User manual CARLO GAVAZZI WM24-96 PROGRAMMING

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CARLO GAVAZZI WM24-96. We hope that this CARLO GAVAZZI WM24-96 user guide will be useful to you.


CARLO GAVAZZI WM24-96 PROGRAMMING: Download the complete user guide (604 Ko)

Manual abstract: user guide CARLO GAVAZZI WM24-96PROGRAMMING

Detailed instructions for use are in the User's Guide.

[. . . ] CARLO GAVAZZI Automation Components WM24-96 Universal Utility Meter Contatore Universale USER MANUAL MANUALE ISTRUZIONI Modular system Tecnologia modulare CARLO GAVAZZI Automation Components Plu TH A g N K FO R M and od Pla ule sy YO U CH Welcome in the Carlo Gavazzi world and compliments for your smart choice. Visit our website and evaluate our range of products: www. carlogavazzi. com OOS ING C A RL O GA V A Z Z I WM24-96: Modular Universal Utility Meter and Power Analyzer Plug and play module system; energy meters, gas and water meter. These are only a few among many other functions performed by your WM24-96. What's more, Carlo Gavazzi means ISO9001 certification, a working experience of many decades and a widespread presence all over the world. [. . . ] Select the number of pulses by means of v w (pulses/kWh from S v 1. 2. . The programming continues for digital output 2. Digital output 2 on page 19 Digital Input Table End of Programming v 15 9 22 21 v 18 S Programming Alarm Digital Output This function allows the user to set the parameters of the alarm digital output. Choose the "diGout1- ALr" function by means of the v w keys: to enter the S vw menu press S . Then, set the following parameters: VAr: choose the variable to be associated to the alarm activation by means of the v and w keys and confirm with S . on: activation set-point, value of the variable over which the alarm is activated. Select the value of the variable by means of the v and w keys and confirm it with S ; oFF: deactivation set-point, value of the variable over which the alarm is deactivated. Select the value of the variable by means of the v and w keys and confirm it with S ; nd: normally de-energized output when there is no alarm. . . 2. 1 w of the v and w keys and confirm it with S ; Energy Meters Menu Digital Filter v 13 9 22 20 v Programming 19 SEC: delay time from the detection of the alarm and the activation of the output. . . 2. 1 w the v and w keys (up to 255 seconds) and confirm with S . Digital output 2 Digital Output 2 S PUL: access to the retransmission functions of the totalized energy by means of pulses (see pulse digital output on page 16). To enter the relevant menu press S ; rEn: enables the activation of the output by means of the serial communication. Confirm with enable the function. S to S vw Retransmittable en. meters Useful Information v 17 9 22 23 v 20 S Programming s RS422/485 Serial port address Select "AddrESS" from the main menu by means of the v and w keys; to enter the menu press S , then set the desired serial address value (from 1 to 255) by means of the v and w keys and confirm it S v 1. 2. . . . 2. 1 w with S . s Digital Filter Select "FiLtEr" by means of the v S and w keys: to enter the menu press S . Select the parameters to be set with the v and w keys, to enter S v 1. 2. . There are two parameters: - rnG, sets the operating range of the digital filter. The value is expressed as % of the full scale value: set the desired value (from 0 to 100%) by means of the v and w keys and confirm it with S ; S v 1. 2. . . . 2. 1 w - Coe, sets the filtering coefficient of the instantaneous measurements. Set the desired value (from 1 to 16) by means of the v and w keys and confirm it with S . By increasing the value both the stability and the settling time of the measurements are increased. See also "Example 2" in Useful Information on page 23. Meters Increase Meters Reset v 15 9 22 22 v Programming 21 s End of programming To exit from programming and go back to the measuring mode, select "End" from the main menu by means of the w and v keys, confirm it with S . S Measuring Instrument mode revision s Reset of total meters Select "rESEt tot" from main menu by means of the v S S w keys, S . When the then confirm with instrument asks for the reset, choose, by means of the v w keys: "no" to avoid the reset or "yes" to confirm it. Then, press S to carry out the command. S vw RESET Digital Output 2 Up/Down Alarm v 19 9 22 25 v 22 Programming s Reset of partial meters Select "rESEt Prt" from the main menu by means of the v w keys, S then confirm with S . [. . . ] Addresses: from 1 to 255, selectable by key-pad Protocol: MODBUS/JBUS (RTU) Data (bidirectional) Dynamic (reading only) System and phase variables: see "display pages" on page 41 All configuration parameters, activation of the static output. Insulation: By means of optocouplers, 4000 VRMS between output and measuring input, 4000 VRMS between output and power supply input. RS232 (optional) Bidirectional (static and dynamic variables) Connections: 3 wires, max. Protocol: MODBUS (JBUS) Other features: as per RS422/485 Pulse outputs (optional) Number of outputs: Up to 2 Type: from 1 to 100 programmable pulses VON 1. 2 VDC/ max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARLO GAVAZZI WM24-96




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CARLO GAVAZZI WM24-96 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.