User manual CAME ZR22

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CAME ZR22. We hope that this CAME ZR22 user guide will be useful to you.


CAME ZR22 : Download the complete user guide (274 Ko)

Manual abstract: user guide CAME ZR22

Detailed instructions for use are in the User's Guide.

[. . . ] SAFETY PRECAUTIONS • Do not install the appliance if it is connected to the power supply. € The Installation and service/repair must be performed by a qualified technician, in compliance with the producer's instructions and following local safety norms. Do not repair or replace any parts of the appliance unless it is specifically written in the user instructions. € Make sure that the power supply cord is long enough to allow the right connection. [. . . ] Swing button FAN adjustment procedure Indoor fan speed alternates among High, Medium and Low each time this button is pressed. Press it once, the vertical adjustment louver swings to change vertical airflow direction. For horizontal airflow direction please refer to the chapter "Airflow direction control". 13 501932602028:Layout 1 1-12-2008 17:02 Pagina 14 Clock function You can adjust the real time by pressing CLOCK button, then using and buttons to get the correct time, press CLOCK button again: the real time is set. sLEEP mode SLEEP mode can be set in COOLING or HEATING operation mode. In SLEEP mode, • The appliance will stop operation automatically after operating for 8 hours. € Set temperature will rise by max 1°C if the appliance operates in cooling mode for 2 hours. € Set temperature will decrease by 3°C at most if the appliance operates in heating mode for 3 hours. *Note: In cooling mode, if room temperature is 26°C or above, set temperature will not change. oN JET mode • JET mode is used to start or stop fast cooling. Fast cooling operates at high fan speed, changing the set temperature automatically to 18°C. Note that operation will be abnormal, in this case unplug from the power supply and re-plug after 2-3 seconds. € This smell may come from another source such as furniture, cigarette etc, which is sucked in the unit and blown out with the air. € Normal behaviour caused by the flow of refrigerant in the air conditioner. € The sound may be generated by the expansion or contraction of the front panel due to temperature changes. Normal behaviour due to cool air discharged from indoor unit during COOLING or DRY operation mode. Does not run No cooling or heating air Ineffective control Does not operate immediately Peculiar smell A sound of running water Cracking sound Mist sprays from the outlet 17 501932602028:Layout 1 1-12-2008 17:03 Pagina 18 INSTALLATION INSTRUCTIONS Installation diagram Distance from wall should be over 50mm Distance from ceiling should be over 50mm Distance from the wall should be over 50mm Distance from floor should be over 2000mm Air intake distance from the wall should be over 250mm Air intake distance from the wall should be over 250mm Ai shor out uld let be dist ov anc er e f 50 rom 0m m the wa ll Over 250mm NOTE: The figure above is only a simple presentation of the unit, it may not match the external appearance of the product you purchased. Installation must be performed in accordance with the national wiring standards by authorized service people only. 18 501932602028:Layout 1 1-12-2008 17:03 Pagina 19 Select the best location Location for Installing Indoor Unit • Where there is no obstacle near the air outlet and air can be easily blown to every corner. € Observe the required distance from ceiling and wall according to the wiring diagram. € Keep the unit and remote control 1m or more from television, radio etc. € To prevent the effects of a fluorescent lamp, keep the unit as far as possible from it. [. . . ] € Power supply from Indoor unit, including 7K, 9K, 12K, 18K Model HEAT PUMP Indoor unit Terminal Brown Blue COOLING ONLY Outdoor unit Terminal Brown Blue Indoor unit Terminal Outdoor unit Terminal Brown Brown 1L N 1L N Power connecting cord 1 Brown Brown Blue Blue Blue Power connecting cord Blue Power connecting cord Yellow/Green Yellow/Green Yellow/Green Yellow/Green 23 501932602028:Layout 1 1-12-2008 17:04 Pagina 24 • Power supply from outdoor unit, including 24K Model For these models, the power supply is connected from outdoor unit, with a circuit breaker. HEAT PUMP Indoor unit Terminal Outdoor unit Terminal Gray COOLING ONLY Indoor unit Terminal Oran ge(G ray) Outdoor unit Terminal Oran ge(G ray) Brow n Blu e(B lac k) 3L 2L 1L Gray 3L 2L 1L L Black Brown Brown Black Power connecting cord 1 Brow n Brow n Blu e Brown k) lac e(B Blu re e n ow /G Power connecting cord ll Ye /G ow e re Ye ll n L N e Blu Ye llo w/ Gr ee n Power connecting cord Ye llo w /G re en Terminal N Terminal L N Power supply Power supply • Defrost Cable (for heat-pump air conditioner only, and it's an optional part) Defrost wire (indoor) Defrost wire (outdoor) Defrost cable (for heat pump models only) After connection, the defrost wire should be well wrapped with a wrapping tape and the connector should be put inside the unit. 24 501932602028:Layout 1 1-12-2008 17:04 Pagina 25 OUTDOOR UNIT INSTALLATION 1. Install Drain Port and Drain Hose (for heatpump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME ZR22




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CAME ZR22 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.