User manual CHAMBERLAIN GH 2000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN GH. We hope that this CHAMBERLAIN GH user guide will be useful to you.


CHAMBERLAIN GH 2000: Download the complete user guide (3687 Ko)

You may also download the following manuals related to this product:

   CHAMBERLAIN GH 2009 (2681 ko)
   CHAMBERLAIN GH LOGIC 3 2009 (3023 ko)
   CHAMBERLAIN GH SOLID STATE 1997 (4506 ko)
   CHAMBERLAIN GH REPLACEMENT PARTS (1700 ko)
   CHAMBERLAIN GH LOGIC CONTROL V2.0 (2625 ko)

Manual abstract: user guide CHAMBERLAIN GH2000

Detailed instructions for use are in the User's Guide.

[. . . ] FACTORY SET C2 Wiring See page 8 for other wiring configurations OWNER'S MANUAL MODEL GH INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 LISTED DOOR OPERATOR SPECIFICATIONS MOTOR TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous duty HORSEPOWER:. . . . . . . . . . . . . . . . . 1/2, 3/4, 1 & 1-1/2 Hp Single or Three phase 2 HP Three phase SPEED:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1725 RPM VOLTAGE: . . . . . . . . . . . . . . . . . . . . . . . . . . 115, 220, 230 Single phase 230, 460, 575 Three phase CURRENT: . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate ELECTRICAL TRANSFORMER:. . . . . . . . . . . . . 24VAC CONTROL STATION: . . . . . . NEMA 1 three button station. OPEN/CLOSE/STOP WIRING TYPE: . . . . . . . . . . . . . . . . . C2 (Standard) Momentary contact to OPEN/CLOSE/STOP plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. 8) LIMIT ADJUST: . . . . . . . . . . . . . . . . Linear driven, fully adjustable screw type cams. Adjustable to 30 feet. MECHANICAL DRIVE REDUCTION:. . . . . . . . . . . . . 40:1 Reduction Heavy duty bronze worm gear reducer OUTPUT SHAFT SPEED: . . . . . 43 R. P. M. [. . . ] Refer to the diagram (glued on the inside of the cover) for all connections described below. If this diagram is missing, call the number on the back of this manual. DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM. POWER WIRING 1. Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Using the 1-1/16" dia conduit access knockout as shown below, bring supply lines to the operator and connect wires to the terminals indicated on the WIRING CONNECTIONS DIAGRAM. WARNING WARNING DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND CONNECTED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. Replacement Wiring Diagram is to be used in place of 1742-1. Wiring Diagram label on inside cover of electrical box SPECIAL CONTROL WIRING If your operator was shipped from the factory with non-standard control wiring or with optional accessories that require addition instructions, refer to the wiring diagram(s) indicated in the special control wiring data box. When a replacement wiring diagram is present, wiring diagrams in this manual will not apply. Refer only to the replacement wiring diagram for all connections. IMPORTANT NOTE: If your wiring diagram is missing, or you are unsure of the wiring type for your operator, contact the customer service department @ 1-800-528-2806. LOCATING THE CONTROL STATION All operators are supplied with some type of control station. A two-position key switch or control station (OPEN/CLOSE) may be added or substituted when requested at the time of order. Mount the control station near the door. WARNING INSTALL THE CONTROL STATION WHERE THE DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING EDGE MUST BE INSTALLED ON THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A REVERSING EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR. MOUNT WARNING NOTICE IMPORTANT: Mount WARNING NOTICE beside or below the push button station. Standard Control Station OPEN Push Buttons WARNING CLOSE TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR STOP WARNING Notice 8 CONTROL WIRING (con't) Radio Controls On all models with type B2 control wiring, a terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. All standard radio control receivers (single channel residential type) may be mounted to this bracket. The operator will then open a fully closed door, close a fully open door, and reverse a closing door from the radio transmitter. However, for complete door control from a transmitter, a commercial three-channel radio set (with connections for OPEN/CLOSE/STOP) is recommended. WARNING DO NOT USE RADIO CONTROLS WITH YOUR OPERATOR UNLESS YOU HAVE INSTALLED SOME TYPE OF ENTRAPMENT PROTECTION DEVICE. THE USE OF RADIO CONTROLS PRESENTS POTENTIAL HAZARDS DUE TO THE USER'S ABILITY TO OPEN OR CLOSE THE DOOR WHEN OUT OF SIGHT OF THE DOOR. IN ADDITION, IF A SINGLE CHANNEL CONTROL IS USED, THE USER WILL NOT BE ABLE TO STOP THE DOOR FROM THE TRANSMITTER. W CAUTION Additional Access Control Equipment Locate any additional access control equipment as desired (but so that the door will be in clear sight of the person operating the equipment), and connect to the terminal block in the electrical enclosure as shown on the FIELD WIRING CONNECTIONS diagram. Any control with a normally (N. O. ) isolated output contact may be connected in parallel with the OPEN button. DO NOT USE THE CONTROL CIRCUIT TRANSFORMER (24VAC) IN THE OPERATOR TO POWER ANY ACCESS CONTROL EQUIPMENT OTHER THAN A STANDARD RESIDENTIAL TYPE RADIO RECEIVER. External Interlock Switch The operator has a terminal connection for an external interlock switch. This switch must be a normally closed (N. C. ) two-wire device with a contact rating of at least 3 amps @ 24VAC. When such a switch is connected as shown on the FIELD WIRING CONNECTIONS diagram, the control circuit will be disabled when the switch is actuated, thereby preventing electrical operation of the door from the control devices. CLUTCH ADJUSTMENT (OPTIONAL MODIFICATION) 1. [. . . ] BRAKE SOLENOID ( WHEN REQUIRED ) BL-BK BLACK GREY ( 3/4 HP & BELOW ) ( OPTIONAL ) ORANGE YELLOW YELLOW BL-BK BL-BK BR BR J P Y 2 3 8 9 5 6 J OVERLOAD (UP TO 3/4 HP) GY 1 7 4 OPEN CLOSE EXT. TO OPEN AND CLOSE *L1 L2 L3 Shipped from Factory CLOSE CONTROL WIRING OPTIONS BRAKE ( WHEN REQ'D ) * C2 WIRING: Constant Presssure to Close RED WIRE ON TERMINAL #2 (Shipped from Factory) B2 WIRING: Momentary Contact to Close MOVE RED WIRE FROM TERMINAL #2 TO TERMINAL #3 BL-BK 460V. BRAKE SOLENOID ( WHEN REQUIRED ) BL-BK STOP ** 3 PHASE POWER IN BR BR J P Y 2 3 BL-BK 575V. CONNECTION OVERLOAD (UP TO 3/4 HP) GY 1 SAFETY EDGE NOTES: 1) TO REVERSE MOTOR DIRECTION: INTERCHANGE ANY 2 OF THE 3 POWER WIRES AT L1, L2 & L3, OR EXCHANGE PURPLE & GRAY MOTOR LEADS AT CONTACTOR 1 & 3 (3PH UNITS ONLY). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN GH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN GH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.