[. . . ] INSTALLATION/OPERATION MANUAL
MODEL LA400
MEDIUM DUTY SWING GATE OPERATOR
Radio Receiver Built on Board
315MHz
2 YEAR WARRANTY
Serial # Primary Arm Serial # Secondary Arm Serial # Control Box Installation Date
TABLE OF CONTENTS
Introduction 2-5
Carton Inventory . . 33
Operation
34
Overview of Typical Installation
6-10
Reset Button . . 7 Safety Precautions for Swing and Ornamental "Grill Type Gates" . . 10
Maintenance Basic Control Board Layout Wiring Diagram Troubleshooting Repair Parts LA400 Swing Gate Accessories Warranty Policy and Service
35-36 37 38 39-40 41-42 43 44
Battery Replacement . [. . . ] The Save switch must be set to the OFF position prior to programming or changing the switches. NOTE: Save switch must be in the OFF position prior to programming or changing switches for the change to be saved.
O N
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345
S1
FACTORY DEFAULT SHOWN
P2
J19
Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE
J1
CLOSE EDGE
OPEN/EGE PHOTO
L1
1
O N
S8
LEARN XMITTER
2
OFF OFF SINGLE NO NO
S1
ON SAVE ON MAGLOCK DUAL MODE NC EDGE NC PHOTO
12345
OPEN PHOTO
CLOSE PHOTO
GATE1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
24V
GATE 2
OVLD
SWITCHED ACCESSORY POWER
GATE 1
GATE 1 AND GATE 2
O N
O N
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
24
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
12345
12345
Step 2: Program Limits (Ensure Save Switch is in the OFF position before beginning)
DIAGNOSTIC
1. With the gate in the closed position, press the "LEARN LIMITS" button. The "SET OPEN LIMIT" LED will blink.
GATE 1
SET T EN N OPEN T LIMIT
SET CLOSE LIMIT
LEARN LIMITS
GATE 2
FORCE
LEARN LIMITS Button
DIAGNOSTIC
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
2. Use the "Gate 1" buttons to move Gate 1 to the desired open position (not to exceed 100°). If you have gone beyond the desired open position you can jog the gate towards the close position by using the opposite Gate 1 button. Repeat if Gate 2 is present using the "Gate 2" buttons.
DIAGNOSTIC
DIAGNOSTIC
GATE 1
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
GATE 2
GATE 2
FORCE
FORCE
GATE 2
DIAGNOSTIC
P2 J19 Ø14GP 89ØE 14GPØ89 Ø14LG 89ØE 14LGØ89 Ø14SK 89ØE 14SKØ89 J1
CLOSE EDGE
OPEN/EGE PHOTO
L1
FORCE
1
S8
LEARN XMITTER
2
OFF OFF SINGLE NO NO
ON SAVE ON MAGLOCK DUAL MODE EDGE NC PHOTO NC
OPEN PHOTO
S1
CLOSE PHOTO
GATE1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
24V
GATE 2
OVLD
SWITCHED ACCESSORY POWER
SINGLE BUTTON
3. Press the "LEARN LIMITS" button again to set the Open position. The "SET CLOSE LIMIT" LED will blink and beep once.
GATE 1
O N
12345
SET OPEN LIMIT
SET S CLO C CLOSE L LIMIT
LEARN LIMITS
GATE 2
FORCE
4. Use the "Gate 1" buttons to move Gate 1 to the desired close position. If you have gone beyond the desired closed position you can jog the gate towards the open position by using the opposite Gate 1 button. Repeat if Gate 2 is present using the "Gate 2" buttons.
DIAGNOSTIC
DIAGNOSTIC
GATE 1
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
GATE 2
GATE 2
FORCE
FORCE
DIAGNOSTIC
SINGLE BUTTON O SINGLE B
5. Press the "LEARN LIMITS" button again to set the Closed position. The limits are now set.
GATE 1
SET OPEN LIMIT
SET S CL C CLOSE L LIMIT
LEARN LIMITS
GATE 2
FORCE
6. Using the single button control on the board, run the gate(s) from the closed position to the open position. This will learn the forces.
O N
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345
S1
7. Set Save Switch to the ON position.
25
Step 3: Set Force / Bi-Part / Timer
P2
J19 Ø14GP 89ØE 14GPØ89 Ø14LG 89ØE 14LGØ89 Ø14SK 89ØE 14SKØ89 J1
CLOSE EDGE
BI-PART DELAY Control
OPEN/EGE PHOTO
L1
1
O N
S8
LEARN XMITTER
2
OFF OFF SINGLE NO NO
ON SAVE ON MAGLOCK DUAL MODE EDGE NC PHOTO NC
12345 S1
OPEN PHOTO
CLOSE PHOTO
FORCE Control
SET OPEN LIMIT
24V
OVLD
SWITCHED ACCESSORY POWER
FORCE
BIPART DELAY
TIMER TO CLOSE
TIMER TO CLOSE Control
FORCE
BI-PART DELAY
TIMER TO CLOSE
Z9
Z8
MIN
MAX
OFF
MAX
OFF
MAX
FORCE CONTROL Set the force control such that the opener will complete a full cycle of gate travel but will reverse off an obstruction without applying an excessive amount of force.
BI-PART DELAY Set the BI-PART DELAY to desired setting. NOTE: Used for Dual Gate installations only.
TIMER TO CLOSE ENABLE Set the TIMER TO CLOSE to desired setting. The range is 0 to 180 seconds, 0 seconds is OFF.
FORCE
BI-PART DELAY
TIMER TO CLOSE
Minimun Force
Maximum Force
OFF
MAX
OFF
MAX
Your basic installation is now complete. 26
OPTIONAL CONTROL AND SAFETY DEVICES
To Add or Reprogram a Remote Control
1. Press and release "LEARN XMITTER" button (LED will light up). Press and hold remote button, the LED will flash, alarm will beep twice and the LED will go out. [. . . ] Requires separate power supply (Model ARMPS).
OPEN
50-19509 86LM Remote Antenna Mounting Kit: Kit contains antenna bracket and 15' (4. 6 m) of cable. 50-19511 50-19512 GCPSN4
6" Post Mounting Kit for control box 4" Post Mounting Kit for control box 2 1/2" Post Mounting Kit for control box Commercial Protector System®: Maximum range is 45' 24V. Commercial Protector System® (Direct Connect): Maximum range is 45' 24V. Includes mounting hardware.
CPS-LN4
43
WARRANTY POLICY AND SERVICE
LIFTMASTER® TWO YEAR LIMITED WARRANTY
The Chamberlain Group, Inc. [. . . ]