User manual BIAMP 6702

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BIAMP 6702. We hope that this BIAMP 6702 user guide will be useful to you.


BIAMP 6702 : Download the complete user guide (389 Ko)

Manual abstract: user guide BIAMP 6702

Detailed instructions for use are in the User's Guide.

[. . . ] AudiaFUSION features an 8-channel modular amplifier, 16x16 I/O via CobraNet® and DSP with support for channelto-channel and device-to-device failover. [. . . ] AudiaFUSION can support up to 8 amplifier cards that are individually software configurable from 100-600 watts for up to 2400 watts of power, with softwareselectable 70V, 100V and low impedance outputs per card. Intuitive software provides audio system design via PC and allows easy selection, viewing and calibration of numerous audio components: mixers, combiners, matrixes, equalizers, filters, crossovers, dynamics, routers, delays, meters, generators, diagnostic tools, and more. Once a system design is compiled, it is downloaded into AudiaFUSION, where it can be controlled via AMX®, Crestron®, other third-party control system, or via computer running daVinciTM control software. When installed in a system together, AudiaFLEX and AudiaFUSION processing resources are allocated as needed, making the whole system more efficient. FEATURES · Modular based design · Amplification modules have software configurable power levels/load options ­ 8 amplification modules per frame with 100 to 600 Watts per module (maximum of 2400W per chassis) ­ 70V or 100V with direct drive capability, or low-impedance (4 or 8) operation ­ Maximum of 2400 Watts of power in 3 rack spaces · TCP/IP Network controllable · LED Indication: ­ Signal present ­ Peak present ­ Clip present ­ Heat sink temperature fault ­ Amplifier failure ­ Fan stuck-rotor · Internal amplifier module failover mode · Entire device failover mode · Software Monitoring Features: ­ Peak present ­ Heatsink temperature value, warning and fault ­ Short circuit on output ­ Amplifier failure ­ Impedance min/max threshold warning ­ Excessive clipping ­ Fan stuck-rotor · Seamless integration with CobraNet-enabled Audia systems · CobraNet Interface (16 channels in/16 channels out) · CobraNet latency 5-1/3, 2-2/3 or 1-1/3 ms, software configurable · Dual CobraNet ports for redundancy · Selectable 115/230 volt operation · Control via RED-1, daVinci or third party control systems · CE marked, UL listed & RoHS compliant · Covered by Biamp Systems' warranty ARCHITECTS & ENGINEERS SPECIFICATION The modular amplifier shall be designed exclusively for use with Biamp® Audia® systems. The amplifier shall be CE marked, UL listed and shall be compliant with the RoHS directive. (503) 641-7287 www. biamp. com AudiaFUSION SPECIFICATIONS Inputs: 20 bits, 48 kHz, supported CobraNet latency 5-1/3, 2-2/3 or 1-1/3 ms software configurable Power: Overall Dimensions: Height: Width: Depth: Weight: Chassis: AM-600 card: 110~120 & 220~240 VAC switch selectable, 50/60Hz 5. 25 inches (133mm) 19 inches (483mm) 17. 25 inches (438mm) 50 lbs. (0. 57 kg) Outputs: Supported Loads: Continuous Operation1: Frequency response: Signal-to-Noise Ratio (unweighted, 22 Hz ­ 22 kHz): 100W ­ 600W THD + N: Intermodulation distortion (SMPTE): Inter-channel Isolation: DC offset: Connection: 4 or 8 or 70-Volt Line, or 100-Volt line direct drive 1 kHz continuous sine wave indefinitely 20 Hz ­ 20 kHz (+/- 1dB) 4 Ohm >95dB 8 Ohm 70V 100V >95dB >100dB >101dB 0. 3% (20 Hz - 20kHz) all loads & power levels <0. 2% >-75dB (20Hz - 2-kHz, full power out) <10 mV RJ45 with shielded Ethernet cable (CAT5, CAT5e, CAT6, or CAT7) Environment: Ambient Operating Temperature Range: Ambient intake humidity: Altitude: 32-95 degrees F (0 ­ 35° C) 0 ­ 100% non-condensing 0 ­ 10, 000 Feet MSL Compliance: EU Directive 2002/95/EC, RoHS directive UL listed, CE marked AudiaFUSION BACk PANEL 10 9 8 BIAMP SYSTEMS MODEL AudiaFUSION 110-120/220-240V~ 115V 50/60Hz 2400WATT CAUTION RISK OF ELECTRICAL SHOCK. In chassis with fans running normally and unrestricted intake and exhaust 7 6 5 4 3 2 1 SERIAL CONTROL PORT Class 2 Wiring 1234 Logic I/O AM-600 AM-600 AM-600 AM-600 AM-600 AM-600 AM-600 FUSE FUSE Primary 220-240V: T 12 H, 250V 110-120V: T 20 H, 250V CobraNet® Connections Only YEL: In use/Conductor GRN: Link/Activity NM-1 OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT 52SJ AudiaFUSION BLOCk DIAgrAM Biamp Systems, 10074 S. W. [. . . ] In chassis with fans running normally and unrestricted intake and exhaust 7 6 5 4 3 2 1 SERIAL CONTROL PORT Class 2 Wiring 1234 Logic I/O AM-600 AM-600 AM-600 AM-600 AM-600 AM-600 AM-600 FUSE FUSE Primary 220-240V: T 12 H, 250V 110-120V: T 20 H, 250V CobraNet® Connections Only YEL: In use/Conductor GRN: Link/Activity NM-1 OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT 52SJ AudiaFUSION BLOCk DIAgrAM Biamp Systems, 10074 S. W. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP 6702




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP 6702 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.