User manual CANNON FITZROYFREESTANDING

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANNON FITZROYFREESTANDING. We hope that this CANNON FITZROYFREESTANDING user guide will be useful to you.


CANNON FITZROYFREESTANDING : Download the complete user guide (560 Ko)

Manual abstract: user guide CANNON FITZROYFREESTANDING

Detailed instructions for use are in the User's Guide.

[. . . ] Cannon FITZROY FREESTANDING FREESTANDING MODELS FITZFS-SDSEB-NG FITZFS-SDSEB-LP USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS This heater is approved for use with Natural and Propane gases. Please leave instructions with the owner Contents Contents Distributor Warranty Safety warnings What to do if you smell gas Warnings Standards User instructions Operating instructions Flame characteristics Cleaning Heater specifications Installation instructions Clearances Installation Gas connection Log installation Gas control Gas pressure point Installation tips 16-17 9 10-15 6-8 3 4-5 2 Flue installation Flue kit Service instructions 18-20 General To replace primary glass To replace outer glass To replace the gas control To replace the ignition (module) device To replace the room circulation fan To replace the fan pressure switch To remove the heat exchanger To replace the burner and spark/sense electrodes Wiring diagram Data label For service to this appliance 21-22 Trouble shooting Connections 2 Warranty The Cannon appliance is warranted against defects in materials and workmanship for a period of one, (1) year from its date of original purchase, for residential use in Australia. Warranty service, which includes parts and labour for the replacement or repair of defective parts, is available through the CANNON distributor. Consumers are responsible for service person's travel outside normal service areas (approximately seventy (70k) radius from the nearest Cannon dealer's location), local cartage, and normal maintenance as described in this manual. [. . . ] Tighten pressure test point by turning the captive screw fully clockwise. Ensure the little lug is positioned towards lower right hand side to clear the control. Refit the lower front cover, making sure not to damage the power cord. 14 23. Follow User Instructions to turn on heater and test for correct operation before leaving. 24. The heater flames should be stable, not lifting from burner and the logs should glow after approximately 15 minutes operation on HIGH setting. The heater has been designed to burn with luminous flames, which mimic natural log combustion, and may exhibit slight carbon deposits. If heavy carbon deposits occurs or flames impinge on the roof of the combustion chamber, turn the appliance off and contact the service agent in your state. 25. If after following these installation instructions and the trouble shooting chart on page 20-21, the heater does not perform correctly contact the service agent in your state. For details of service agents please refer page 19. Installation tips Make sure that the heater is fully commissioned and be certain to conduct a test of the integrity of the flue operation, taking into account any influences created by range-hoods, exhaust fans, central heating, etc. To avoid any unnecessary delays and inconvinience to your customer, please contact our Technical Services Department on 1300 727 421, if the installation is unusual or you have any concerns with the installation and/or heater operation before the installation commences. Any service request resulting from incorrect installations are not covered by our warranty conditions and these calls will result in charges, usually to the end user, so please be sure that the installation and commissioning has been satisfactorily carried out before calling for a warranty service. Please make sure that the end user is fully instructed on how to operate the heater. 15 Flue installation This heater is a flued appliance. It must be properly connected to a flue system in accordance with the latest edition of the Gas Installation Code, AS 5601. If elbows are required, we recommend 45° only and no more than two in the total flue run. There should also be a minimum of 250mm straight flue section in between bends. If practical, locate the heater in a position to minimise the need for elbows. There must be at least 1. 8m of vertical before any changes in direction of the flue. If placed against a combustible wall the 40mm rear spacers locate against the wall. The centre line of the flue is 115mm to rear of appliance (including rear spacers). Carry out installation as per figure 26 (ceiling plate installation) and figure 27 (flue installation). Cut a hole 180mm ø in the ceiling in line with the flue position. Secure ceiling plate against the ceiling by bending out the tabs above the ceiling. [. . . ] At this point the spark electrode will activate for up to 10 seconds maxi mum until the flame has been established. Terminal 14 (white wire into the 8 way switch connector) will be energised as soon as the flame has been sensed. · A blue spark can be seen when the heater ignition process starts. · Check that there is no short circuit to earth and spark gap is correct. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANNON FITZROYFREESTANDING




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANNON FITZROYFREESTANDING will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.