User manual BERTAZZONI X366GGVX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BERTAZZONI X366GGVX. We hope that this BERTAZZONI X366GGVX user guide will be useful to you.


BERTAZZONI X366GGVX : Download the complete user guide (2247 Ko)

You may also download the following manuals related to this product:

   BERTAZZONI X366GGVX (2863 ko)

Manual abstract: user guide BERTAZZONI X366GGVX

Detailed instructions for use are in the User's Guide.

[. . . ] Installation, Service and User Instructions FREESTANDING GAS RANGES BERTAZZONI DIMENSIONS: 36'' (915 mm)(W) x 253/16'' (640 mm)(D) x36'' (915 mm)(H) Models X365GGVX (X36 5 00 X) [M3W0GTU4X(2 or 5)A] Models X366GGVX (X36 6 00 X) [M3Y0GTU4X(2 or 5)A] IMPORTANT - PLEASE READ AND FOLLOW -Before beginning installation, please read these instructions completely and carefully. -Do not remove permanently affixed labels, warnings, or plates from the product. -The installer should leave these instructions with the consumer who should retain for local inspector's use and for future reference. Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code ANSIZ223. 1-latest edition. [. . . ] All stainless steel body parts should be wiped with hot, soapy water and with a liquid cleaner recommended for use with stainless steel If buildup occurs, do not use steel wool, abrasive cloths, cleaners, or powders!If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wood or nylon scraper. Do not use a metal knife, spatula, or any other metal tool to scrape stainless steel!NOTE: These installation instructions should remain with the unit for future reference. The electrical diagram is located in the backside or the appliance. REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on the appliance. Replacement parts are available from factory authorized parts distributors. Conversion to different types of gas Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply. For Natural Gas fit regulator assembly described in Fig. Adaptation of the pressure regulator for use with different type of gas The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with Natural Gas at a nominal outlet pressure of 4" w. c. and it is pre-arranged from the factory to operate with one of these gas/pressure as indicated in the labels affixed on the appliance, package and Instruction booklet. To convert the regulator for use with other types of gas follow these instructions: 1) Unscrew by hand the upper metal stopper of the regulator. 2) Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper, afterward screw it again in opposite way under the metal stopper (for gas reference see the written "LP" and "NAT" with relative indicating arrows on the white piece). 3) Screw again by hand the metal stopper in the original position on the regulator. Following these exact instructions the gas regulator is converted for use with the other gas/pressure. 9 - CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: To change the nozzles of the burners use the following procedure: Lift up the burners and unscrew the nozzles ( Fig. ) using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE shown below. Follow the instructions below to change the oven burner nozzle: 1) Remove the oven level (Fig. 2) Loosen the screw V and pull out the burner from the support being careful not to damage the ignition plug and the thermocouple (Fig. 10-11) using a 10 mm spanner and replace it with the nozzle needed for the new type of gas according to what is indicated in TABLE shown below. Follow the instructions below to change the broiler burner nozzle: 1) Loosen the screw and pull out the burner from the support being careful not to damage the ignition plug and the thermocouple (Fig. 12) using a 7 mm spanner and replace it with the nozzle needed for the new type of gas according to what is indicated in TABLE shown below. 10 Models X366GGVX (X36 6 00 X) [M3Y0GTU4X(2 or 5)A] Adapting to different types of gas Burner Auxiliary Semi-Rapid Rapid Position Front R Rear L & C Front C Rear L Front L Inner Dual Burner Front L Outer Oven Broiler Oven downside Oven upside Injector diam. [mm. ] 0, 90 0, 54 1, 18 0, 70 1, 55 0, 92 0, 80 0, 49 N°2 x 1, 15 N°2 x 0, 70 2, 00 1, 15 1, 90 1, 10 Gas Type NG LP (Propane) NG LP (Propane) NG LP (Propane) NG LP (Propane) NG LP (Propane) NG LP (Propane) NG LP (Propane) Pressure [i. w. c. ] 4" 11" 4" 11" 4" 11" 4" 11" 4" 11" 4" 11" 4" 11" Max Rate [BTU/h] [W] 3400 996 3400 996 6100 1787 6100 1787 10400 3047 10400 3047 2800 820 2800 820 12000 3516 12000 3516 16000 4688 16000 4688 14500 4248 14500 4248 Min Rate [BTU/h] [W] 900 264 900 264 1500 439 1500 439 2500 732 2500 732 900 264 900 264 4500 1318 4500 1318 4000 1172 4000 1172 Only Max Only Max Only Max Only Max By-pass diam. [mm] Regulated 0, 29 Regulated 0, 36 Regulated 0, 47 Regulated 0, 29 Regulated 0, 65 Regulated 0, 60 No by-pass No by-pass Models X365GGVX (X36 5 00 X) Adapting to different types of gas Burner Auxiliary Semi-Rapid Rapid Position Front R Rear L and R Rear L Centre Inner Dual Burner Centre Outer Oven Broiler Oven downside Oven upside Injector diam. [mm. ] 0, 90 0, 54 1, 18 0, 70 1, 55 0, 92 0, 80 0, 49 N°2 x 1, 15 N°2 x 0, 70 2, 00 1, 15 1, 90 1, 10 Gas Type NG LP (Propane) NG LP (Propane) NG LP (Propane) NG LP (Propane) NG LP (Propane) NG LP (Propane) NG LP (Propane) [M3W0GTU4X(2 or 5)A] Max Rate [BTU/h] [W] 3400 996 3400 996 6100 1787 6100 1787 10400 3047 10400 3047 2800 820 2800 820 12000 3516 12000 3516 16000 4688 16000 4688 14500 4248 14500 4248 Min Rate [BTU/h] [W] 900 264 900 264 1500 439 1500 439 2500 732 2500 732 900 264 900 264 4500 1318 4500 1318 4000 1172 4000 1172 Only Max Only Max Only Max Only Max By-pass diam. [mm] Regulated 0, 29 Regulated 0, 36 Regulated 0, 47 Regulated 0, 29 Regulated 0, 65 Regulated 0, 60 No by-pass No by-pass Pressure [i. w. c. ] 4" 11" 4" 11" 4" 11" 4" 11" 4" 11" 4" 11" 4" 11" CAUTION: save the orifices removed from the appliance for future use REGULATION OF BURNERS Primary air adjustment: Oven burner adjustment: follow the instructions below to adjust the primary air for the over burner: 1) Remove the oven bottom. 2) Loosen the screw P and adjust the position X of the Venturi cone (Fig. Broiler burner adjustment: to adjust the broiler burner loosen screw P and adjust the position X of the Venturi cone (Fig. 14) according to the measurements indicated in table 4. TABLE N°4: Burner primary air regulation (indicative) Type of gas NG (Natural Gas) LP (Propane Gas) Burner Oven Broiler Inches (mm) Inches (mm) 9/16 (15) fully open fully open fully open 11 Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum: 1) Light the burner and set the knob to the MINIMUM position (small flame). [. . . ] Wait about 10 seconds after the burner has been completely lit and then release the knob. ATTENTION: To use broiler please utilize the proper broiler grid installed inside the grid enamelled tray supplied with the appliance; broiler tray shall be supported by oven grid. WARNING: As with the oven, the broiler must be lit with the door completely open. The gas broiler operation is indicated by a blue light IMPORTANT: when broiling food keep the door closed. . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BERTAZZONI X366GGVX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BERTAZZONI X366GGVX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.