User manual BIAMP DRC 4 4

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BIAMP DRC 4 4. We hope that this BIAMP DRC 4 4 user guide will be useful to you.


BIAMP DRC 4 4 : Download the complete user guide (274 Ko)

You may also download the following manuals related to this product:

   BIAMP DRC 4 4 annexe 2 (624 ko)

Manual abstract: user guide BIAMP DRC 4 4

Detailed instructions for use are in the User's Guide.

[. . . ] DRC 4+4 Digital Remote Control Operation Manual ® 6/15/98 Biamp Systems, 10074 S. W. (503) 641-7287 http://www. biamp. com an affiliate of Rauland-Borg Corp. DRC 4+4 TABLE OF CONTENTS Front Panel Features Rear Panel Features Controls Options Logic Outputs Configuration Software PC Control pg. 19 Specifications Warranty o four channels of internal VCA (voltage controlled amplifiers) o four control voltages for external VCAs (ADVANTAGE RCII) o four logic outputs for controlling external switching circuits o four "preset mixes", plus "current mix", stored in memory o "preset mixes" include all VCA & control voltage settings o remote control of volumes, mutes, presets, & logic outputs o remote control via infrared, wall-mount, and/or computer o built-in infrared receiver with infrared transmitters optional o wall-mount controls & remote infrared receivers optional o wall-mounts & receivers install up to 2000 feet from system o internal jumper strap allows infrared receiver to be bypassed o RS-232 serial port provides computer control interface o remote control from up to five locations is made possible o TRS 1/4" jacks provide input, output, & patching for VCAs o DC Out jack powers external VCA units (ADVANTAGE® RCII) o external VCAs can be "grouped" to a single control voltage o internal VCAs can be "strapped" in pairs for stereo control o +10 Volt standard allows interface with analog lighting systems o remote commands programmable for custom applications. o logic output response programmable to twelve custom modes o PC control software for Windows 95 & serial cable included o optional remote display panels indicate levels and presets o covered by Five-Year "Gold Seal" Warranty o marked and UL / C-UL listed power source ® ® INTRODUCTION The ADVANTAGE® DRC 4+4 Digital Remote Control provides audio level and mute functions via infrared, wall-mount, and/or computer remote control. [. . . ] When a logic output goes on, the associated front panel LED will light. From the factory, access to the four logic outputs is available only through Configuration (see Configuration on page 8). During Configuration, the logic outputs can be individually assigned to independent control buttons. Also during Configuration, the way the individual logic outputs respond to a control button can be changed. There are twelve possible logic output responses: 1) `turn off' (push-off); 2) `turn on' (push-on); 3) `toggle' (push-on/push-off); 4) `push-button' (momentary push-on); 5) `repeat' (momentary repeating pulse); 6) "1/20 second" (single pulse); 7) `1/10 second' (single pulse); 8) "1/5 second" (single pulse); 9) `1/4 second' (single pulse); 10) "1/2 second" (single pulse); 11) "1 second" (single pulse); 12) `2. 5 second' (single pulse). Each logic output can be configured individually to any control button and to any response. In addition, special `Configuration Options" can be programmed so that Logic Outputs 1~4 "follow" the mute function on Channels 1~4, or that the status of the four Logic Outputs can be stored in memory as part of the Preset Mixes. Each logic output is an NPN transistor with the collector being the output and the emitter being ground (see diagram below). When a logic output is turned on, the transistor provides a path for DC current to flow. To activate external relays, an external power supply must be used (see diagram below). The logic output transistors are rated up to a maximum of 24 VDC and 50 mA per output (24 volt relay coils maximum). When using the logic outputs to control relays, protection diodes must be used to suppress high voltage transients that are generated when the relays turn off (see diagram below). Any of the 1N4004 family of diodes (1N4001, 1N4002, 1N4003, 1N4004, 1N4005, 1N4006, 1N4007, or equivalent) will provide proper protection. A 12 Volt Power Supply (#929-0011-00), 12 Volt Relays (#520-0064-00), and 1N4004 Diodes (#190-000309) are available from Biamp Systems. When a logic output goes on, the associated relay may be wired to perform on, off, or "A/B" switching functions. To use a logic "on" command to turn on (or activate) a device, wire across the "normally open" relay contacts, in series with the device (or control voltage source). To use a logic "on" command to turn off a device (or speaker), wire across the "normally closed" relay contacts, in series with the device (or control voltage source). To use a logic "on" command to select between "A" or "B" signals (inputs or outputs), wire one to the "normally closed" relay terminal and the other to the "normally open" relay terminal, with the common relay terminal providing the feed (input or output). 12345 6789 serial port & logic outputs logic output pin number logic #1 pin #1 logic #2 pin #6 logic #3 pin #8 pin #9 logic #4 pin #5 ground DRC 4+4 Pin #1 +12 Volts DC Power Supply - + 12V Relay Contacts Logic Output #1 1N4004 Diode Pin #5 normally closed common normally open Coil 7 CONFIGURATION All Configuration parameters are adjustable using the Windows 95 'PC Control Software' and serial cable provided with the DRC 4+4. The ® PC Control Software provides programs for various ADVANTAGE products, including the DRC 4+4. The DRC 4+4 program includes multiple control screens, which are described on the following pages. Once the software is started (and Comm Port Configuration is set), various screens are accessible through the drop-down menus at the top of the opening screen. Additional control screens are then available from the Configure DRC 4+4 menu. [. . . ] If the mixer or system does not provide input Patch jacks, the DRC 4+4s can be connected directly at the inputs using either `Y' cables at the In/Out jacks or 2-Conductor TS 1/4" Phone cables at both the In/Out & Patch jacks (see Rear Panel Features on page 3). This application also shows the two DRC 4+4s controlling eight lighting dimmers and a video camera, possibly for a theatrical production. The eight Control Voltage Outputs (plus ground) from the DRC 4+4s are connected to +10VDC analog lighting dimmers. The eight Logic Outputs from the DRC 4+4s are connected to control terminals on a video camera, which select Pan/Tilt & Zoom presets (see Logic Outputs on page 7). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP DRC 4 4




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP DRC 4 4 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.