User manual CARLO GAVAZZI WM30-96 PROGRAMMING

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CARLO GAVAZZI WM30-96. We hope that this CARLO GAVAZZI WM30-96 user guide will be useful to you.


CARLO GAVAZZI WM30-96 PROGRAMMING: Download the complete user guide (1059 Ko)

Manual abstract: user guide CARLO GAVAZZI WM30-96PROGRAMMING

Detailed instructions for use are in the User's Guide.

[. . . ] 6 Visualization of the harmonics (see the table with the measurement screens below). 7 1 8 9 2 10 The keyboard in the bottom area is especially dedicated to instrument programming. 8 "Up" button, enables to browse the menus and to increase the values to be set. ADDITIONAL FUNCTIONS OF THE BUTTONS The buttons featuring a double icon have two functions, to access the secondary function, hold pressed for a long time the button corresponding to the desired secondary function. 9 "Down" button, enables to browse the menus and to decrease the values to be set. [. . . ] 70 PT RATIO: this function allows you to select the value of the VT-PT ratio (primary/secondary ratio of the voltage transformer being used). Example: Page 9 if the primary of the connected VT (voltage transformer) is 20kV and the secondary is 100V, then the VT-PT ratio corresponds to 200 (obtained carrying out the following calculation: 20000/100). 80 DMD: This function allows the user to select the calculation method of the DMD/AVG value of the selected variable. 81 TYPE: select the type of calculation mode to be used for the DMD/AVG calculation FIXED: if, for example, a time interval of 15 minutes has been selected, the instrument will calculate the AVD/DMD value of the measured variable and updates its value every 15 minutes. SLIDE: if for example a time interval of 15 minutes has been selected, the instrument calculates the AVG/DMD value and updates its value at the beginning after the first 15 values and then after every minute, thus generating a window whose width is of 15 minutes and that moves forward every minute. 82 TIME: select the time interval for the DMD/AVG calculation 83 SYNC: select the synchronization mode, that is the method that controls the calculation method of the average/demand according to the selected time. 90 SET POWER: This menu allows you to set a power value (installed power) that, in the measuring phase, will represent 100% of the graph indicator. 100 HOME PAGE: This function allows the user to select the variables to be displayed on first page (home page). 110 FILTER: Thanks to the digital filter, it's possible to stabilize the measurements which are too instable when displaying the relevant values. 112 FILTER CO: set the filtering coefficient of the instantaneous measures. By increasing the value, also the stability and the settling time of the measures are increased. Some specific menus display only if the relevant modules are installed * Self-recognize. Automation CARLO GAVAZZI Components PROGRAMMING WM30-96 How to costumize the home page of WM30-96 Menu "101 TYPE": A, you can select the variable for each row. Moreover, the selectable variables depend on the selected electric system, if 1P (one phase) system is selected, the available variables are different. 201 VARIABLES: select the variable to be retransmitted by means of the analog output. 202 MIN OUT: set the value expressed as % of the output range (0-20mA, 0-10V) to be coupled to the minimum measured value. 203 MAX OUT: select the value expressed as % of the output range (0-20mA, 0-10V) to be coupled to the maximum measured value. 204 MIN INPUT: minimum value of the variable input range to which the "MIN OUT" value, retransmitted by the analog output, will be coupled. 205 MAX INPUT: maximum value of the variable input range to which the "MAX OUT" value, retransmitted by the analog output, will be coupled. 220 METERS: reset the ENERGY METERS choosing among: TOTAL, PARTIAL: resets all energy meters, both total and partial. 240 CLOCK, 241 FORMAT: UE, set the time format as 24h european (00:00) or USA as 12h american (12:00 AM). [. . . ] MIN INPUT: 0, 0k; the multiple k, M, G can be selected on the instrument according to the chosen VT and CT values. MAX INPUT: 100. 0k; the k, M, G multiples can be selected on the instrument according to the selected VT and CT values. Retransmission of the POWER FACTOR (PF) by means of the 0-20mA analog output. It's necessary to retransmit the whole range of the admitted values for the PF with a signal from 0 to 20mA. Particular attention must be paid to the value of the PF variable which may vary from C0, 001 and L0, 000 (for each phase): these values will be retransmitted and will then correspond to 0 and 20 mA. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARLO GAVAZZI WM30-96




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CARLO GAVAZZI WM30-96 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.