User manual BIAMP RACKMAX IIEX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BIAMP RACKMAX IIEX. We hope that this BIAMP RACKMAX IIEX user guide will be useful to you.


BIAMP RACKMAX IIEX : Download the complete user guide (1913 Ko)

You may also download the following manuals related to this product:

   BIAMP RACKMAX IIEX annexe 1 (1492 ko)

Manual abstract: user guide BIAMP RACKMAX IIEX

Detailed instructions for use are in the User's Guide.

[. . . ] The LSI-16e may accept up to three sources of power: main power is from an external, standards compliant and battery backed 24V DC source; the LSI-16e can also utilize Power over Ethernet (PoE) delivered via either of its two network ports. [. . . ] The LSI-16e uses Ethernet-based control protocols to function within a Vocia system. FEATURES · Parallel I/O ports for direct interface with fire alarm and emergency equipment · 8 monitored I/O and 8 control inputs · Redundant network connection and power supply options · Power and data over a single Ethernet cable · Local storage of configuration data · Rotary switches for unit identification · Up to 4 discrete emergency inputs · 16 additional general purpose inputs can be programmed to play an emergency message, enable zone reset or zone silence; maximum of 10 inputs can be assigned per emergency zone · Each general purpose input can be programmed as TTL, high range or monitored high range · General purpose inputs allow monitoring for short to ground and open circuit · Up to 500 virtual inputs via RS232 or Ethernet · Provides system health monitoring via RS232 or Ethernet · Status LEDs · Rack mountable (1RU) · CE marked and RoHS compliant · EN 54-16 certification pending · Covered by Biamp Systems' warranty ARCHITECTS & ENGINEERS SPECIFICATION The life safety interface shall be designed exclusively for use with Biamp® Vocia systems. The life safety interface shall provide a networked emergency interface to third-party emergency and alarm systems. The life safety interface shall be powered from a certified 24V DC power source or over Ethernet (PoE) via either of two network ports. The enhanced life safety interface shall be a Vocia LSI-16e. Biamp Systems 9300 S. W. Gemini Drive, Beaverton, Oregon 97008 U. S. A. (503) 641-7287 www. biamp. com Life Safety Interface 16e SPECIFICATIONS System Fault Relay: Type: Load: Maximum operating voltage: Maximum operating current: Maximum switching capacity: Minimum permissible load: Control Inputs: Number: Type: Cathode presented at input ­ pull low to enable. Sink Current: Min: Max : Maximum Terminal Voltage: Isolation: Single `Form C' voltage-free SPST change-over contact Resistive 125VAC, 60VDC 600mA AC, 1A DC 37. 5VA, 30W 10µA @ 10mVDC Eight Opto Isolator LED 1mA 6mA 24V 3kV TTL Logic High: TTL Hysteresis: Input Transient Protection: Input Isolation: RS232 Port: Type: Baud Rate: Connection: Power: Main: PoE: Base Dimensions: Height: Width: Depth: Weight: Ambient Operating Temperature Range: Compliance: 2-5V 1V ± 20% ± 8KV peak 500V RMS (isolation from LSI-16) DTE 57600 RJ45 with shielded Ethernet/PoE cable (Cat5, Cat5e, Cat6 or Cat7) 24V DC 15W 802. 3af Class 3 1. 75 inches (44. 5mm) 19 inches (483mm) 10 inches (254mm Approx 6. 4 lbs. [. . . ] (2. 8kg) 32-113 degrees F (0-45 degrees C) FCC Part 15B CE marked EN 54-16 certification pending RoHS Directive UL 60065 Listed, E215636 C-UL Listed, E215636 C-Tick, N24138 (Australia) Monitored I/O: Number: Eight Type: FET switch, open drain (low side driver) Maximum Continuous Current: 0. 35A Current Limit: 0. 8A Maximum External Supply: 35V VMon Input Shutdown: 35V General Purpose Inputs: Number: High Range Logic Low: High Range Logic High: High Range Hysteresis: TTL Logic Low: 16 0-11V DC 12-30V DC 1V ± 20% 0-0. 8V Life Safety Interface 16e BACK PANEL BIAMP SYSTEMS Designed in Australia Assembled in USA YEL: in use GRN :link/act 10 0832-CPD-1401 N24138 52SJ Model LSI-16 Option A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Option B Device ID GND 1 PoE IEEE 802. 3af Class 3 2 MSB LSB 1 2 56 34 Monitored Outputs 7 8 10V 1 2 3 4 5 Control Inputs 6 7 8 C NC NO System Fault RS232 Power 24V 15W (100mA) Class 2 or LPS Life Safety Interface 16e BLOCK DIAGRAm LEDs ID Switches Vocia System PoE 24V DC Host Processor 8 Control Inputs 8 Monitored Outputs 16 General Purpose Inputs Biamp Systems 9300 S. W. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP RACKMAX IIEX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP RACKMAX IIEX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.