User manual CANNON HB1113296

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANNON HB1113296. We hope that this CANNON HB1113296 user guide will be useful to you.


CANNON HB1113296 : Download the complete user guide (3045 Ko)

Manual abstract: user guide CANNON HB1113296

Detailed instructions for use are in the User's Guide.

[. . . ] Any product subjected to misuse, abuse, negligence, accident or alteration will have its warranty voided. If installation is not carried out in accordance with manufacturer's instructions, this warranty may be void. The customer must keep their "Tax Invoice" as proof of purchase of this product and compliance certificate as proof of required installation. Model number: ______________________________________ Serial number: _______________________________________ Date of manufacture: _________________________________ Date installed: _______________________________________ Compliance Certificate No: ____________________________ Designed, manufactured and distributed by: Sampford and Staff Pty Ltd. [. . . ] Normally the heater should only need wiping with a lint - free damp cloth. Any stubborn stains can be removed with a non-abrasive spray on cleaner. Internally the heater should only be cleaned by a licensed service person listed in this manual. If your heater requires attention contact your supplier or licensed service person listed in this manual. Important: The appliance should be inspected before use and at least annually by an authorised service person. More frequent cleaning may be required due to excessive lint build-up from carpeting, bedding materials, pet hair, etc. It is imperative that control compartments, burners and circulating air passage ways of the appliance be kept clean. Do not use this fire if the glass is cracked or with the glass safety screen removed. 8 Heater Specifications Do not use fire with broken or missing logs. Gas type: Gas consumption: Energy star rating: Energy output: Heater type: Operating pressure: Gas regulator: Min. inlet pressure: Natural or Propane gas, as indicated on data label 26 MJ/hr input 3. 77 20. 7 MJ/hr Heater approved to AG 103. Natural gas: 1. 0 kPa Propane gas: 2. 65 kPa Integral with controller (NG) 1. 13 kPa (NG) Propane gas: Regulated to supply 2. 70 kPa to appliance Fan: Controller: Minimum cavity dimensions Power requirement: Optional Accessories: Three speed Electronic Height: 605mm dimensions* Width: 695mm Depth: 385mm 240 VAC 10 A · Safety guard · Gold trim · Mock fireplace installation kit* Refer fig. Close gate over gas supply and seal around the pipe with fibreglass insulation material. Sealing is important as it prevents leakage from fan chamber into chimney: also check for gas soundness. 19 Fuel bed and log installation 16. The fuel bed is retained by a spring clip fixed to the rear of the burner chamber FUEL BED MUST BE HARD UP AGAINST REAR OF BURNER. 20 17. Logs are numbered as follows: No 1 - Left front log No 2 - left back log No 3 - Right front log No 4 - Right back log Position the four individually numbered logs in the following order on the fuel bed as shown in figure 21-24. The male locating pins in fuel bed must engage with corresponding holes in the individual logs. a) Place log No. 1 onto the 2 front left pins on the fuel bed, see figure 21. 21 13 b) Place log No. 2 onto the 2 left back pins. Refer figure 22. 22 c) Place log No. 3 on single right front pin, ensure fork locates over log No. 4 on single right back pin, ensure left side of log rests on depression in No. The rearward sloping frame must be at the top and the vertical ledge must be at the bottom. Connect plug to the wall socket and switch it on. 14 Gas control 23. Gas control layout is as indicated in figure 26. Pressures for `Burner full on' and `Burner low flame' are factory set, however if pressures need to be checked or adjusted follow the procedures described below and on the next two pages. 26 To check control outlet pressure at burner `Full on" and `Low Flame" positions remove the plastic cap from the regulator adjustment location as indicated in figures 27 (a) & (b). 27 Gas pressure point 24 The pressure point is closed with a captive screw. [. . . ] To reset the module turn off the power supply for 10 seconds and then turn the power on again. · Check the internal 3. 5 amp fuse in the module. 3 After resetting the module and appliance is still not operating. and still appliance not operating 4 · Check other connections are in place. · If the last checks are correct the ignition electrode should spark at the same time as the gas control solenoid valves open. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANNON HB1113296




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANNON HB1113296 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.