User manual CARLO GAVAZZI WM3-96 PROGRAMMING

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CARLO GAVAZZI WM3-96. We hope that this CARLO GAVAZZI WM3-96 user guide will be useful to you.


CARLO GAVAZZI WM3-96 PROGRAMMING: Download the complete user guide (628 Ko)

Manual abstract: user guide CARLO GAVAZZI WM3-96PROGRAMMING

Detailed instructions for use are in the User's Guide.

[. . . ] 12 32bit µ-Processor based power quality analyser with modular housing for Plug and Play modules Instruction manual: INDEX TO BEGIN WITH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 s Front panel description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 s Display adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 s Page "00", starting page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 8- Press to exit the programming of the parameters of the relevant row (no boxes are to be highlighted); 9- press and to select one of the other programming lines; the pointer on the right shows the line where the user can modify the parameters (points from 1 to 7). Reset of the energy meters v 21 22 28 28 v 24 Energy Meters Management a) the day can be divided into up to 8 different periods connected to up to 4 different tariffs according to the following working principle: 20 18 16 22 24 2 4 6 8 trf1 14 12 10 + kWh - kWh + kvarh - kvarh 1 Imported active energy Exported active energy Imported reactive energy Exported reactive energy The measured energy (partial energy) is placed in TARIFF 1 when the time period is from midnight to e. g. The total measured energy is the result of the sum of all the partial measures as shown in the figure below: + kWh - kWh + kvarh - kvarh + kWh - kWh + kvarh - kvarh 1 trf1 20 18 16 22 24 2 4 6 8 trf1 14 + kWh - kWh + kvarh - kvarh T 12 10 trf2 2 b) the starting point of the first time period is always 24:00 (midnight) and cannot be changed; c) the starting point of the following period is always the end hour of the previous time period; d) the daily loop is closed by setting 24:00 as last hour of the last time period (to follow this procedure see point 4 on the previous page), confirm the setting by pressing and to go back to the TARIFF SELECTION menu. v 19 Average power calculation Trf holiday period 22 28 26 v Energy Meters Management 25 PROGRAMMING THE HOLIDAY PERIOD To program the HOLIDAY period, proceed in the following way. 10- Choose HOLIDAY in the SEASON menu by means of the and keys and confirm with : the HOLIDAY menu will be displayed (see figure on the left); 11-press : the month corresponding to the start date will be highlighted; 12-press : the box for setting the month will be enabled; and to select the 13-use desired month (from 1 to 12); 14-press the key to confirm the selection and move to the next parameter: day setting; 15-press the key again to open the box where the day is to be set; 16-use the and keys to select the desired day (from 1 to 31 depending on the previously selected month); 17-press the key to confirm the selection and move to the next parameter. 1. 2. . . . 2. 1 On page 26 To reset, press . v 23 Dual tariff management Display of harmonics 21 28 29 v 26 Energy Meters Management To program the "end date" follow the same procedure described above from No. After confirming the "end" day by means of the key, the HOLIDAY box is highlighted to indicate the conclusion of the HOLIDAY period programming cycle. You can also use the (moves from right to left) and (moves from left to right) keys to scroll along the available parameters. It's possible to choose the tariff to be associated to the HOLIDAY period according to the following procedure: From page 25 starting from the box on the previous page, number 10, press the key again: the instrument will display the box shown on the left. Press : the box of the "trf" value is highlighted; key again: the instrupress the ment will display on the lower section the box where the tariff is to be set. Select the desired tariff (from 1 to 4) by means of the and keys and confirm it with . . . 2. 