User manual CAMCO TECTON 14.2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CAMCO TECTON 14.2. We hope that this CAMCO TECTON 14.2 user guide will be useful to you.


CAMCO TECTON 14.2 : Download the complete user guide (997 Ko)

Manual abstract: user guide CAMCO TECTON 14.2

Detailed instructions for use are in the User's Guide.

[. . . ] TECTON USER MANUAL INFORMATION FOR USE FOR TECTON 38. 4, TECTON 32. 4, TECTON 24. 4, TECTON 28. 2, TECTON 22. 2 and TECTON 14. 2 TUM_GB_2004-200-R2_09-200 © Copyright 200 by CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Fischpicke 5, D-57482 Wenden, Germany Telephone +49 (0) 2762 408-0 P. USER MANUAL TECTON POWER AMP SERIES IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS ) Read the information for use (user manual). 2) Please keep this user manual in a safe place during the lifetime of the amplifier. Reselling of the amplifier is only possible if the user manual is available. Any changes made to the amplifier have to be documented in writing and passed on to the buyer in the event of resale. [. . . ] Switch the power switch to the Off position to make changes on the Mode Selector. When the amplifier is switched on again, the selected mode will operate. 3. 8 Wiring 3. 8. and XLR Connection XLR: Pin = Ground (or lifted via 5 resistor) (See 3. 5 Ground Lift) Pin 2 = Hot (inphase) Pin 3 = Cold (out of phase) Always use symmetrical (balanced) shielded cable to connect the amplifier. Input Channel B Input Channel A LINK B LINK A 2 3 2 3 3 2 3 2 SWITCH OFF THE AMPLIFIER BEFORE CHANGING MODES To Channel B To Channel A Input Ground Lift Input Ground Lift in position: grounded P. 4 USER MANUAL TECTON POWER AMP SERIES 3 INSTALLATION 3. 8. 2 Stereo Operation, 2 Channel Operation Two fully independent amplifier channels (normal operating mode). 3. 8. 4 Mono-Bridge Operation One-channel mono bridged operation. TECTON A TECTON Z *Zmin A B Z 2 *Zmin Z *Zmin 3. 8. 3 Parallel-Mono Operation Parallel operation of the two channels together. TECTON Zres 0. 5 *Zmin A The second channel processes the same input signal, but with reversed phase. The (single) load is connected between the two positive channel outputs using a suitable connected SPEAKON connector. While the total output of the amplifier remains the same, both the available output voltage and the minimum impedance that can be connected are doubled, as compared with stereo operation. Wiring to the speaker loads must conform to NEC Class 3 safety standards or its equivalent that meets all national and local electric codes. All customer specific cables may only be manufactured by qualified suppliers/personnel. All cabling or rewiring work must be carried out by qualified personnel. * Zmin = 2 for TECTON 28. 2, 22. 2 and 14. 2 * Zmin = 4 for TECTON 38. 4, 32. 4 and 24. 4 The output terminals of the two channels are configured in parallel using an internal relay. The (single) load is connected either to the output of channel A or to that of channel B (as if in stereo). While the total output of the amplifier remains the same and the output voltage level is also the same as in stereo operation, the minimum impedance that can be connected is reduced by half due to the fact that current capability is doubled. The channel B-Input is inactive ­ turn the volume of channel B down to zero. This mode is useful when, for example, 3 identical loudspeakers are to be operated with the same power. P. 5 USER MANUAL TECTON POWER AMP SERIES 4 OPERATION 3. 8. 5 SPEAKON Connection Both SPEAKON connectors are connected to channel A and channel B outputs. The pin configuration of the SPEAKON connectors is as follows: SPEAKON right: Pin + (View at the back) Pin Pin 2+ Pin 2SPEAKON left: (View at the back) WARNING !SPEAKON connectors marked with the lightning flash indicate high voltages that are potentially life threatening. Wiring to these terminals requires installation by an instructed person or the use of ready-made leads or cords. To prevent electric shock, do not operate the amplifier with any of the conductor portion of the speaker wire exposed. Channel A Channel A Channel B Channel B Channel B Channel B Channel A Channel A signal ground signal ground signal ground signal ground Pin + Pin Pin 2+ Pin 2- Input Channel A SPEAKON right NOTE: For reasons of safety and performance, use only high-quality fully insulated speaker cables of stranded copper wire. Use the largest wire size that is economically and physically practical, and make sure the cables are no longer than necessary. Input Channel B IMPORTANT: When connecting speaker cabinets in parallel, always use all the contacts in both SPEAKON connectors. If not, this may cause permanent damage to the connectors and considerably reduce performance. SPEAKON left P. 6 USER MANUAL TECTON POWER AMP SERIES 4 OPERATION 4. Volume Control A volume control with 4 notched settings controls the audio signal. These settings have been selected to correspond to human hearing characteristics (logarithmically) and therefore guarantee an optimal range of settings for practical applications. Each channel can be set individually except when operating in mono modes whereby only channel A is active. 4. . 3 Gain and Input Sensitivity The table shows input sensitivity per channel for a given gain and load. [. . . ] frequency / Different positions of HPF-Switch (Ch, Ch2) (Measurements of a typical performance) Figure 8. 4 Phase vs. frequency / Different positions of HPF-Switch (Ch, Ch2) (Measurements of a typical performance) 500 Hz k 2k 5k 0k 20k P. 26 USER MANUAL TECTON POWER AMP SERIES 8 MEASUREMENTS 300m 200m 00m 50m Ohm 20m 0m 5m 000 800 damping factor 600 400 200 2m 20 50 00 200 500 Hz k 2k 5k 0k 20k 0 20 50 00 200 500 Hz k 2k 5k 0k 20k Figure 8. 5 Output impedance vs. frequency @ Amp RMS injected current (Ch, Ch2) equivalent m + 2, µH (Measurements of a typical performance of TECTON 32. 4) -20 -30 -40 -50 -60 dB -70 -80 -90 -00 -0 -20 00u 200u 500u m 2m 5m 0 m 20m 50m 00m 200m 500m Vrms 2 5 Figure 8. 7 Damping factor into 8 (Ch, Ch2) equation: damping factor = loaded impedance / amplifier output impedance (Measurements of a typical performance of TECTON 32. 4) -20 -30 -40 -50 -60 dB -70 -80 -90 -00 -0 -20 20 50 00 200 500 Hz k 2k 5k 0k Figure 8. 6 THD+N @ kHz, 8 load vs. input voltage (Ch, Ch2) (Measurements of a typical performance of TECTON 32. 4) Figure 8. 8 THD+N vs. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CAMCO TECTON 14.2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CAMCO TECTON 14.2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.