User manual CANNON FITZROYIN-BUILT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANNON FITZROYIN-BUILT. We hope that this CANNON FITZROYIN-BUILT user guide will be useful to you.


CANNON FITZROYIN-BUILT : Download the complete user guide (1011 Ko)

Manual abstract: user guide CANNON FITZROYIN-BUILT

Detailed instructions for use are in the User's Guide.

[. . . ] Cannon FITZROY INBUILT INBUILT MODELS FITZIB-SDSEB-NG FITZIB-SDSEB-LP USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS This heater is approved for use with Natural and Propane gases. Please leave instructions with the owner Contents Contents Warranty Distributor Safety warnings What to do if you smell gas Warnings Standards User instructions Operating instructions Cleaning Flame characteristics Heater specifications Installation instructions Clearances Fitment of cabinet depth spacer Installation into a masonry/brick or mock fireplace Installation WITH a flue connected Installation WITHOUT a flue connected Sealing 15 16 17-18 9 10-14 6-8 4-5 2 3 Gas connections Log installation Gas control Gas pressure point Gas pressure adjustment Installation tips Trouble-shooting Connections Service instructions General To replace the primary glass To replace outer glass To replace the gas control To replace the ignition (module) device To replace the room circulation fan To replace the fan pressure switch To remove the heat exchanger To replace the burner and spark/sense electrode Wiring diagram Data plate For service to this appliance 19 20-21 22-24 2 Warranty The Cannon appliance is warranted against defects in materials and workmanship for a period of one, (1) year from its date of original purchase, for residential use in Australia. Warranty service, which includes parts and labour for the replacement or repair of defective parts, is available through the CANNON distributor. Consumers are responsible for service person's travel outside normal service areas (approximately seventy (70k) radius from the nearest Cannon dealer's location), local cartage, and normal maintenance as described in this manual. [. . . ] a) Place log No. 1 onto the 2 front left pins on the burner head, ensuring that the charring faces the front. Refer figure 29. 29 c) Place log No. 3 on single right front pin, ensure fork locates over log No. 4 on single right back pin, ensure left side of log rests on depression in No. Reconnect the switch loom to the electronics module. Advise the user in the operation of the heater. 21. Connect plug to the wall socket and switch it on. 16 Gas control Important: To achieve the correct visual flame effect: On Propane the gas pressure must be set at 2. 65 kPa with burner operating on maximum setting. On Natural Gas the gas pressure must be set at 0. 75 kPa with burner operating pressure on maximum setting. 23. Pressures for `Burner full on' and `Burner low flame' are factory set, however if pressures need to be checked or adjusted follow the procedures described below and on the next two pages. 32 To check control outlet pressure at burner `Full on" and `Low Flame" positions remove the plastic cap from the regulator adjustment location as indicated in figures 33 (a) & (b). 33 Gas pressure point 24. Turn screw 6 revolutions anticlockwise to open the pressure point as indicated on figure 34 (a) and place manometer tube over the test point as per figure 34 (b). 34 Gas pressure adjustment 25. Switch the top two control buttons to "Full On" position as indicated in figure 35(a) and using a ring spanner, as per figure 35(b), adjust the 17 pressure to 0. 75 kPa for Natural gas or 2. 65 kPa for LPG. (Turn clockwise to increase pressure and anticlockwise to decrease pressure). 35 26. Switch the heat button back to "Low Flame' position as indicated in figure 36(a), retain spanner in position and using a screwdriver as per figure 36(b) adjust the central screw control to give a pressure reading of 0. 3 kPa for Natural Gas and 1. 1 kPa for LPG. (Turn clockwise to increase pressure and anticlockwise to decrease pressure). 36 27. Tighten pressure test point by turning the captive screw fully clockwise. Ensure the little lug is positioned towards lower right hand side to clear the control. Refit the lower front cover, making sure not to damage the power cord. The flame should be stable, no lifting from the burner and the logs should glow after approximately 15 minutes of operation at HIGH burner. If the flame is unstable: Check that the burner is located correctly. Check that the glass front is located correctly and is against the sealing rope. If the heater still does not operate to specification refer to the troubleshooting chart on pages 20 & 21, or contact Sampford IXL in your state. 18 Installation tips Test the operation of the chimney before installing the new heater. CANNON heaters are high efficiency products with low flue gas temperatures (typically 100°C) so if you are replacing an older type radiant heater with a much higher flue gas temperature (150°C or higher) make sure of the integrity of the fireplace and chimney before installing the new CANNON log fire. A solid, levelled and smooth base is required (fill gaps with fibreglass insulation if necessary). Avoid installing into large volume fireplaces and chimneys and not fitting a flue. We recommend cleaning or sweeping of the chimney and fireplace before the installation of the heater commences. [. . . ] Disconnect the gas inlet (1/2" compression nut) connection at entry to gas control and the 16mm nut at the outlet of the gas control. Replace gas control and ignition device in reverse order and check for gas tightness. Refer `gas control', pages 17 and 18. To replace the ignition (module) device 1. Refer `to replace the gas control' and perform steps 1 to 3, but do not remove the earth connection from the gas control. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANNON FITZROYIN-BUILT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANNON FITZROYIN-BUILT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.