User manual BIAMP VOCIA OUTPUT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BIAMP VOCIA OUTPUT. We hope that this BIAMP VOCIA OUTPUT user guide will be useful to you.


BIAMP VOCIA OUTPUT : Download the complete user guide (2785 Ko)

You may also download the following manuals related to this product:

   BIAMP VOCIA OUTPUT SHEET (278 ko)

Manual abstract: user guide BIAMP VOCIA OUTPUT

Detailed instructions for use are in the User's Guide.

[. . . ] The VO-4 features embedded DSP and on-board memory to process and store all device-specific configuration information locally and includes comprehensive, fixed-chain, digital-signal processing. As part of the Vocia system, the VO-4 meets paging requirements for facilities of all sizes. FEATURES · Converts digital to analog · Four removable terminal block connectors for line-level outputs · Four control inputs and four control outputs · Software-configurable local audio signal processing, including gain, filters, and compressor/limiter · Rotary switches for unit identification · Power Over Ethernet (PoE) · CobraNet audio/control with dynamic use of available bundles, plus power over single Ethernet cable · Status LEDs to indicate signal and clip · CE marked and RoHS compliant · Covered by BiAmP Systems' warranty 3 VO-4 frOnt panel Setup and Use The Vocia software provides an intuitive interface for configuration, DSP equalization, and programming of the VO-4. [. . . ] All VO-4 units must have a unique Device iD to function properly within a Vocia Paging World (i. e. , it is not possible to have two VO-4 units with the same Device iD of hex 07). To assign a Device iD of hex 07, turn the LSB switch to 7 and leave the mSB switch on 0. To create an iD of hex B7, turn the LSB switch to 7 and turn the mSB switch to B. Device iD switches should be set using a 0. 1 inch (2. 5mm) to 0. 12 inch (3. 0mm) flat blade screwdriver. more information on setting iDs and the hexadecimal numbering scheme used in Vocia can be found in the Vocia Help File. Please note: Changes made to the Device iD while connected to the network require a power cycle in order to take effect. All CobraNet routing and bundle assignments are processed by the Vocia devices locally. Vocia devices are currently not interoperable with non-Vocia devices. 5 VO-4 rear panel cOntrOls This connection carries control data, power, and digital audio over CobraNet. The maximum distance between any unit and an Ethernet switch is 328 feet (100 meters) when using copper cabling. Additional Ethernet switches and/or fiber-optic cable can be used to further extend distances between units on a network. Please note that CobraNet limits network extensions to seven hops (one-way transmissions) within a network. If other network traffic shares an Ethernet switch with the Vocia network, a managed switch should be used with separate VLANs. All Ethernet wiring is to be done using shielded CAT5, CAT5e, CAT6, or CAT7 cable. VO-4 BIAMP SYSTEMS Designed in Australia Assembled in USA N24138 Model VO-4 YEL:in use/conductor GRN:link/act Device ID GND Control Outputs Control Inputs Audio Outputs CobraNet® PoE IEEE 802. 3af Class 0 MSB LSB C NC NO C NC NO 1 2 C NC NO 3 C NC NO 4 1 2 3 4 10V (100mA) +1 +2 +3 +4 Ethernet switch with PoE VO-4 BIAMP SYSTEMS Designed in Australia Assembled in USA N24138 Model VO-4 YEL:in use/conductor GRN:link/act Device ID GND Control Outputs Control Inputs Audio Outputs CobraNet® PoE IEEE 802. 3af Class 0 MSB LSB C NC NO C NC NO 1 2 C NC NO 3 C NC NO 4 1 2 3 4 10V (100mA) +1 +2 +3 +4 Ethernet switch without PoE PoE injector AC Power 6 VO-4 rear panel cOntrOls Control Outputs The Control Outputs, labeled 1 through 4, are isolated, voltage-free, software-configurable relay outputs. (NO): normally open (connected to C when relay is energized) Control Inputs The Control inputs are labeled as follows: 1. (10V): 10V reference voltage (when used as a switch input, a switch must be connected between the input and logic common terminal) Audio Inputs Four plug-in barrier strip connectors provide analog audio signal output. [. . . ] No agent, employee, distributor or dealer of BiAmP Systems is authorized to modify this warranty or to make additional warranties on behalf of BiAmP Systems. Statements, representations or warranties made by any dealer do not constitute warranties by BiAmP Systems. BiAmP Systems shall not be responsible or liable for any statement, representation or warranty made by any dealer or other person. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP VOCIA OUTPUT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP VOCIA OUTPUT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.