User manual BLUE SKY SAT 8

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BLUE SKY SAT 8. We hope that this BLUE SKY SAT 8 user guide will be useful to you.


BLUE SKY SAT 8 : Download the complete user guide (1572 Ko)

Manual abstract: user guide BLUE SKY SAT 8

Detailed instructions for use are in the User's Guide.

[. . . ] Compact Mid-Field active studio monitor SAT 8 Blue Sky International 70 Sea Lane, Farmingdale, New York, 11735 USA · T: +1 516 249 1399 · F +1 516 249 8870 www. abluesky. com SAT 8 USER MANUAL · CONTENTS Important 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Safety Instructions Page 3 SAT 8 Introduction Page 4 Important Notes About the SAT 8 and This Manual Page 4 What is included?Page 4 SAT 8 Features Overview Page 5 Page 6 & 7 A Tour of the SAT 8 Amplifier & Electronics SAT 8 Mounting and Placement Page 8 System Signal Flow & Connections Page 9 Quick 2. 1 System Setup Instructions Page 10 Expanded Calibration Guide Page 11 Subwoofer Placement Guide Page 12 Technical Information & Dimensions Page 13 Measurement Data Page 14 Factory Service Instructions Page 16 General Contact Information Page 16 Recycling Information Page 16 Page 2 · User Manual - Contents USER MANUAL · SAFETY INSTRUCTIONS SAT 8 1 READ INSTRUCTIONS - Read all safety and operating instructions before operating this product. RETAIN INSTRUCTIONS - Retain these safety and operating instructions for future reference. 12. 2. SERVICING - Do not attempt to service this product yourself. Opening or removing covers, including any over bottom or side speaker drivers, may expose you to dangerous voltage or other hazards. [. . . ] AVIS: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR SUB OUT to SUB IN (optional) 115/230 50/60 Hz 800W designed in the USA WARNING: SET VOLTAGE SWITCH BEFORE TURNING ON T 4AL 250V FOR 230V INPUT T 8AL 250V FOR 115V INPUT made in China SUB 212, SUB 12 or SUB 15 (SUB 212 shown) R Optional additional subwoofers RIGHT IN RIGHT OUT LEFT IN LEFT OUT SUB IN SUB OUT MUTE blue sky international 70 Sea Lane Farmingdale, New York, 11735 USA www. a bluesk y. com PHASE 0 SUB GAIN REF -3 OFF AUTO -6 -9 -12 -15 -18 -24 sub 212 | 400-watt active subwoofer OFF 180 RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION ! VOLTAGE SELECTOR ON Replace Only With Same Rating and Type WARNING:To reduce the risk of fire or electrical shock, do not expose this equipment to rain or moisture. AVIS: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR designed in the USA WARNING: SET VOLTAGE SWITCH BEFORE TURNING ON T 4AL 250V FOR 230V INPUT T 8AL 250V FOR 115V INPUT 115/230 50/60 Hz 800W made in China Optional additional subwoofers (for best results, use identical subs) 2. 1 SYSTEM SIGNAL FLOW & CONNECTIONS Above is a simple diagram showing how a SAT 8 / SUB 212 system may be wired for a stereo applications. The system shows a full-range source (the console) is wired to a SUB 212 subwoofer and from there the subwoofer outputs are connected to the inputs on the SAT 8. Multiple Subs: The diagram above also shows the optional use of multiple subwoofers. Multiple subwoofers can be used to increase SPL and improve the LF response of the system, by placing the subwoofers so as to smooth out the LF response at the mix / monitoring position. Please note that we recommend that you run the subs in MONO, by using the subwoofer out on the main sub and then feeding the next sub in the chain. We do not recommend running stereo subwoofers, because the LF response in the room will not be as consistent using this method. This is because electrical summation of the LF signals (as is done with bass-management using a mono subwoofer / LF signal), is a very predictable and repeatable way to get consistent LF response. LF phase issues between channels are resolved in the most absolute and accurate way - electrically. Cable and connector wiring: Use high-quality, shielded cables to connect your console, workstation or other sources to your SAT 8 / SUB 212 system. Foil-shielded cables, such as Belden 8451, 8761, or 9501 should do quite well. Other high quality cables are available and those that incorporate better shielding will yield an overall higher noise rejection, lowering your systems susceptibility to external interference. Another important tip to keep in mind when wiring your system is to route all line level cables away from the AC and other power sources, this will reduce the probability of having AC hum emanating from your monitoring system. User Manual · System Signal Flow & Connections · Page 9 USER MANUAL · 8 · QUICK 2. 1 SYSTEM SETUP INSTRUCTIONS 1. With the gain control on the SAT 8 set to the reference mark, a 200mV (-11. 7dBu) pink noise signal, with a bandwidth of 500 to 2kHz, will yield 90dB SPL at 1 meter. With the gain on the SUB 12 set to the reference mark, or -9dB on the SUB 15, 100mV (-13. 7dBu) pink noise signal, with a bandwidth of 40Hz to 80Hz, on one of the inputs, will yield 90dB of output at 1 meter. Because most control rooms have some gain at low frequencies a good starting point for the subwoofer level is -3dB from the reference position. If you are using multiple subs, the gain may need to be even lower than this (depends on the acoustics of the studio and the placement of the subs). For more information with regard to the controls, please see the manual that came with the SUB 12 or SUB 15, and page 6 & 7 of this manual [A Tour of the SAT 8 Amplifier & Electronics]. The SAT 8, SUB 212, SUB 12 and SUB 15 are compatible with balanced XLR connectors / cables. The total number of XLR cables needed will depend on the system configuration. However for a basic 2. 1 system, with one sub, you need a minimum of four XLR Cables. For more information on connecting your system, please see page 9 [System Signal Flow & Connections]. [. . . ] (20. 86 kg) 1" Tweeter Dual Ring Radiator Diaphragm with integral waveguide High-power ferrite motor structure Fully video shielded 4" Hemispherical Midrange 2" voice coil Cast aluminum frame Neodymium vented motor structure Copper shorting ring Aluminum alloy cone Fully video shielded 8" Hemispherical Woofer 8" high excursion woofer with vented motor Cast aluminum frame 2" voice coil Mica filled polypropylene cone w/ Rubber surround Fully video shielded 13. 00 330 mm 11. 25 286 mm 11. 60 295 mm 20. 88 530 mm 10. 83 275 mm 5. 00 127 mm 2. 75 70 mm 4. 25 108 mm 2. 75 70 mm 4. 25 108 mm 2. 66 68 mm 1/4 x 20 inserts 5. 00 127 mm 3. 05 77 mm User Manual · Technical Specifications & Dimensions · Page 13 USER MANUAL · 12 · MEASUREMENT DATA Conditions: All SAT 8 measurements were made outdoors on a 58 inch stand at a distance of 1 meter. Since a 58 inch stand is not tall enough for accurate low-frequency measurements, a 1 meter ground plane measurement was also made and spliced in at 125 Hz on all measurements, to generate full frequency response. SAT 8 Page 14 · User Manual · Measurement Data USER MANUAL · FACTORY SERVICE INSTRUCTIONS, GENERAL CONTACT DETAILS & RECYCLING INFORMATION SAT 8 13. versions of Blue Sky products is available only from our authorized distributor, Group One Ltd. , located in Farmingdale, New York. (Service for Blue Sky products outside the United States can be obtained through local dealers or distributors. ) If your monitor needs service, follow these instructions: 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BLUE SKY SAT 8




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BLUE SKY SAT 8 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.