User manual CANNON FITZROY IN-BUILT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANNON FITZROY IN-BUILT. We hope that this CANNON FITZROY IN-BUILT user guide will be useful to you.


CANNON FITZROY IN-BUILT : Download the complete user guide (326 Ko)

Manual abstract: user guide CANNON FITZROY IN-BUILT

Detailed instructions for use are in the User's Guide.

[. . . ] Consumers are responsible for service person's travel outside normal service areas (approximately seventy (70k) radius from the nearest Cannon dealer's location), local cartage, and normal maintenance as described in this manual. Any product subjected to misuse, abuse, negligence, accident or alteration will have its warranty voided. If installation is not carried out in accordance with manufacturer's instructions, this warranty may be void. The customer must keep their "Tax Invoice" as proof of purchase of this product and compliance certificate as proof of required installation. [. . . ] Models CANTIB-NG & CANTIB-LP can be installed onto a masonry/ brick fireplace or mock fireplace. If installing into a mock fireplace a mock fireplace installation kit MUST be used. The mock fireplace installation kit can be ordered from the CANNON distributor. For installation onto a masonry or brick fireplace WITH a flue connection refer figure 11. After installation of the heater/flue test the flue to confirm air vents are unobstructed. If an exhaust fan or other heating appliances are present switch them on. This is to test that there is no interaction between the CANNON heater and other appliances. 10 Refer AS5601. For "air movement not to affect appliance" see clause 5. 3. 1. For `ventilation requirements' see clause . 5. 4. 3. Installation WITH a flue connected 11 11 Installation WITHOUT a flue connection. 12 13 12 6. If using a power point in the chimney, route the plug and cord through cord access at lower LH side of rear panel. Hard (fixed ) wiring connection is to be carried out only by a qualified electrician. 14 7. We recommend cleaning or sweeping of the chimney and fireplace before the installation of a new heater. There must be a good seal around the heater, gas piping and electrical cable rear entry to stop any leakage of combustion products. Do not use adhesives or silicone sealant, the heater must be able to be easily removed if necessary. Install a chimney plate and cowl to the chimney opening using weatherproof mortar to common building practice. Remove any curved firewall that slopes too far forward to the fireplace opening if it causes restriction to the flue path above the heater flue outlet. Make sure that the heater is fully commissioned and be certain to conduct a test of the integrity of the flue operation, taking into account any influences created by rangehoods, exhaust fans, central heating, etc. To avoid any unnecessary delays and inconvenience to your customer, please contact our technical services department on 1300 727 421 if the installation is unusual or you have concerns with the installation and/or heater operation before installation. Any service requests resulting from incorrect installations are not covered by our warranty conditions and these calls will result in charges, usually to the end user, so please ensure that the installation and commissioning is satisfactorily carried out before calling for any warranty service. Please make sure that your customer is fully instructed on how to operate the heater. 19 Service instructions (Do not modify this appliance) General 1. Unplug from wall socket or turn off power at main switchboard if heater is hard wired. Always shut off the gas supply and ensure that the heater is cool before commencing any service operations. [. . . ] · Check the external 2-A fuse in the loom. 2. Power present but appliance not operating. 3. After resetting the module and appliance is still not operating. and still appliance not operating. 4. · Check other connections are in place. · If the last checks are correct the ignition electrode should spark at the same time as the gas control solenoid valves open. At this point the spark electrode will activate for up to 10 seconds maxi mum until the flame has been established. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANNON FITZROY IN-BUILT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANNON FITZROY IN-BUILT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.