[. . . ] INSTALLATION MANUAL
MODEL MT5011E/BMT5011E
MEDIUM DUTY DOOR OPERATOR
with Now lt in Bui ceiver e adio R R
I N TENDED INTENDED F O R P R O F ES S I O NA L E SSI I N STALLA TIO ON L INSTALLATI O N O NL Y
Visit www. LiftMaster. com to locate a professional installing dealer in your area.
Radio Receiver Built on Board
2 YEAR WARRANTY
Serial # (located on electrical box) Installation Date
315MHz
NOT FOR RESIDENTIAL USE
A SAFETY DEVICE IS HIGHLY RECOMMENDED.
TABLE OF CONTENTS
SAFETY INFORMATION . BACK COVER
SAFETY INFORMATION
WARNING WARNING
Mechanical
IMPORTANT NOTES:
CAUTION WARNING
Electrical
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. Read the warnings carefully.
· BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. · DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician.
WARNING
WARNING
WARNING
WARNING WARNING AVERTISSEMENT AVERTISSEMENT
2
CAUTION
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your door and/or the door operator if you do not comply with the cautionary statements that accompany it. [. . . ] The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. If the Monitored Safety Device is removed, the operator will go into a Restricted Close mode**. The operator will begin closing after a 5 second delay and will continue to close to the close limit switch. The operator will stop if the pressure to close is released before reaching the close limit.
WARNING CAUTION
To prevent possible SEVERE INJURY or DEATH, install reversing sensors when: · The radio is used. Reversing devices are recommended for ALL installations.
AVERTISSEMENT ATTENTION
B
C2 WIRING TYPE WITH MONITORED SAFETY DEVICE · Momentary contact to open and stop with constant pressure to close. · Open override that reverses when closing by any opening device. NOTE: The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) · Timer to Close (TTC) feature not available. MONITORED SAFETY DEVICE
A
C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE (Factory Default)
· Momentary contact to open and stop with constant pressure to close. · Open override that reverses when closing by any opening device. NOTE: The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) · Timer to Close (TTC) feature not available. NON-MONITORED SAFETY DEVICE
ADVERTENCIA PRECAUCIÓN
Sensing Edge Photo Eye
RESET TO C2 WIRING TYPE (Factory Default) Remove any monitored safety devices. Press and hold the LEARN and STOP buttons until the LED goes out (approximately 3 seconds).
Electrical Box Logic Board
TO PROGRAM Press and hold the LEARN and CLOSE buttons until the LED goes out (approximately 3 seconds).
Electrical Box Logic Board
D7 U4 D6
D5 D4
014A1030
TP1 C9 C21 C20
J4 C32 R25 U1
C31
L5
AUX ANT AUX ANT
J2
^^^^ C18 R27 D14 K2 LT C29 R24 P1
LEARN
LEARN STOP CLOSE OPEN
3 4 5 6 7 COM INTRLK STOP CLOSE OPEN
STOP
CLOSE OPEN
D7 U4 D6
D5 D4
TTC
LED
1 2
014A1030
TP1 C9 C21 C20
J4 C32 R25 U1
C31
D9 L5 ^^^^ C18 J2 R27 D14 K2 LT C29 R24 P1
LMEP1
LMEP2
AUX ANT AUX ANT
LEARN
LEARN STOP CLOSE OPEN
3 4 5 6 7 INTRLK STOP CLOSE OPEN
STOP
CLOSE OPEN 1
D14 LED
TTC
LED
1 2
D9
LMEP1
LMEP2
COM
D14 LED
2
3
4
5
6
7
1
2
3
4
5
6
7
18
BASIC PROGRAMMING
C
B2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE Requires a non-monitored safety device. · Open override that reverses when closing by any opening device. NOTE: The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) · Timer to Close (TTC) feature not available. NON-MONITORED SAFETY DEVICE
D
B2 WIRING TYPE WITH MONITORED SAFETY DEVICE · Momentary contact to open, close and stop. · Open override that reverses when closing by any opening device. NOTE: The operator will automatically convert to B2 wiring when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) · Timer to Close (TTC) feature available.
MONITORED SAFETY DEVICE
Sensing Edge
Photo Eye
TO PROGRAM Start with operator in factory default C2 mode. Press and hold the LEARN and CLOSE buttons until the LED goes out (approximately 3 seconds).
Electrical Box Logic Board
NO PROGRAMMING REQUIRED
D7 U4 D6
D5 D4
014A1030
TP1 C9 C21 C20
J4 C32 R25 U1
C31
L5
AUX ANT AUX ANT
J2
^^^^ C18 R27 D14 K2 LT C29 R24 P1
LEARN
LEARN STOP CLOSE OPEN
3 4 5 6 7 COM INTRLK STOP CLOSE OPEN
STOP
CLOSE OPEN
TTC
LED
1 2
D9
LMEP1
LMEP2
D14 LED
1
2
3
4
5
6
7
19
BASIC PROGRAMMING
REMOTE CONTROLS
SINGLE BUTTON REMOTE CONTROL Built in 315 MHz radio receiver permits as many as 20 Security® remote controls or dip switch remote controls in any combination. [. . . ] DIAGNOSTIC LED TABLE
# OF LED FLASHES 1 2 3 4 5 6 7 STATUS System OK. Operating in B2 mode Stuck CLOSE button Monitored Safety Device failure Incorrect motor direction Maximum run timer has timed out (Maximum run time = 90 seconds) Logic Board Failure FIX none none Check for stuck close button or shorted close wire Check for: 1) Misaligned or blocked photo eyes. NOTE: It is normal for the logic board LED to flash 7 times when power is applied or cycled to the operator. (Not a logic board failure. )
DIAGRAM
Green Brake (BMT only) Blue* Blue*
* If brake is not supplied,
wires are capped separately Black L2 Black L1
Capacitor Yellow
Yellow
Red
Red
OPEN
Motor
CLOSE
CLOSE OPEN
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
7
STOP
wires are capped together.
LEARN
Brown** Orange Purple Yellow
Grey
STOP
LED
2
3
4
5
** If interlock is not used,
Brown**
6
Remove Jumper to install external door interlock.
ANT
Safety Limit Switch
Open Limit Switch Grey
Close Limit Switch
23
AUX ANT
J2
TTC
1
REPAIR PARTS
ELECTRICAL BOX
4
K2
K3 K4
2
K1
K5
1
3
SERVICE KITS ITEM PART # K1 K72-33872-1 DESCRIPTION ITEM 1 2 3 4 PART # 13-10024 23-10041 29-10338 K10-33850
SERVICE KITS DESCRIPTION Limit Nut (1) Limit Switch (1) Capacitor Cover
Limit Switch Shaft Kit Complete with: Limit shaft, limit nuts, limit bearings, limit sprocket, washers, compression ring, roll pin and e-ring. [. . . ]