User manual CHAMBERLAIN MJ

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN MJ. We hope that this CHAMBERLAIN MJ user guide will be useful to you.


CHAMBERLAIN MJ : Download the complete user guide (2899 Ko)

You may also download the following manuals related to this product:

   CHAMBERLAIN MJ QUICK START (2071 ko)

Manual abstract: user guide CHAMBERLAIN MJ

Detailed instructions for use are in the User's Guide.

[. . . ] FACTORY SET OWNER'S MANUAL MODELS: C2 Wiring See page 8 for other wiring configurations MJ MH HMJ INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 SPECIFICATIONS MOTOR TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intermittent duty HORSEPOWER: . . . . . . . . . . . . . . . . 1/2 HP SPEED:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 RPM VOLTAGE: . . . . . . . . . . . . . . . . . . . . . . . . . . 115V 1 Phase 60Hz, 230V 1 Phase 50Hz CURRENT:. . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate ELECTRICAL TRANSFORMER:. . . . . . . . . . . . . 24Vac CONTROL STATION: . . . . . . NEMA 1 3-button station. OPEN/CLOSE/STOP WIRING TYPE:. . . . . . . . . . . . . . . . . C2 (Standard) Momentary contact to OPEN & STOP, constant pressure to CLOSE, open override plus wiring for sensing device to reverse. See pages 13 and 14 for optional control settings and operating modes. LIMIT ADJUST: . . . . . . . . . . . . . . . . Linear driven, fully adjustable screw type cams. [. . . ] After adjustment, release plate and ensure it seats fully in slots of both nuts. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. Adjust close limit nut so that actuator is engaged as door fully seats at the floor. WARNING CAUTION WARNING WARNING To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect electric power BEFORE manually moving limit nuts. If other problems persist, call our toll-free number for assistance - 1-800-528-2806. OPEN Limit Switch Retaining Plate CLOSE Limit Switch Aux. Close) Limit Switch 6 WARNING WARNING POWER WIRING POWER WIRING CONNECTIONS 1. Inside this enclosure you will find the wiring diagram(s) for your unit. Refer to the diagram (glued on the inside of the cover) for all connections described below. If this diagram is missing, call the number on the back of this manual. DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM. Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Using the 1-1/16" dia conduit access hole as shown below, bring supply lines to the operator and connect wires to the terminals indicated on the WIRING CONNECTIONS DIAGRAM. Important NOTE: Connect earth ground to the chassis ground screw in the electrical box enclosure. Do not turn power on until you have finished making all power and control wiring connections and have completed the limit switch adjustment procedure. To reduce the risk of SEVERE INJURY or DEATH: · ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. Reversing devices are recommended for ALL installations. CAUTION Momentary contact on close (B2 wiring) Move RED wire from terminal block #12 to terminal #2. The operator will require only momentary contact to close the door. SPECIAL CONTROL WIRING If your operator was shipped from the factory with non-standard control wiring or with optional accessories that require addition instructions, refer to the wiring diagram(s) indicated in the special control wiring data box. When a replacement wiring diagram is present, wiring diagrams in this manual will not apply. Refer only to the replacement wiring diagram for all connections. SPECIAL CONTROL WIRING DATA This Operator has Control Wiring. SUPPLEMENTAL WIRING DIAGRAM(S) WIRING REPLACEMENT WIRING DIAGRAM Wiring Type Note: Supplemental Wiring Diagrams are to be used in addition to 1753 or 1754. Replacement Wiring Diagram is to be used in place of 1753 or 1754. Wiring Diagram label on inside cover of electrical box LOCATING THE CONTROL STATION All operators are supplied with some type of control station. A two-position key switch or control station (OPEN/CLOSE) may be added or substituted when requested at the time of order. Mount the control station near the door. MOUNT WARNING NOTICE IMPORTANT: Mount WARNING NOTICE beside or below the push button station. Control Station OPEN Push Buttons WARNING CLOSE SE TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR STOP WARNING Notice 8 CONTROL WIRING (cont'd) WARNING Install the control station and receiver where the door is visible, but away from the door and its hardware. When a receiver is used to activate a commercial door opener, a reversing edge MUST be installed on the bottom of the door. Failure to install a reversing edge under these circumstances may result in SERIOUS INJURY or DEATH to persons trapped beneath the door. WARNING WARNING To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door: · ALWAYS keep remote controls out of reach of children. [. . . ] Lubricate. * Check set screw tightness Check & adjust as required Check condition & tension Check & tighten as required Check & Operate Check for wear & lubricate Sprockets Clutch Belt Fasteners Manual Disconnect Bearings & Shafts WARNING CAUTION WARNING WARNING Use SAE 30 Oil (Never use grease or silicone spray). Inspect and service whenever a malfunction is observed or suspected. To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric power BEFORE performing ANY maintenance. HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA Installation and service information is available CALL OUR TOLL FREE number: 1-800-528-2806 WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION: PART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP, INC. Country Club Tucson, AZ 85706 11 SCHEMATIC DIAGRAM 1754 (OPTIONAL) (OPTIONAL) W LIGHT MAX. 100W C BIMETAL RELAY B BK A W Y CLOSE-B C W N. O. BL RES. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN MJ




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN MJ will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.