User manual CHAMBERLAIN CB11 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN CB11. We hope that this CHAMBERLAIN CB11 user guide will be useful to you.


CHAMBERLAIN CB11 INSTALLATION: Download the complete user guide (9402 Ko)

Manual abstract: user guide CHAMBERLAIN CB11INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] SAVE THESE INSTRUCTIONS This safety alert symbol means "Caution" - failure to comply with such an instruction involves risk of personal injury or damage to property. This gate drive mechanism is designed and tested to offer appropriately safe service provided it is installed and operated in strict accordance with the following safety rules. Incorrect installation and/or failure to comply with the following instructions may result in serious personal injury or property damage. When using tools and small parts to install or carry out repair work on a gate exercise caution and do not wear rings, watches or loose clothing. [. . . ] PT3 (TRIMMING POTENTIOMETER 3): FORCE SETTING (FORCE 1 MASTER) Definition of the force with which motor 1 = master is to operate. PT4 (TRIMMING POTENTIOMETER 4): FORCE SETTING (FORCE 2 SECOND) Definition of the force with which motor 2 = second is to operate. Impulse opens, the next one stops, the next one closes, the next one stops, the next one opens etc. Impulse during closing stops the gate Impulse during opening stops the gate Impulse during the rest closes the gate immediately Impulse opens pedestrian door, the next one stops, the next one closes, the next one stops, the next one opens etc. Impulse during closing stops the gate Impulse during opening stops the gate Impulse during the rest closes the gate immediately Gate open: Permanent signal required for closing, letting go stops Impulse opens, the next one stops, the next one closes, the next one stops, the next one opens etc. Impulse during closing stops the gate Impulse during opening stops the gate Impulse during the rest closes the gate immediately Gate closed: 1. Impulse opens, the next one stops, the next one closes, the next one opens Gate opened: 1. Impulse closes, the next one opens Impulse while pedestrian stops, the next one closes Impulse opens pedestrian door, the next one stops, the next one closes Impulse opens, the next one closes, the next one opens, the next one closes etc. Impulse while pedestrian closes the gate immediately Impulse during automatic closing opens the gate immediately Impulse during the rest closes the gate immediately. Impulse opens pedestrian door, the next one closes immediately Impulse during the rest closes the gate immediately Impulse opens, the next one stops, the next one opens, the next one stops etc. Impulse during closing stops the gate Impulse closes, the next one stops, the next one closes etc Impulse during opening stops the gate Gate closed: 1. Impulse opens pedestrian door completely, further impulses are ignored Impulse opens both wings completely, further impulses are ignored. Impulse while pedestrian opens the second wing as well Impulse during closing opens the gate immediately Impulse during closing opens the gate immediately Gate open: Permanent signal required, letting go stops Radio disabled, safety equipment disabled 709438 Gate closed: Permanent signal required, letting go stops Radio disabled, safety equipment disabled PHOTOCELLS (OPTIONAL) The photocells are for safeguarding the gate and must be used. EN12453 specifies that a pair of photocells must be installed at a height of 200 mm and activated to "Close"; a second pair must be installed at a height of 200 mm and activated to "Open". A third pair of photocells can be optionally installed and activated to "Close" and "Open". The photocells consist of a transmitter and a receiver and must be opposite each other. The housing of the photocell (plastic) can be opened using a screwdriver. The photocell is mounted on the wall using small screws and wall plugs. The Chamberlain failsafe system (2-cable system) has small LEDs (light) that can be seen from the outside on both sides to indicate the status of the photocell. The other model is ideal for the inside of the gate, because fittings are already available. Diagnosis at the Chamberlain failsafe photocell LED constant = OK LED flashes = photocell disables control board LED off = no current, incorrect connection or polarity Diagnosis on the control board LED off = OK LED on constantly = control board disables LED flashes = OK no photocell connected Cable cross-section: 0. Do not lay any 230 volt cables in parallel and do not lay any 2 cables in the same cable trunking. [. . . ] Each user should be instructed for at least 30 minutes with regard to the operation of the gate opener, whereby its functionality should be demonstrated and safety aspects, protective facilities and procedure in case of power failure should all be explained. All Chamberlain gate openers are equipped with a release system by means of which the gate can be operated manually in case of power failure. This process can be operated via remote control (a 2-channel remote control is the minimum requirement here) or via switch operation (see "Standard" operation mode setting). Gate opener does not function / does not respond when button is pressed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN CB11




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN CB11 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.