User manual CHAMBERLAIN MT5011E INTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN MT5011E. We hope that this CHAMBERLAIN MT5011E user guide will be useful to you.


CHAMBERLAIN MT5011E INTALLATION: Download the complete user guide (6434 Ko)

Manual abstract: user guide CHAMBERLAIN MT5011EINTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION MANUAL MODEL MT5011E/BMT5011E MEDIUM DUTY DOOR OPERATOR with Now lt in Bui ceiver e adio R R I N TENDED INTENDED F O R P R O F ES S I O NA L E SSI I N STALLA TIO ON L INSTALLATI O N O NL Y Visit www. LiftMaster. com to locate a professional installing dealer in your area. Radio Receiver Built on Board 2 YEAR WARRANTY Serial # (located on electrical box) Installation Date 315MHz NOT FOR RESIDENTIAL USE A SAFETY DEVICE IS HIGHLY RECOMMENDED. TABLE OF CONTENTS SAFETY INFORMATION . BACK COVER SAFETY INFORMATION WARNING WARNING Mechanical IMPORTANT NOTES: CAUTION WARNING Electrical When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. Read the warnings carefully. · BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. · DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician. WARNING WARNING WARNING WARNING WARNING AVERTISSEMENT AVERTISSEMENT 2 CAUTION When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your door and/or the door operator if you do not comply with the cautionary statements that accompany it. [. . . ] The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. If the Monitored Safety Device is removed, the operator will go into a Restricted Close mode**. The operator will begin closing after a 5 second delay and will continue to close to the close limit switch. The operator will stop if the pressure to close is released before reaching the close limit. WARNING CAUTION To prevent possible SEVERE INJURY or DEATH, install reversing sensors when: · The radio is used. Reversing devices are recommended for ALL installations. AVERTISSEMENT ATTENTION B C2 WIRING TYPE WITH MONITORED SAFETY DEVICE · Momentary contact to open and stop with constant pressure to close. · Open override that reverses when closing by any opening device. NOTE: The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) · Timer to Close (TTC) feature not available. MONITORED SAFETY DEVICE A C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE (Factory Default) · Momentary contact to open and stop with constant pressure to close. · Open override that reverses when closing by any opening device. NOTE: The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) · Timer to Close (TTC) feature not available. NON-MONITORED SAFETY DEVICE ADVERTENCIA PRECAUCIÓN Sensing Edge Photo Eye RESET TO C2 WIRING TYPE (Factory Default) Remove any monitored safety devices. Press and hold the LEARN and STOP buttons until the LED goes out (approximately 3 seconds). Electrical Box Logic Board TO PROGRAM Press and hold the LEARN and CLOSE buttons until the LED goes out (approximately 3 seconds). Electrical Box Logic Board D7 U4 D6 D5 D4 014A1030 TP1 C9 C21 C20 J4 C32 R25 U1 C31 L5 AUX ANT AUX ANT J2 ^^^^ C18 R27 D14 K2 LT C29 R24 P1 LEARN LEARN STOP CLOSE OPEN 3 4 5 6 7 COM INTRLK STOP CLOSE OPEN STOP CLOSE OPEN D7 U4 D6 D5 D4 TTC LED 1 2 014A1030 TP1 C9 C21 C20 J4 C32 R25 U1 C31 D9 L5 ^^^^ C18 J2 R27 D14 K2 LT C29 R24 P1 LMEP1 LMEP2 AUX ANT AUX ANT LEARN LEARN STOP CLOSE OPEN 3 4 5 6 7 INTRLK STOP CLOSE OPEN STOP CLOSE OPEN 1 D14 LED TTC LED 1 2 D9 LMEP1 LMEP2 COM D14 LED 2 3 4 5 6 7 1 2 3 4 5 6 7 18 BASIC PROGRAMMING C B2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE Requires a non-monitored safety device. · Open override that reverses when closing by any opening device. NOTE: The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) · Timer to Close (TTC) feature not available. NON-MONITORED SAFETY DEVICE D B2 WIRING TYPE WITH MONITORED SAFETY DEVICE · Momentary contact to open, close and stop. · Open override that reverses when closing by any opening device. NOTE: The operator will automatically convert to B2 wiring when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) · Timer to Close (TTC) feature available. MONITORED SAFETY DEVICE Sensing Edge Photo Eye TO PROGRAM Start with operator in factory default C2 mode. Press and hold the LEARN and CLOSE buttons until the LED goes out (approximately 3 seconds). Electrical Box Logic Board NO PROGRAMMING REQUIRED D7 U4 D6 D5 D4 014A1030 TP1 C9 C21 C20 J4 C32 R25 U1 C31 L5 AUX ANT AUX ANT J2 ^^^^ C18 R27 D14 K2 LT C29 R24 P1 LEARN LEARN STOP CLOSE OPEN 3 4 5 6 7 COM INTRLK STOP CLOSE OPEN STOP CLOSE OPEN TTC LED 1 2 D9 LMEP1 LMEP2 D14 LED 1 2 3 4 5 6 7 19 BASIC PROGRAMMING REMOTE CONTROLS SINGLE BUTTON REMOTE CONTROL Built in 315 MHz radio receiver permits as many as 20 Security® remote controls or dip switch remote controls in any combination. [. . . ] DIAGNOSTIC LED TABLE # OF LED FLASHES 1 2 3 4 5 6 7 STATUS System OK. Operating in B2 mode Stuck CLOSE button Monitored Safety Device failure Incorrect motor direction Maximum run timer has timed out (Maximum run time = 90 seconds) Logic Board Failure FIX none none Check for stuck close button or shorted close wire Check for: 1) Misaligned or blocked photo eyes. NOTE: It is normal for the logic board LED to flash 7 times when power is applied or cycled to the operator. (Not a logic board failure. ) DIAGRAM Green Brake (BMT only) Blue* Blue* * If brake is not supplied, wires are capped separately Black L2 Black L1 Capacitor Yellow Yellow Red Red OPEN Motor CLOSE CLOSE OPEN LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN 7 STOP wires are capped together. LEARN Brown** Orange Purple Yellow Grey STOP LED 2 3 4 5 ** If interlock is not used, Brown** 6 Remove Jumper to install external door interlock. ANT Safety Limit Switch Open Limit Switch Grey Close Limit Switch 23 AUX ANT J2 TTC 1 REPAIR PARTS ELECTRICAL BOX 4 K2 K3 K4 2 K1 K5 1 3 SERVICE KITS ITEM PART # K1 K72-33872-1 DESCRIPTION ITEM 1 2 3 4 PART # 13-10024 23-10041 29-10338 K10-33850 SERVICE KITS DESCRIPTION Limit Nut (1) Limit Switch (1) Capacitor Cover Limit Switch Shaft Kit Complete with: Limit shaft, limit nuts, limit bearings, limit sprocket, washers, compression ring, roll pin and e-ring. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN MT5011E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN MT5011E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.