User manual BIAMP T500 AND T1000 SERIES

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BIAMP T500 AND T1000 SERIES. We hope that this BIAMP T500 AND T1000 SERIES user guide will be useful to you.


BIAMP T500 AND T1000 SERIES : Download the complete user guide (1092 Ko)

Manual abstract: user guide BIAMP T500 AND T1000 SERIES

Detailed instructions for use are in the User's Guide.

[. . . ] Install product in accordance with the manufacturer's instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. CAUTION Installation of the apparatus should be made by a qualified installation person and should conform to all applicable local codes. Modifications and optional equipment information referenced in this manual is for use by qualified installation and service personnel only. [. . . ] The DC supply must be wired into both power supply inputs, either from redundant supplies or from a single supply wired in parallel to the two inputs. If 24V is not supplied to both inputs, a loss-ofsupply fault will be reported. If a VA-4030e or VA-2060e amplifier is required to operate without a 24V supply, the Auxiliary supply fault monitoring must be disabled in Vocia software. A loss of supply fault is indicated via the Vocia software and by a blinking yellow Amp Fault indicator on the front panel of the affected device. The power supplies used for the amplifier must meet the voltage range and power requirements detailed in the specifications table below. Local standards, norms or codes may require the use of certified power supplies and may require observance of minimum on-battery running times both for standby and maximum power conditions. Note that dual redundant power supplies must each independently meet the total power requirements of the amplifier. The pluggable terminal blocks provided will accommodate wire sizes from 12-18 AWG. External over-current protection must be provided, according to the current carrying capacity of the connecting wires, and in no case greater than 30 Amps. Do not ground or connect to chassis either the positive or negative Auxiliary Power connections. All CobraNet routing and bundle assignments are processed by the Vocia devices locally. Similarly, two such relays per channel are presented for the VA-2060 and VA-2060e (relays operate in tandem). The PAR connections are labeled as follows: C: Relay Common NC: Normally Closed NO: Normally Open Page Active Relay: VA-4030e and VA-2060e 8 VOCIA AMPlIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e REAR PANEl Amplifier Output Connections CAUTION: All speaker wiring connections and output load selection should be made by qualified personnel and with the amplifier power removed. Please refer to a qualified electrician or other qualified person according to local codes. Transformer Load Selection The required amplifier output load is configured via the use of a recessed indented selector above the amplifier speaker output connectors. The switch is designed to be operated with a flat blade screwdriver (blade width 0. 1"- 0. 25"/ 2. 5mm - 6. 4mm). Selection can be made between 4 or 8 for Low Impedance connections and 25V, 70V or 100V for Constant Voltage loads. If an amplifier channel is unused (i. e. , has no load) do not configure the channel in Vocia software to pass audio. Speaker Connection To minimize power loss, use a speaker cable of appropriate gauge for the load impedance. For long speaker cables, to minimize high frequency loss, choose a low capacitance cable. Use the supplied plug-in barrier strip connectors to connect loudspeaker level outputs. If stranded speaker wire is used, be sure to incorporate all strands into the connector, as stray strands can short to the adjacent terminal or chassis. Do not leave excessive bare wire outside the terminals, as this can lead to shorts. [. . . ] In this configuration channel 4 will act as a redundant backup for channel 1, 2 or 3. 1:1 or 3:1 channel failover is triggered by one of the following conditions: Heatsink fault (over temperature) Short circuit fault Channel failure fault ELD-1/speaker line fault if enabled in software The redundant channel may be wired in parallel to the existing speaker line or connected to a redundant speaker line. The primary amplifier module will resume control after the fault condition is cleared and the unit is re-powered. Channel-to-Channel Example: Single Wiring, Parallel Wiring and Redundant Speaker Topology 3:1 Failover Speaker Wiring 11 VOCIA AMPlIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e SPECIFICATIONS Vocia Amplifier 2060 / 2060e / 4030 / 4030e Message Memory: Network Audio: Network Connections: Analog Inputs: Nominal Input Range: Maximum Input Level: Equivalent Input Noise: Dynamic Range: Input Impedance: Phantom Power: Frequency Response: Signal to Noise Ratio: THD + Noise: Rated Output Power: VA-2060: VA-2060e: VA-4030: VA-4030e: Supported Loads: Low Impedance: Constant Voltage: Output Configuration: Output DC Offset: PAR Relays Form: Max Operating Voltage: Max Operating Current: 5. 625 MB 20-bits, 48kHz, 5-1/3 ms (fixed) RJ45 with shielded Ethernet cable (CAT5, CAT5e, CAT6 or CAT 7) (VA-2060e and VA-4030e) Per Channel -66dBu to 0dBu +24dBu (max Gain) >-125dbu >94dB 8k +48V DC 40Hz-20kHz +/- 2dB >88dB, unweighted <0. 5% 50Hz-100Hz <0. 3% 100Hz-10kHz 2x 60W RMS, total 120W 2x 60W RMS, total 120W 4x 30W RMS, total 120W 4x 30W RMS, total 120W 4, 8 25V, 70V or 100V Transformer Coupled (ground free) <100mV Single Form C contact 125V AC, 60V DC 100mA AC, 1A DC Power: AC (all amplifiers): DC (VA-2060e and VA-4030e): Continuous power rating Peak Power rating DC Range: Overall Dimensions: Height: Width: Depth: Weight: VA-2060: VA-2060e: VA- 4030: VA- 4030e: Compliance: 100V-240V AC, 50H 60 Hz Nominal 24V DC 60 Watts 150 Watts 18V-30V; <100mV Ripple 3. 25 in (82. 5mm) 19 in (483mm) 14. 2 in (360mm) 24. 7lbs (11. 2kg) 24. 9lbs (11. 3kg) 26. 0lbs (11. 8kg) 26. 2lbs (11. 9kg) FCC Part 15B (USA) EN 54-16 pending (Europe) UL 60065 and C-UL listed (USA & Canada) CCC pending (China) KC pending (Korea) C-Tick (Australia) RoHS Directive (Europe) 2002/95/EC (Europe) Environment Ambient Operating Temperature Range: 18-108 degrees F (-8 42 C) Ambient Intake: Humidity: 0 100% non-condensing Altitude: 0 10, 000 Feet MSL 12 VOCIA AMPlIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e blOCk dIAgRAM 4030e and 2060e Amplifiers 4030 and 2060 Amplifiers 13 VOCIA AMPlIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e CURRENT dRAW ANd hEAT OUTPUT VA-4030 and VA-4030e Specifications IDLE Total Output Power (Watts) 30 60 90 120 Channels Used 1 2 3 4 Input Power Watts 30 30 30 30 BTU /hr 102 102 102 102 1/8 POWER PINK NOISE Input Power Watts 36 41 47 54 BTU /hr 110 114 122 133 1/3 POWER PINK NOISE Input Power Watts 46 62 77 93 BTU /hr 123 143 160 181 FULL POWER SINE WAVE Input Power Watts 88 133 179 217 BTU /hr 198 242 304 331 VA-2060 and VA-2060e Specifications IDLE Total Output Power (Watts) 60 120 Channels Used 1 2 Input Power Watts 27 27 BTU /hr 92 92 1/8 POWER PINK NOISE Input Power Watts 38 50 BTU /hr 104 119 1/3 POWER PINK NOISE Input Power Watts 60 90 BTU /hr 136 171 FULL POWER SINE WAVE Input Power Watts 119 213 BTU /hr 201 317 14 VOCIA AMPlIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e WARRANTY BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL 1. BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to the terms and conditions set forth below. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP T500 AND T1000 SERIES




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP T500 AND T1000 SERIES will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.