[. . . ] FACTORY SET
C2 Wiring
See page 8 for other wiring configurations
OWNER'S MANUAL
MODEL GT
INDUSTRIAL DUTY DOOR OPERATOR
2 YEAR WARRANTY
Serial # (located on electrical box cover) Installation Date Wiring Type
NOT FOR RESIDENTIAL USE
41B6
LISTED DOOR OPERATOR
SPECIFICATIONS
MOTOR
TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous duty HORSEPOWER:. . . . . . . . . . . . . . . . . 1/2, 3/4, 1 & 1-1/2 Hp Single or Three phase SPEED:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1725 RPM VOLTAGE: . . . . . . . . . . . . . . . . . . . . . . . . . . 115, 220, 230 Single phase 230, 460, 575 Three phase CURRENT: . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate
ELECTRICAL
TRANSFORMER:. . . . . . . . . . . . . 24VAC CONTROL STATION: . . . . . . NEMA 1 three button station. OPEN/CLOSE/STOP WIRING TYPE: . . . . . . . . . . . . . . . . . C2 (Factory Shipped) Momentary contact to OPEN & STOP, constant pressure to CLOSE, open override plus wiring for sensing device to reverse. LIMIT ADJUST: . . . . . . . . . . . . . . . . Linear driven, fully adjustable screw type cams. Adjustable to 24 feet.
MECHANICAL
DRIVE REDUCTION:. . . . . . . . . . . . . Primary: Heavy duty wormgear-in-oil-bath speed reducer. [. . . ] Adjust close limit nut so that actuator is engaged as door fully seats at the floor.
WARNING
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS.
If other problems persist, call our toll-free number for assistance - 1-800-528-2806.
CLOSE Limit Switch OPEN Limit Switch
Actuator
Retaining Plate
Aux. Close) Limit Switch
POWER WIRING CONNECTIONS
Remove the cover from the electrical enclosure. Inside this enclosure you will find the wiring diagram(s) for your unit. Refer to the diagram (glued on the inside of the cover) for all connections described below. If this diagram is missing, call the number on the back of this manual. DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM.
NING
WARNING
DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND PERMANENTLY WIRED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. NOTE: THE OPERATOR SHOULD BE ON A SEPARATE FUSED LINE OF ADEQUATE CAPACITY. ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL.
POWER WIRING
1. Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Using the 1-1/16" dia conduit access knockout as shown below, bring supply lines to the operator and connect wires to the terminals indicated on the WIRING CONNECTIONS DIAGRAM. DO NOT TURN POWER ON UNTIL YOU HAVE FINISHED MAKING ALL POWER AND CONTROL WIRING CONNECTIONS AND HAVE COMPLETED THE LIMIT SWITCH ADJUSTMENT PROCEDURE.
TION
WARNING
WARNING
TO AVOID DAMAGE TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH.
WARNING
IMPORTANT: THIS UNIT MUST BE PROPERLY GROUNDED. A GROUND SCREW IS SUPPLIED IN THE ELECTRICAL BOX FOR CONNECTION OF THE POWER SUPPLY GROUND WIRE. FAILURE TO PROPERLY GROUND THIS UNIT COULD RESULT IN ELECTRIC SHOCK AND SERIOUS INJURY.
CAUTION
WARNING
ON THREE PHASE MACHINES ONLY!A two-position key switch or control station (OPEN/CLOSE) may be added or substituted when requested at the time of order. Mount the control station near the door.
MOUNT WARNING NOTICE
WARNING
INSTALL THE CONTROL STATION WHERE THE DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING EDGE MUST BE INSTALLED ON THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A REVERSING EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR.
IMPORTANT: Mount WARNING NOTICE beside or below the push button station.
