User manual CANNON HB40042G

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANNON HB40042G. We hope that this CANNON HB40042G user guide will be useful to you.


CANNON HB40042G : Download the complete user guide (1281 Ko)

Manual abstract: user guide CANNON HB40042G

Detailed instructions for use are in the User's Guide.

[. . . ] For full safety warning information, Refer to Heater User Instructions. CAUTION: The thermostat has already been programmed with a unique code. Do not attempt to teach the RF Thermostat ID code unless instructed by the manufacturer. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for safety. Children should be supervised to ensure that they do not play with the appliance. Features of your thermostat model heater: This heater features a safety interlock mode to prevent accidental or inappropriate activation of the hand held remote control unit. [. . . ] The temperature range is 7°C to 32°C. Day of week SU MO TU WE TH FR SA Temperature display Room set indicator ROOM SET When the thermostat is on, the programmed (set) temperature will be displayed. When the thermostat is off, only the room temperature will be displayed. Indicates that the thermostat is transmitting to the receiver, the symbol will appear on the LCD for 1 second. The thermostat will remain functional for approximately another 5 days before shutting down. Transmit indicator Battery low indicator Programming mode indicator Automatic / manual mode indication Flame indicator PROG Indicates that the thermostat is in programming mode. Indicates the flame height: HIGH FIRE MEDIUM FIRE* LOW FIRE *Medium Fire is not a function of this heater Indicates the fan speed. The fan ranges are graduated settings: 1, 2, 3. Page 6. MANUAL AUTO Fan indicator Functions Button Functions Button PWR Function On Description Switches the thermostat on. If the thermostat is off, pressing and releasing the PWR and OK button together will turn the thermostat on to the most recently selected working mode. Switches the unit off. PWR PWR OK PWR Off OK OK Enter Accepts the current function and advances the next function. Decrement hours, minutes, day or temperature. UP UP DOWN DOWN A/M A/M Automatic Toggles between automatic and manual / Manual mode. Programming button function T T Time Indicates time and day of the week programming (must press and hold for 2 or more seconds when thermostat is off). Indicates the programming mode (must press and hold for 2 or more seconds when thermostat is off). P P Program Page 7. Initial Setup ON If the `PWR ' is off, the heater will not start. Press and release the `PWR ' and `OK' buttons together, pressing and releasing `PWR ' and `OK' buttons will turn the thermostat on to the most recently selected working mode or the factory default setting if not previously programmed. At any time, the temperature or fan speed may be adjusted up or down similar to operating in manual mode. However, whenever the thermostat changes to a new time period, the temperature will be reset automatically according to that period's setting. Page 9. Programming Each day of the week can be programmed individually for periods P1, P2, P3, and P4, making a total of 28 programmed periods. Alternatively, a weekday program can be set, so the same program is used for Monday to Friday. Alternatively, a weekday or weekend program can be set with individual programs for the remaining days. The suggested period settings for each day/s are: Period 1 - morning Period 2 - daytime Period 3 - evening Period 4 - night time. With the thermostat off, press and hold the `P' button for 2 seconds or longer to initiate programming. The LCD will display PROG, Pd and the time at which the thermostat is currently set MO will flash. Press and release the `UP ' or `DOWN ' button to change the day of the week to the following or previous day. Press and hold the `UP ' or `DOWN ' button for 2 seconds or longer to increase or decrease the day of the week by 1 day every 0. 5 seconds. The order that you can scroll through the days is as follows: MO>TU>WE>TH>FR>MO TU WE TH FR>SA>SU>SU SA>MO TU WE TH FR SA SU To accept the selected day/s of the week press `OK '. Page 10. Setting the period starting time. To set the P1 starting time, press and release the `UP ' and `DOWN ' button to increase or decrease the hour setting. [. . . ] Press and hold for the hour to increase or decrease 1 hour every 0. 5 seconds. Press `OK ' and press and release the `UP ' or `DOWN ' buttons to change the day of the week. Program the thermostat With the thermostat off, press and hold the `P' button. To select Monday press `OK ', or press and release `UP ' or `DOWN ' to change the day of the week, or to switch to the weekday or weekend setting. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANNON HB40042G




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANNON HB40042G will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.