User manual CANDY CVG6BR4WPW

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANDY CVG6BR4WPW. We hope that this CANDY CVG6BR4WPW user guide will be useful to you.


CANDY CVG6BR4WPW : Download the complete user guide (6877 Ko)

You may also download the following manuals related to this product:

   CANDY CVG6BR4WPW (1329 ko)

Manual abstract: user guide CANDY CVG6BR4WPW

Detailed instructions for use are in the User's Guide.

[. . . ] It is strongly recommended to keep children away from the cooking zones while they are in operation or when they are switched off, so long as the residual heat indicator is on, in order to prevent the risks of serious burns. This appliance is not intended to be operated by means of an external timer or separate remote control system. Connect a plug to the supply cable that is able to bear the voltage, current and load indicated on the tag and having the earth contact. The socket must be suitable for the load indicated on the tag and must be having the earth contact connected and in operation. [. . . ] The appliance must only be connected to a suitably rated spur point, a 3 pin 13 amp plug/socket is not suitable. A double pole switch must be provided and the circuit must have appropriate fuse protection. Further details of the power requirement of the individual product will be found in the users' instruction and on the appliance rating plate. In the case of built-in product you are advised, should you wish to use a longer cable than the one supplied, that a suitably rated heat resistant type must be used. The wiring must be connected to the mains supply as follows: Note: We do not advocate the use of earth leakage devices with Electric cooking appliances installed to spur points because of the You are again reminded that the Appliance must be correctly earthed, the manufacturer declines any Check the data on the rating plate, located on the outside of the unit, to ensure that the supply and input voltage are suitable. If this regulation is not complied with, the Manufacturer will not be responsible for any damage caused to persons or property. If a plug is not already attached, fit a plug appropriate to the load indicated on the rating plate. Where the Hob is connected direct to the electricity supply, a circuit breaker must be fitted. If the power supply cord is damaged this is to be replaced by a qualified engineer so as to prevent any potential risk. The earth wire ( green and yellow coloured ) must be at least 10 mm longer than the live and neutral wires. The section of the cable used must be of the correct size in relation to the absorbed power of the hob. Please check rating plate for the power details and ensure that the power supply cord is of the type 3x0. If an appliance is not fitted with a supply cord and a plug, or with other means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III conditions, the instructions shall state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. These instructions are for qualified personnel, installation of equipment must be in line with the relevant national standard. Only: by law the gas installation\commissioning must be carried out by a "Gas Safe" installer) All work must be carried out with the electricity supply disconnected. The rating plate on the hob shows the type of gas with which it is designed to be used. Connection to the mains gas supply or gas cylinder should be carried out after having checked that it is regulated for the type of gas with which it will be supplied. If it is not correctly regulated see the instructions in the following paragraphs to change gas setting. For liquid gas (cylinder gas) use pressure regulators which comply with the relevant national standards. Use only pipes, washers and sealing washers which comply with the relevant national standards. For some models a conic link is furnished to outfit for the installation in the countries where this type of link is obligatory; in picture 8 it is pointed out how to recognize the different types of links (CY = cylindrical, CO = conic). In every case the cylindrical part of the link has to be connected to the hob. [. . . ] Conexiunea la o surs de alimentare poate fi realizat de asemenea prin aezarea unui disjunctor omnipolar între aparat i sursa de alimentare care s suporte sarcina maxim conectat i care s respecte legislaia actual. Plita poate fi instalat în orice blat de lucru care rezist la o temperatur de pân la 100°C i are o grosime de 25-45 mm. dimensiunile cadrului în care poate fi incorporat plita sunt indicate în Figura 2. Dac exist un spaiu care este accesibil între plita incorporabil i cavitatea de sub aceasta, este recomandat s fie fixat un panou de izolare (din lemn sau un material similar) (Figura 3). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANDY CVG6BR4WPW




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANDY CVG6BR4WPW will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.