct position (see page 22). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN SL930




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN SL930 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.