User manual CANNON FITZROY PROFILE INBUILT FITZPIBPWR

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANNON FITZROY PROFILE INBUILT FITZPIBPWR. We hope that this CANNON FITZROY PROFILE INBUILT FITZPIBPWR user guide will be useful to you.


CANNON FITZROY PROFILE INBUILT FITZPIBPWR : Download the complete user guide (101 Ko)

Manual abstract: user guide CANNON FITZROY PROFILE INBUILT FITZPIBPWR

Detailed instructions for use are in the User's Guide.

[. . . ] Any product subjected to misuse, abuse, negligence, accident or alteration will have its warranty voided. If installation is not carried out in accordance with manufacturer's instructions, this warranty may be void. The customer must keep their "Tax Invoice" as proof of purchase of this product and compliance certificate as proof of required installation. Model number: ______________________________________ Serial number: _______________________________________ Date of manufacture: _________________________________ Date installed: _______________________________________ Compliance Certificate No: ____________________________ Don't risk your appliance warranty Only a licensed person will give you a Compliance Certificate, showing that the work complies with all the relevant standards. [. . . ] This is the requirement for installation into a masonry or brick fireplace without flue connection. Installation into a masonry/brick or mock fireplace. 5. Models FITZIB-SDSEB-NG & FITZIB-SDSEB-LP can be installed into a masonry/brick fireplace or a mock fireplace. If installing into a mock fireplace a mock fireplace installation kit MUST be used. Order specification for the part is `Mock kit". 10 For installation into a masonry or brick fireplace WITH a flue connection refer figure 12. After installation of the heater test the flue to confirm air vents are unobstructed. If an exhaust fan or other heating appliances are present switch them on. This is to test that there is no interaction between the Cannon heater and other appliances. For `ventilation requirements' see clause 5. 4. 3. Installation WITH a flue connected 12 11 Installation WITHOUT a flue connected 13 14 12 15 6. If using a power point in the chimney, route the plug and cord through cord access at lower LH side of rear panel. Hard (fixed) wiring connection is to be carried out only by a qualified electrician. Remove the lower front cover by unscrewing two M5 screws from the air intake slot. We recommend cleaning or sweeping of the chimney and fireplace before the installation of the heater commences. There must be a good seal around the heater, gas piping and electrical cable rear entry to stop any leakage of combustion products. Do not use adhesives or silicone sealant, the heater must be able to be easily removed if necessary. Install a chimney plate and cowl to the chimney opening using weatherproof mortar to common building practice. Remove any curved firewall that slopes too far forward to the fireplace opening as it causes restriction to the flue path above the heater flue outlet. Make sure that the heater is fully commissioned and be certain to conduct a test of the integrity of the flue operation, taking into account any influences created by rangehoods, exhaust fans, central heating, etc. To avoid any unnecessary delays and inconvenience to your customer, please contact our Technical Services Department on 1300 727 421 if the installation is unusual or you have concerns with the installation and/or heater operation before the installation commences. Any service requests resulting from incorrect installations are not covered by our warranty conditions and these calls will result in charges, usually to the end user, so please ensure that the installation and commissioning has been satisfactorily carried out before calling for any warranty service. Please make sure that your customer is fully instructed on how to operate the heater. 19 Trouble-shooting - (Do not modify this appliance) To check the operation of the electronic (module) controller (Type 537 ABC) you will require a digital multimeter with the functions to measure AC/DC voltage, continuity, resistance and micro-amps. It is critical that the appliance is earthed and that the active and neutrals are not reversed. Item No Check Action 1. No ignition when appliance is turned on. · Check 240 volts power to heater in incoming plug connector. If the fan has malfunctioned, or is faulty, the fan pressure switch will recognise this and not allow the heater to function. [. . . ] Remove the lower front cover by unscrewing two M5 screws through the air intake slot. The blue module (ignition device) needs to be removed to allow removal of the gas control. Remove screw from front of rectifier lead located below domed cap on gas control. Unplug polarise plug (wires feeding to module and gas control) and remove spark/sense electrode connections, earth connection from module and earth connection form gas control. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANNON FITZROY PROFILE INBUILT FITZPIBPWR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANNON FITZROY PROFILE INBUILT FITZPIBPWR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.