Standard Control Station
OPEN
Push Buttons
WARNING
CLOSE
TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR
STOP
WARNING Notice
8
CONTROL WIRING (con't)
Radio Controls On all models with type B2 control wiring, a terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. All standard radio control receivers (single channel residential type) may be mounted to this bracket. The operator will then open a fully closed door, close a fully open door, and reverse a closing door from the radio transmitter. However, for complete door control from a transmitter, a commercial three-channel radio set (with connections for OPEN/CLOSE/STOP) is recommended.
WARNING
DO NOT USE RADIO CONTROLS WITH YOUR OPERATOR UNLESS YOU HAVE INSTALLED SOME TYPE OF ENTRAPMENT PROTECTION DEVICE. [. . . ] OPEN LIMIT SWITCH
NO (PUR)
(OR)
R1
CLOSE
R2
2
TIMER TO CLOSE (OPTIONAL)
(PUR)
(PUR) 14
(PUR)
R1
(PUR) (PUR) CL A2 A1
CLOSE LIMIT SWITCH
NC C
(PUR)
(PUR) (RED)
CL
(RED) 13
CLOSE CONTROL WIRING OPTIONS
*-
Shipped from Factory
*C2 WIRING
- Constant Presssure to Close RED WIRE ON TERMINAL #2 (Shipped from Factory) B2 WIRING - Momentary Contact to Close MOVE RED WIRE FROM TERMINAL #2 TO TERMINAL #3
NOTE: 1. Overload in motor for models up to 3/4 Hp, located in limit box for 1 Hp and above.
14
THREE PHASE WIRING DIAGRAM
1742-3
R1
ORANGE YELLOW RED RED YELLOW
TO TERMINAL #2 PURPLE PURPLE TO TERMINAL #3
RADIO RECEIVER
R2 R3
AUX. TERMINAL BLOCK FOR RADIO
TIMER
( OPTIONAL )
GREY
C
C
AUX. OPEN L/S
NO NC
PURPLE ORANGE
GREY
NC
SAFETY L/S
OPEN LIMIT SWITCHES
OPEN L/S
NC C
CLOSE LIMIT SWITCHES
PURPLE PURPLE BLACK NC C CLOSE L/S
ORANGE ORANGE
PURPLE RED YELLOW GREY PURPLE
A1 13 5 3 1
CLOSE
A2 14 6 4 2
PURPLE PURPLE PURPLE BLACK BLACK
BROWN LOAD 24VAC YELLOW
**LINE
XFMR
BLACK
WHITE ORANGE ORANGE A1 13 5 3 1 OPEN A2 14 6 4 2 ORANGE YELLOW BLACK BLACK BLACK
WIRE NUT
( 3/4 HP & BELOW)
BROWN RED PURPLE PURPLE
T1 T2 T3 BROWN BROWN 96 95
L1 L2 L3
YELLOW
R1 RELAY
C NO NC
GREY
ORANGE ORANGE RED ( 3/4 HP & BELOW ) PURPLE ( 1 HP & ABOVE )
OVERLOAD
( 1 HP & ABOVE ONLY )
*SEE NOTE:
INTERLOCK
RED ORANGE GREY ORANGE PURPLE PURPLE RED ORANGE YELLOW ORANGE BROWN BROWN BLACK BLACK
230V. BRAKE SOLENOID ( WHEN REQUIRED )
BL-BK
BROWN
BROWN
BR BR P Y 2 3 8 9 5 6
J
OVERLOAD
J
(UP TO 3/4 HP)
GY
1
7
4
1
2
3
4
5
7
10
L1 L2
L3
GROUND
BL-BK
TO MOTOR
230V. BRAKE SOLENOID ( WHEN REQUIRED )
BL-BK
BLACK
GREY
( 3/4 HP & BELOW )
( OPTIONAL )
ORANGE YELLOW YELLOW
BL-BK BL-BK
BR BR
J
P Y
2 3
8 9
5 6 J
OVERLOAD (UP TO 3/4 HP)
GY
1
7
4
OPEN CLOSE
EXT. [. . . ]