1 Diagrams Meters reset v 21 22 28 28 v Energy Meters Management MULTI TARIFF 27 This function allows the management of the meters according to many periods per day and three periods per year: WINTER, SUMMER and HOLIDAY. To program the parameters relating to the winter season, simply follow the same procedure (holidays) described on page 25 from No. The parameters of the SUMMER season are automatically set by the instrument as a difference between the previous two periods of the Year. To enable the setting of the daily time periods, press when the WINTER or SUMMER seasons are highlighted. To reset your choices and/or go back to the previous menus, use the key. To program the HOLIDAY period, follow the procedure on page 25 from No. 17. The periods WINTER and SUMMER are conventional seasons mainly used to manage in the best way the different energy costs during the year. The reminds from letter a) to d) are also valid for the MULTI TARIFF function. The next page shows a few examples of programming the various time periods. Holiday period Pulse output v 25 22 28 31 v 28 Energy Meters Management trf1 20 18 16 14 12 10 8 22 24 2 4 6 DUAL TARIFF management trf1 WHOLE YEAR trf start end 1 OO:OO O8:OO 2 O8:OO 2O:OO 1 2O:OO OO:OO 1 TARIFF trf2 As you can see on the figure above, there is a daily division into three periods with two different tariffs. MULTI TARIFF management trf1 trf4 trf3 20 18 16 8 14 12 10 22 24 2 trf1 4 6 WINTER trf start end OO:OO O6:OO 1 2 O6:OO O8:OO 3 O8:OO 1O:OO 1 TARIFF trf2 trf2 trf3 WINTER trf start end 1O:OO 16:OO 2 3 16:OO 18:OO 4 18:OO 21:OO 1 21:OO OO:OO 2 TARIFF On the picture above you can see four different tariffs which are coupled to seven different periods of the day. Reset of the Energy meter The "RESET" menu allows you to reset the energy meters. Press to enter the menu, then use and to select the type of reset you prefer. Confirm the selection by means of the key: the instrument displays the following message: PAY ATTENTION, ALL THE METERS WILL BE RESET!!WILL YOU CONTINUE? v 23 Dual tariff Digital outputs 22 30 v Outputs / Other settings To conclude the RESET procedure, press the TARIFF SELECTION menu, press . 29 ; to go back to The reset procedure allows the user to choose among the following different choices: ALL: reset of all the energy meters (imported/ exported energies); TOTAL + : reset of the imported energy meters (+kWh, +kvarh); TOTAL - : reset of the exported energy meters (-kWh, -kvarh); PARTIAL + : reset of the partial imported energy meters (+kWh, +kvarh); PARTIAL - : reset of the partial exported energy meters (-kWh, -kvarh). s HARMONIC ANALYSIS This function enables the display of the windows relating to the harmonic analysis. Press to enter the menu; then, use the and keys to select the phase where you want to enable the harmonic analysis. [. . . ] RS422/RS485 SERIAL OUTPUT (on request): · Type: bidirectional multidrop (static and dynamic variables). · Protocol: MODBUS/JBUS Data (bidirectional): Dynamic (reading only) System variables: P, PAVG, S, Q, cos, VL-L, f, THD energies, status of digital inputs and status of the alarm output. Single phase variables: PL1, SL1, QL1, cosL1, VL1, AL1, THDL1, PL2, SL2, QL2, cosL2, VL2, AL2, THDL2, PL3, SL3, QL3, cosL3, VL3, AL3, THDL3 Static (writing only) All programming data, reset of energies, activation of the static output. v 57 Additional errors Energy Management 56 64 63 v 60 Technical features · Stored energy (EEPROM): max 999. 999. 999 kWh/kvarh · Data format: 1 start bit, 8 data bit, no parity/even parity/odd parity, 1 stop bit · Baud-rate: 1200, 2400, 4800 and 9600 baud, · Insulation: by means of optocouplers, 4000 Vrms between output and measuring inputs, 4000 Vrms between output and power supply inputs RS232 SERIAL OUTPUT (on request): · Type: bidirectional (static and dynamic variables). · Connections: 3 wires, maximum distance 15m · Data format: 1 start bit, 8 data bit, no parity, 1stop bit · Baud-rate: 9600 bauds · Protocol: MODBUS (JBUS) · Other data: as per RS485/RS422 DIGITAL OUTPUTS: (on request) The working of the outputs (pulse, alarm or both) is fully programmable and is independent of the output module that has been chosen. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARLO GAVAZZI WM3-96




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CARLO GAVAZZI WM3-96 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.