User manual CARRIER GT-PX(50YD)

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CARRIER GT-PX(50YD). We hope that this CARRIER GT-PX(50YD) user guide will be useful to you.


CARRIER GT-PX(50YD) : Download the complete user guide (4088 Ko)

Manual abstract: user guide CARRIER GT-PX(50YD)

Detailed instructions for use are in the User's Guide.

[. . . ] The dual level compressor isolation mounting system, insulated compressor enclosure, and compressor discharge muffler make the 50YEW series one of the quietest water-to-water heat pumps available. The attractive "Euro-style" cabinet allows the unit to fit into any decor. · High temperature scroll compressor, up to 145°F [63°C] leaving water temperature. · Ultra high efficiencies (4. 2 COP at ground loop conditions; up to 5. 5 COP at ground water conditions). [. . . ] Bold outline indicates typical radiant floor application temperatures. Operation below 40°F EWT (source) is based upon 15% methanol antifreeze solution. All performance data is based upon the lower voltage of dual voltage units. Antifreeze for source water is required for operation in the shaded area and all source EWTs below 40°F. 50YEW 202 Carrier : Turn to the Exper ts. Carrier Geothermal Heat Pump Systems Physical Data Model Compressor (qty) Factory Charge HFC-410A (oz) [kg] 010 1 88 [2. 50] Indoor/Load Water Connection Size FPT (in) 1 Outdoor/Source Water Connection Size FPT (in) 1 Domestic Hot Water Connection Size FPT (in) 3/4 Maximum Working Pressure (Water Side) Base Unit (PSIG) [kPa] DHW Option (PSIG) [kPa] Internal Source Pump* w/Expansion Tank (PSIG) [kPa] Internal Load Pump * w/Expansion Tank (PSIG) [kPa] Weight - Operating, (lbs) [kg] Weight - Packaged, (lbs) [kg] Dual isolation compressor mounting Balanced Port Expansion Valve (TXV) Insulated Source and Load Water Coils 500 [3445] 145 [999] 45 [310] 45 [310] 455 [207] 470 [214] *Does not apply to DHW potable water circuit Residential Products Technical Guide 50YEW 203 GT-PW Water-to-Water (50YEW) Series 50YEW Dimensions 1. 9" [4. 9cm] 2. 1" [5. 3cm] Overall Cabinet Model A Depth in. 26. 8 68. 1 B Width 25. 6 65. 1 C Height 48. 9 124. 2 Water Connections 1 2 3 F Load (Indoor) Water In 22. 3 56. 6 4 G DHW Water Out 11. 3 28. 7 5 H Load (Indoor) Water Out 17. 7 45 6 J DHW Water In 14. 4 36. 6 Electric Access Plugs D E Source Source (Outdoor) (Outdoor) Water In Water Out 3. 4 8. 6 8. 1 20. 6 K Low Voltage 33. 6 85. 3 L Low Voltage 35. 6 90. 4 M Power Supply 38 96. 5 010 50YEW 204 Carrier : Turn to the Exper ts. Carrier Geothermal Heat Pump Systems Electrical Data Units with DHW Option Model Voltage Code G Voltage Min/Max Voltage 197/254 Compressor Qty 1 RLA 20. 7 LRA 81 *Load *Source Pump FLA 1. 07 1. 07 Pump FLA 1. 07 ISBP Pump FLA 1. 07 1. 07 Total Unit FLA 22. 8 23. 9 Min Circuit Amps 28 29. 1 Max Fuse HACR 45 45 50YEW010 THW010 208-230/60/1 Standard (No DHW) Model Voltage Code G Voltage Min/Max Voltage 197/254 Compressor Qty 1 RLA 20. 7 LRA 81 *Load *Source Pump FLA 1. 07 1. 07 Pump FLA 1. 07 Total Unit FLA 21. 8 22. 8 Min Circuit Amps 26. 9 28 Max Fuse HACR 45 45 50YEW010 THW010 208-230/60/1 *Denotes optional items. Consult unit data plate if configuration is unknown. Electrical - Wiring Diagram Matrix Model 50YEW010 50YEW010 50YEW010 50YEW010 Diagram Number 96B0108N05 96B0108N06 96B0108N08 96B0108N09 Voltage 230/60/1 230/60/1 230/60/1 230/60/1 Option VSFP DHW DHW + VSFP Residential Products Technical Guide 50YEW 205 Electrical Wiring Diagrams GT-PW Water-to-Water (50YEW) Series 50YEW010 Electrical Wiring Diagram - 230/60/1 96B0108N05 50YEW 206 Carrier : Turn to the Exper ts. Carrier Geothermal Heat Pump Systems 50YEW010 Electrical Wiring Diagram - 230/60/1 96B0108N05 Residential Products Technical Guide 50YEW 207 GT-PW Water-to-Water (50YEW) Series 50YEW010 Electrical Wiring Diagram - 230/60/1 VSFP - 96B0108N06 50YEW 208 Carrier : Turn to the Exper ts. Carrier Geothermal Heat Pump Systems 50YEW010 Electrical Wiring Diagram - 230/60/1 VSFP - 96B0108N06 Residential Products Technical Guide 50YEW 209 GT-PW Water-to-Water (50YEW) Series 50YEW010 Electrical Wiring Diagram - 230/60/1 DHW - 96B0108N08 50YEW 210 Carrier : Turn to the Exper ts. Carrier Geothermal Heat Pump Systems 50YEW010 Electrical Wiring Diagram - 230/60/1 DHW - 96B0108N08 Residential Products Technical Guide 50YEW 211 GT-PW Water-to-Water (50YEW) Series 50YEW010 Electrical Wiring Diagram - 230/60/1 DHW + VSFP - 96B0108N09 50YEW 212 Carrier : Turn to the Exper ts. Carrier Geothermal Heat Pump Systems 50YEW010 Electrical Wiring Diagram - 230/60/1 DHW + VSFP - 96B0108N09 Residential Products Technical Guide 50YEW 213 GT-PW Water-to-Water (50YEW) Series Engineering Guide Specifications General The water-source heating units shall be high temperature water-towater heat pumps. Units shall be performance rated in accordance with EN 14511-2 or ARI/ISO/ASHRAE 13256-2, and listed by a recognized safety-testing laboratory or agency, such as ETL. The quality control system shall automatically perform via computer: triple leak check, pressure tests, evacuate and accurately charge system, perform detailed heating mode tests, and quality cross check all operational and test conditions to pass/fail data base. Each unit shall be pallet mounted and shipped with appropriate protective packaging to help avoid damage in transportation. The units shall be warranted by the manufacturer against defects in materials and workmanship for a period of 10 years on all parts, and 10 years on the compressor and refrigerant circuit parts with a service labor allowance for 5 years on refrigeration components and 2 years on other parts. An optional extended warranty is available for the 50YEW Series units, which increases the labor allowance to 10 years on all parts. The water source units shall be designed to operate with entering Source temperature between 20 and 110°F [-7 and 43°C], and entering Load temperature between 50 and 130°F [10 and 54°C] with a maximum leaving load temperature of 145°F [63°C]. Casing & Cabinet The cabinet shall be fabricated from heavy-gauge galvanized steel and painted with a polyester powder coating. The interior shall be insulated with 1/2" [13mm] thick, multi-density, foil-backed coated glass fiber. Three access panels shall be provided and shall be removable with piping in place. The internal component layout shall provide for major service with the unit in place for restricted access installations. The units shall have an insulated compressor section to minimize the transmission of compressor noise. Refrigerant Circuit All units shall contain Puron® (HFC-410A) sealed refrigerant circuit employing a hermetic motor-compressor, thermal expansion valve, coaxial tube water-to-refrigerant Source heat exchanger, brazed plate Load heat exchanger, compressor discharge muffler, 100% molecular sieve filter drier with XH-11 desiccant, and service ports. Compressors shall be scroll type designed for heat pump duty and shall be double isolated from the cabinet with two sets of compressor mounting hardware. Compressor motors shall be single-phase PSC with internal over load protection. The coaxial water-to-refrigerant heat exchangers shall be designed for close approach temperatures and be constructed of a convoluted copper (optional cupro-nickel) inner tube and steel outer tube. The brazed plate heat exchanger shall be designed for close approach temperatures and shall be constructed with stainless steel plates. [. . . ] The Flow Controller shall provide 1" pump isolation valves/3-way service valves. The Flow Controller shall be enclosed in a polystyrene case and fully insulated with urethane foam to prevent condensation. Hose Connection Kit (field installed) An accessory hose kit shall provide 150psi [1034 kPa] 1" rubber hose with brass fittings equipped with service pressure/ temperature ports for connection between the unit and Flow Controller. Warranty Information The 2010 standard warranty applies to units ordered on or after July 1, 2010. See Carrier's 2010 Limited Express Residential Warranty Certificate CA234 for specific coverage and limitation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARRIER GT-PX(50YD)




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CARRIER GT-PX(50YD) will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.