User manual BIAMP MIXPAK

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BIAMP MIXPAK. We hope that this BIAMP MIXPAK user guide will be useful to you.


BIAMP MIXPAK : Download the complete user guide (1675 Ko)

You may also download the following manuals related to this product:

   BIAMP MIXPAK annexe 1 (224 ko)

Manual abstract: user guide BIAMP MIXPAK

Detailed instructions for use are in the User's Guide.

[. . . ] Under normal conditions, all LED's will remain green once power-up sequence has completed. 5. Assign IP address to PC PC must have a unique IP address before it can communicate with an Audia device. Right Click My Network>Properties>Local Area Connection>Right Click Properties>TCP/IP>Properties IP address should be 192. 168. 1. x (x=1-254) Subnet mask should be 255. 255. 255. 0 Click Ok when complete Close My Network 6. Connect PC to network Attach a "straight-through" Ethernet cable from PC 10/100baseT network card to a 10/100baseT Ethernet switch. [. . . ] "Straight-through" Ethernet cables connect transmit pins directly to receive pins (pin 1 to pin 1, pin 2 to pin2, pin 3 to pin3, etc. ). You can easily determine if an Ethernet cable is "straight-through" by looking at the conductors on the RJ-45 connectors. If the wiring is identical on both ends, it is a "straight through" Ethernet cable. 7. Connect Audia device to network Connect one Audia device to network using "straight through" Ethernet cable attached from the rear panel Ethernet jack to the 10/100baseT Ethernet switch. 8. Connect to network with Audia software Open Audia software then connect to network. Assign IP address to Audia device All Audia units ship from the factory with an assigned IP address of 192. 168. 1. 101. When using more than one device in a system, each device must have a unique IP address. Audia device IP addresses must be different from any PC IP address that will be used in this system. File>Network>Perform Audia Device Maintenance>Select desired Audia device>Set IP address IP address should be 192. 168. 1. x (x=1-254) Subnet mask should be 255. 255. 255. 0 Default gateway should be 0. 0. 0. 0 Click Ok when complete Close Device Maintenance when complete Note: To avoid conflict issues that occur when connecting multiple Audia devices with the same IP number, be sure to only connect one Audia device at a time to the Ethernet switch when assigning IP addresses. 10. Repeat steps 6-8 until all Audia devices in system have been connected to network and assigned a unique IP address. 11. As a condition to receiving the benefits of this warranty, you must provide BIAMP Systems with documentation that establishes that you were the original purchaser of the products. Such evidence may consist of your sales receipt from an authorized BIAMP Systems dealer. Transportation and insurance charges to and from the BIAMP Systems factory for warranty service shall be your responsibility. This warranty will be VOID if the serial number has been removed or defaced; or if the product has been altered, subjected to damage, abuse or rental usage, repaired by any person not authorized by BIAMP Systems to make repairs; or installed in any manner that does not comply with BIAMP Systems' recommendations. Electro-mechanical fans, electrolytic capacitors, gooseneck microphones, cords connecting handheld microphones, hard-drives, displays, and normal wear and tear of items such as paint, knobs, handles, keypads and covers are not covered under this warranty. This warranty is in lieu of all other warranties, expressed or implied. BIAMP Systems disclaims all other warranties, expressed or implied, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose. The remedies set forth herein shall be the purchaser's sole and exclusive remedies with respect to any defective product. No agent, employee, distributor or dealer of BIAMP Systems is authorized to modify this warranty or to make additional warranties on behalf of BIAMP Systems. Statements, representations or warranties made by any dealer do not constitute warranties by BIAMP Systems. [. . . ] No agent, employee, distributor or dealer of BIAMP Systems is authorized to modify this warranty or to make additional warranties on behalf of BIAMP Systems. Statements, representations or warranties made by any dealer do not constitute warranties by BIAMP Systems. BIAMP Systems shall not be responsible or liable for any statement, representation or warranty made by any dealer or other person. No action for breach of this warranty may be commenced more than one year after the expiration of this warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP MIXPAK




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP MIXPAK will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.