User manual BOSCH PWS 9-125

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BOSCH PWS 9-125. We hope that this BOSCH PWS 9-125 user guide will be useful to you.


BOSCH PWS 9-125 : Download the complete user guide (4537 Ko)

Manual abstract: user guide BOSCH PWS 9-125

Detailed instructions for use are in the User's Guide.

[. . . ] Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. The term “power tool” in the warnings refers to your mainsoperated (corded) power tool or battery-operated (cordless) power tool. Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. unmodified plugs and matching outlets will reduce risk of electric shock. [. . . ] The vibration emission level given in this information sheet has been measured in accordance with a standardised test given in EN 60745 and may be used to compare one tool with another. The declared vibration emission level represents the main applications of the tool. However if the tool is used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase the exposure level over the total working period. An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period. Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep hands warm, organise work patterns. Technical Data Angle Grinder Article number Rated power input Output power Rated speed Speed control adjustment Grinding disc diameter, max. ) of grinder spindle Constant electronic control Speed preselection Weight according to EPTA-Procedure 01/2003 Protection class PWS 8-125 CE 3 603 C99 B. 800 425 11000 2800 – 11000 125 M 14 22 PWS 9-125 CE 3 603 C99 A. 900 450 11000 2800 – 11000 125 M 14 22 W W min-1 min-1 mm mm kg The values given are valid for a nominal voltage [U] of 230 V. For different voltages and models for specific countries, these values can vary. 0 /II Please observe the article number on the type plate of your machine. Declaration of Conformity We declare under our sole responsibility that the product described under “Technical Data” is in conformity with the following standards or standardization documents: EN 60745 according to the provisions of the directives 2011/65/EU, 2004/108/EC, 2006/42/EC. Eckerhard Strötgen Senior Vice President Engineering Director Engineering PT/ESI Assembly Mounting the Protective Devices Before any work on the machine itself, pull the mains plug. Note: After breakage of the grinding disc during operation or damage to the holding fixtures on the protection guard/power tool, the machine must promptly be sent to an after-sales service agent for maintenance for addresses, see section „After-sales Service and Customer Assistance“. Book Page 19 Monday, October 10, 2011 9:22 AM English | 19 Protection Guard for Grinding Place the protection guard 7 onto the spindle collar of the machine until the encoding keys of the protection guard agree with the spindle collar. Press the protection guard 7 onto the spindle collar until the shoulder of the protection guard is seated against the flange of the machine, and turn the protection guard until it can clearly be heard to engage. Adjust the position of the protection guard 7 to the requirements of the work process. For this, press the release lever 1 upward and turn the protection guard 7 to the required position. Always adjust the protection guard 7 in such a manner that all 3 red cams of release lever 1 engage into the corresponding notches of the protection guard 7. Adjust the protection guard 7 in such a manner that sparking is prevented in the direction of the operator. [. . . ] Book Page 41 Monday, October 10, 2011 9:22 AM Português | 41 Se não for possível evitar o funcionamento da ferramenta eléctrica em áreas húmidas, deverá ser utilizado um disjuntor de corrente de avaria. Book Page 44 Monday, October 10, 2011 9:22 AM 44 | Português Destravar o interruptor de ligar-desligar e colocá-lo na posição desligada, se a alimentação de rede for interrompida, p. Undgå at bære el-værktøjet med fingeren på afbryderen og sørg for, at el-værktøjet ikke er tændt, når det sluttes til nettet, da dette øger risikoen for personskader. Slibeskiver for afsplintninger og revner, slibebagskiver for revner, slid eller stærkt slid, trådbørster for løse eller brækkede tråde. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BOSCH PWS 9-125




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BOSCH PWS 9-125 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.