User manual CHAMBERLAIN MGJ5011E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN MGJ5011E. We hope that this CHAMBERLAIN MGJ5011E user guide will be useful to you.


CHAMBERLAIN MGJ5011E : Download the complete user guide (3932 Ko)

Manual abstract: user guide CHAMBERLAIN MGJ5011E

Detailed instructions for use are in the User's Guide.

[. . . ] Reversing devices are recommended for ALL installations. AVERTISSEMENT B C2 WIRING TYPE WITH MONITORED SAFETY DEVICE A C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE (Factory Default) ATTENTION · Momentary contact to open and stop with constant pressure to close. · Open override that reverses when closing by any opening device. NOTE: The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) · Timer to Close (TTC) feature not available. [. . . ] MONITORED SAFETY DEVICE NON-MONITORED SAFETY DEVICE Sensing Edge Photo Eye TO PROGRAM Start with operator in factory default C2 mode. Press and hold the LEARN and CLOSE buttons until the LED goes out (approximately 3 seconds). Electrical Box Logic Board NO PROGRAMMING REQUIRED D7 U4 D6 D5 D4 014A1030 TP1 C9 C21 C20 J4 C32 R25 U1 C31 L5 AUX ANT AUX ANT J2 ^^^^ C18 R27 D14 K2 LT C29 R24 P1 LEARN LEARN STOP CLOSE OPEN 3 4 5 6 7 COM INTRLK STOP CLOSE OPEN STOP CLOSE OPEN TTC LED 1 2 D9 LMEP1 LMEP2 D14 LED 1 2 3 4 5 6 7 3 BASIC PROGRAMMING REMOTE CONTROLS SINGLE BUTTON REMOTE CONTROL Built in 315 MHz radio receiver permits as many as 20 Security® remote controls or dip switch remote controls in any combination. Press and hold the button on the remote control until the LED flashes rapidly, then release to complete programming (LED will go out). Repeat steps 1 and 2 for additional remote controls. Electrical Box Logic Board TIMER TO CLOSE (TTC) Timer to Close feature enables the operator to close from the open limit after a preset time, adjustable from 5 to 60 seconds. Every press and release of the STOP button will add 5 seconds to the Timer to Close. The TTC will become active after completion of the next open cycle. NOTE: The LED does not indicate that timer is running. 1 2 3 4 5 OPEN LEARN D14 LED D7 U4 D6 D5 D4 STOP CLOSE OPEN 014A1030 TP1 C9 C21 C20 J4 C32 R25 U1 C31 L5 AUX ANT AUX ANT J2 ^^^^ C18 R27 D14 K2 LT C29 R24 P1 TTC LED 1 2 LEARN STOP CLOSE OPEN 3 4 5 6 7 6 7 D9 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN TO VERIFY TIMER TO CLOSE (TTC) SETTING 1. The LED will flash once per 5 seconds of timer setting. Electrical Box Logic Board Timer To Close Button MEP1 LMEP2 COM INTRLK STOP CLOSE OPEN 3-BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3-BUTTON CONTROL STATION NOTE: The feature will use 3 of the 20 memory channels in the operator. TTC D14 LED D7 U4 D6 D5 D4 LEARN STOP CLO TO PROGRAM Open 1. Press and hold the desired button of the remote control until LED flashes rapidly, then release. TO ERASE ALL REMOTE CONTROLS Press and hold the LEARN button (over 5 seconds) until the LED goes out. All programmed remote controls will be erased. Electrical Box Logic Board 014A1030 TP1 C9 C21 C20 J4 C32 R25 U1 C31 L5 AUX ANT AUX ANT J2 ^^^^ C18 R27 D14 K2 LT C29 R24 P1 1 LEARN STOP CLOSE OPEN 3 4 5 6 7 COM INTRLK STOP CLOSE OPEN 2 3 4 5 TTC LED 1 2 D9 LMEP1 LMEP2 LMEP1 LMEP2 COM INTRLK STOP CL CLEAR THE TIMER TO CLOSE (TTC) 1. TIMER DEFEAT The TTC can be temporarily disabled by pressing a STOP button. TTC will become enabled after the next open command. RADIO OPERATION MODE OPEN CLOSE STOP REVERSE WHILE CLOSING TTC RESET LEARN D14 LED D7 U4 D6 D5 D4 STOP CLOSE OPEN 014A1030 TP1 C9 C21 C20 J4 C32 R25 U1 C31 L5 AUX ANT AUX ANT J2 ^^^^ C18 R27 D14 K2 LT C29 R24 P1 TTC LED 1 2 LEARN STOP CLOSE OPEN 3 4 5 6 7 1 2 3 4 5 6 7 D9 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN MEP1 LMEP2 COM INTRLK STOP CLOSE OPEN NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. B2 B2 with TTC C2 X X X X X (3 button remote) X X X X X X X WHEN OPEN 4 WARNING MANUAL DISCONNECT (MODELS MT/BMT & MH) The operators have provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions for your model operator. CAUTION To prevent possible SERIOUS INJURY or DEATH from a falling door or arm: · DO NOT stand under the door arm when pulling the emergency release. · If possible, use emergency release handle to disengage trolley ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/ or unexpectedly. · NEVER use emergency release handle unless doorway is clear of persons and obstructions. MODEL MT/BMT Emergency Disconnect TO DISCONNECT DOOR FROM OPENER AVERTISSEMENT ATTENTION Emergency Disconnect Door Arm TO RECONNECT DOOR ARM TO TROLLEY Lift free end of door arm to trolley. Emergency disconnect will close. Emergency Disconnect Door Arm NOTI C E Pull emergency release handle straight down. Emergency disconnect will open. Door Emergency Release Handle MODEL MH These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used. [. . . ] Contact your installing dealer. MAINTENANCE SCHEDULE Every 3 months or 5, 000 cycles repeat all tests in the Testing section. To locate a dealer in your area visit us online at www. liftmaster. com. The operator should be serviced at the following intervals: · Every 3 months or 5, 000 cycles · Every 6 months or 10, 000 cycles · Every 12 months or 20, 000 cycles WARNING To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric power BEFORE performing ANY maintenance. CAUTION AVERTISSEMENT 8 ATTENTION O P E R AT O R N O T E S 9 O P E R AT O R N O T E S 10 O P E R AT O R N O T E S 11 OPEN OPEN ACCESSORIES ENTRAPMENT PROTECTION DEVICES REMOTE CONTROLS 315MHz 371LM OPEN 1-Button SECURITY® Remote Control: Includes visor clip. Monitored CPS-LN4 PRESS Commercial Protector System®: Provides protection on doors up to 45' wide. NEMA-4 rated. OPEN R ING TO 373LM 3-Button SECURITY® Remote Control: Includes visor clip. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN MGJ5011E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN MGJ5011E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.