User manual CARRIER 30EQIOM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CARRIER 30EQIOM. We hope that this CARRIER 30EQIOM user guide will be useful to you.


CARRIER 30EQIOM : Download the complete user guide (10655 Ko)

Manual abstract: user guide CARRIER 30EQIOM

Detailed instructions for use are in the User's Guide.

[. . . ] WARNING 3 signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. INTRODUCTION Carrier's PTAC Comfortt Series non-programmable thermostat is a wall-mounted, low-voltage thermostat which maintains room temperature by controlling the operation of a heating and/or air conditioning system. A variety of features are provided including battery operation, memory in case of power interruption, separate heating and cooling setpoints, backlighting, and built- installer test. [. . . ] Selections: F = Fahrenheit C = Centigrade Default is Fahrenheit Option 04 - Not used on a PTAC system Default = OF Option 07 - Not used on a PTAC system Default = OF Option 10 - Reversing valve (HP only) This selection is only available on heat pump systems. "O/B" terminal can be configured to be energized in either heating mode or in cooling mode, depending on heat pump operation. C -- Thermostat output (O/B) will have 24VAC in cooling mode, 0VAC in heating mode. H -- Thermostat output (O/B) will have 0VAC in cooling mode, 24VAC in heating mode. 13 Option 11 - Minimum Deadband Between Heating And Cooling Selections: 01 through 06 -- Default is 02. Sets the minimum allowable number of degrees between heating and cooling setpoints. One setpoint will "push" the other to maintain this difference. Option 13 - Room Air Temperature Offset Selections: - to 5_ F -- Default is 0. -5 This option selects the number of degrees F to be added to the displayed temperature to calibrate or deliberately miscalibrate the measured room temperature. Option 16 - Maximum Cycles Per Hour Selections: 2, 4, or 6 -- Default is 4. The maximum cycle rate is limited by internal timers to the selected number of cycles per hour. You can use these or change them so your room is as warm or as cool as you would like it to be. To change the heating temperature, press the mode button on the left until the screen says heat. Press the up or down button located on the right side of the display until you reach the desired temperature. To change the cooling temperature, press the mode button on the left until the screen says cool. Press the up or down button located on the right side of the display until you reach the desired temperature. Using the fan When the fan is on, it helps distribute air for a more even temperature in all spaces. You can set the thermostat so the fan runs continuously (on) or only 20 during your heating and cooling cycles (auto mode, sometimes known as cycle mode). The thermostat is set at the factory to run automatically as needed (auto). Using emergency heat (heat pump units only) Emergency heat is useful when the automatic auxiliary heat system can't keep up with demand. (Units with heat pumps use "auxiliary heat" when it's too cold outside for the heat pump to heat the space. The display indicator for this is aux heat on. ) Here's how to set your thermostat to use emergency heat. [. . . ] (See telephone yellow pages. ) THIRD: Contact: Carrier Corporation PTAC Consumer Relations P. O. Date of Installation Installed by Name of Owner Address of Installation 25 LIMITED WARRANTY for THERMOSTAT Carrier Corporation (hereinafter "Company") warrants this product against failure due to defect in material and workmanship under normal use and maintenance as follows. If a part fails due to defect within five (5) years from the date of purchase, Company will provide only a new or remanufactured part, at Company's sole option, to replace any defective part without charge for the part. This limited warranty is subject to the provisions, conditions, limitations, and exclusions listed below and on the reverse (if any) of this document. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARRIER 30EQIOM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CARRIER 30EQIOM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.