User manual CHAMBERLAIN APT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN APT. We hope that this CHAMBERLAIN APT user guide will be useful to you.


CHAMBERLAIN APT : Download the complete user guide (4861 Ko)

You may also download the following manuals related to this product:

   CHAMBERLAIN APT ADDENDUM (593 ko)
   CHAMBERLAIN APT REPLACEMENT PARTS (1700 ko)

Manual abstract: user guide CHAMBERLAIN APT

Detailed instructions for use are in the User's Guide.

[. . . ] Logic 3 OWNER'S MANUAL APT INDUSTRIAL DUT Y COMMERCIAL DOOR OPERATOR This Operator Features the Enhanced IN T ENA N C E M A E R T SYS T The Maintenance Alert SystemTM allows the installer to set an internal Maintenance Cycle Counter. The Logic 3 operator incorporates a self-diagnostic feature built into the (MAS) Maintenance Alert System LED. An LED on the 3-button station will signal when the set number of cycles/months is reached or when the operator requires immediate service. Radio Receiver Built on Board 2 YEAR WARRANTY 315MHz Serial # Box Installation Date NOT FOR RESIDENTIAL USE E PAT E N T P E N D I N G M A L TABLE OF CONTENTS SPECIFICATIONS Carton Inventory . . 8 AUTOMATICALLY LEARNED PROGRAMMING Auxiliary Reversal System/RPM Sensor . [. . . ] Compatible with 3-Button Station, 1-Button Station, 1 & 3 Button Remote Control. 17 PROGRAMMING Built in 3-channel, 315MHz radio receiver allows you to add as many as 23 Security® remotes or dip switch remote controls. PROGRAMMING REMOTES STANDARD SINGLE BUTTON REMOTE 1. To enter programming press and release the RADIO button on the logic board (LED will light). Press and hold the remote button until the LED flashes rapidly, then release remote button. The programming mode is exited if no activity is performed within 30 seconds. NOTE: Single button remote is not supported with D1 and E2 failsafe wiring modes. NOTE: Requires self-monitoring photo eyes when using constant pressure to close (wiring C2, D1 and E2 ). SINGLE BUTTON CONTROL (SBC) REMOTE This function programs a remote as a wireless single button control. In C2 mode, operation is OPEN / STOP/ Constant pressure to CLOSE / STOP on release. In T and TS modes, operation is OPEN / STOP / CLOSE / REVERSE / STOP and Timer to Close start/refresh. In FSTS mode, operation is OPEN with Timer to Close start/refresh only bypassing all up mid stops. Momentary and constant pressure commands are processed in this function. OPERATION MODE B2 C2 D1 E2 T, TS FSTS OPEN STOP CLOSE Reverse Constant Pressure Timer To Close WARNING To prevent possible SERIOUS INJURY or DEATH, install reversing sensors when the 3-button control station is out of sight of the door or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. CAUTION NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Ø14LGØ65 P4 E1 R29 C11 D3Ø2 X1 U1 K3 RADIO D16 P7 OLS D25 MID D24 1. Press and release the RADIO button on the logic board (LED will light). Press and release the SBC externally wired button or TIMER on the logic board (LED flashes rapidly and then remains on solid). Press and release the RADIO button on the logic board (LED flashes rapidly and then turns off). The programming mode is exited if no activity is performed within 30 seconds. ERASING REMOTES Press and hold the RADIO button on the logic board until the RADIO LED flashes rapidly (approximately 5 seconds). All remotes will be erased. SLS D26 CLS MRT MID D27 TIM RADIO 1 D36 2 RELAY C77 D35 C73 RELAY E2 D1 L1 LiftM ast er C2 C71 L5 B2 FAILSAFE P6 18 MOTOR REV C54 C78 ® PROGRAMMING Your 315MHz Security® or dip switch remote control can be programmed to operate as a 3-button wireless control station: the large button will open the door, the middle button will close the door, and the third button will stop the door's movement. To enter programming press the RADIO button on the logic board (the RADIO LED will light). To program the OPEN button to a remote control press the OPEN button on the logic board. The RADIO LED on the logic board will flash, this confirms that the remote control has been programmed. [. . . ] There may be more than one error present, but only the highest priority will flash. All errors self-correct when the corrective action is taken and a reset is not needed. 27 TROUBLESHOOTING RADIO FUNCTIONALITY The error codes will display at the radio LED. NOTE: Radio receiver is compatible with 315MHz remotes ERROR CODE R1 SYMPTOM No response from the remote DISPLAY Quick Flash POSSIBLE PROBLEM Unlearned remote A user tries to use a remote, but the RADIO LED only flashes briefly and there is no response from the operator. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN APT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN APT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.