Detailed instructions for use are in the User's Guide.
[. . . ] AudiaSOLO Digital Audio Platform
AudiaSOLO is a cost-effective, single rack-space version of Audia, ® the benchmark in digital audio systems for demanding professional sound installations. [. . . ] b uilt-indiagnostictools r emotefunctioncontrolviaEthernet m ulti-levelsecuritycoding RoHScomplianceandAESgroundingpractices C E markedandUL/C-ULlisted c overedbyBiampSystems'five-yearwarranty
·
A bilitytoselect, view, andcalibrate: ° Mixers:standard, automatic, matrix, combiners Equalizers:graphic, parametric, feedback ° Filters:HPF, LPF, highshelf, lowshelf, all-pass ° ° Crossovers:2-Way, 3-Way, 4-Way ° Dynamics:leveler, comp/limiter, ducker, ANC ° Routers:2x4~56x56 ° Delays:0~2000ms ° Controls:levels, presets, logic, events, etc. ° Meters:signalpresent, peak, RMS ° Generators:tone, pink-noise, white-noise Diagnostics:transferfunction °
ARCHITECTS & ENGINEERS SPECIFICATION
TheDigitalAudioPlatformshallbeavailableinthreehardwareconfigurations:8-in/8-out(8x8);12-in/4-out(12x4); and4-in/12-out(4x12). Inputsandoutputsshallbeanalog, withinternal24-bitA/D&D/Aconvertersoperatingata samplerateof48kHz. Allinternalprocessingshallbedigital(DSP). Electronicallybalancedinputsandoutputsshallbe providedonplug-inbarrier-stripconnectors. Inputsshallbeindividuallyprogrammabletoaccepteithermicrophoneor linelevelsignals. The12x4configurationshallallowinputs11&12tobesetformonosummingofunbalancedstereo linelevelsignals. Outputsshallnormallyprovidelinelevelsignals, however, the4x12configurationshallallowoutputs 1~4tobeindividuallyprogrammedtoprovidemicrophonelevelsignals. Each hardware configuration shall include six 60MHz 32-bit floating point DSPs. Software shall be provided for creating/connectingDSPsystemcomponentswithineachhardwareunit. Availablesystemcomponentsshallinclude (but not be limited to) various forms of: mixers, equalizers, filters, crossovers, dynamics/gain controls, routers, delays, remotecontrols, meters, generators, anddiagnostics. Ethernetcommunicationsshallbeutilizedforsoftware controlandconfiguration. Afterinitialprogramming, systemsmaybecontrolledusingeitherTCP/IPorRS-232serial communicationbythirdpartycontrolsystems(suchasAMX®andCrestron®), byPCcomputer, and/orbydedicated remotecontroldevices. SoftwareshalloperateonaPCcomputer, withnetworkcardinstalled, runningWindows®XP Professional/Vista. TheDigitalAudioPlatformshallbeCEmarked, UL/C-ULlisted, andshallincorporateAES48-2005 Grounding&EMCpractices. TheDigitalAudioPlatformshallbecompliantwithEUDirective2002/95/EC, theRoHS directive. Warrantyshallbe5years. [. . . ] DO NOT OPEN.
inputs
6
5
4
3
2
1
UL
R
52SJ
24VDC @ 1. 5A
hi lo
Ethernet link
L
R
L
R
AudiaSOLO BLOCK DIAGRAM
TCP/IP Control Comms Remote Control Bus
RS-232
MicroProcessor
Memory
Analog Inputs
A/D
DSP Cluster
D/A
Analog Outputs
BiampSystems, 10074S. W. ArcticDrive, Beaverton, Oregon97005U. S. A. (503)641-7287www. biamp. com
03Dec08 [. . . ]