User manual BERTAZZONI A365GGVXT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BERTAZZONI A365GGVXT. We hope that this BERTAZZONI A365GGVXT user guide will be useful to you.


BERTAZZONI A365GGVXT : Download the complete user guide (4004 Ko)

Manual abstract: user guide BERTAZZONI A365GGVXT

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION, USE & CARE MANUAL FREESTANDING GAS RANGES Models A365GGVXE A365GGVXT [M3W0GNU4X(2, 5)AUG] [M3W0GNU4X(2, 5)AUA] 310445 1 From the desk of the President Dear new owner of a Bertazzoni product, I want to thank you for choosing one of our beautiful PRO ranges. We know that you have many brands and products to choose from and we are thrilled that you have decided to take onw of your products into your home. We take as much pride in making our ranges as we hope you will in owning them. Each of our products is a blend of Italian design finess and superior appliance technology. [. . . ] This would typically result in the bottom of the hood being 61 1/2" (156. 2 cm) to 67 1/2" (171. 5 cm) above the floor. These measurements provide for safe and efficient operation of the hood. Before installation of the exhaust hood, consult local or regional building and installation codes for additional specific clearance requirements. Refer to the range hood installation instructions provided by the manufacturer for additional information. A B C D E F 36" (91, 5 cm) 36" (91, 5 cm) 13" (33, 0 cm) 18" (45, 7 cm) 35"1/2(90, 2 cm) / 37" ¼ (94, 6 cm) 6" (15, 2 cm) 12 ELECTRICAL CONNECTION This unit is manufactured for a polarized, grounded 120 volt/60 Hz, 16 amp system. The minimum of 102 VAC is required for proper operation of gas ignition systems. In case of replacement, the power cord shall be replaced with one of the same type, size and length. ELECTRICAL GROUNDING This appliance is equipped with a threeprong plug for your protection against shock hazard and should be plugged directly into a properly grounded socket. ELECTRICAL SHOCK HAZARD Disconnect electrical power at the circuit breaker box or fuse box before installing the appliance. Failure to follow these instructions could result in serious injury or death CAUTION Label all wires prior to disconnecting when servicing controls. Verify proper operation after servicing. WIRING DIAGRAM 13 GAS CONNECTION All gas connections must comply with national and local codes. The gas supply line (service) must be the same size or greater than the inlet line of the appliance. This range uses a 1/2" NPT inlet (see drawing below for details of gas connection). For LP/propane household installation, the appliance must be converted by the dealer, by a factorytrained professional or by a qualified licensed plumber or gas service company. Gas conversion is important for safe and effective use of the appliance. It is the responsibility of the dealer and the owner of the range to perform the appropriate gas conversion following the directions of the manufacturer. THE GAS CONVERSION PROCEDURE IS DESCRIBED IN THIS MANUAL AND IN THE PACKAGE CONTAINING THE CONVERSION NOZZLES SHIPPED WITH EVERY RANGE. Please provide the service person with this manual before work is started on the range. MANUAL SHUTOFF VALVE THIS VALVE IS NOT SHIPPED WITH THE APPLIANC AND MUST BE SUPPLIED BY THE INSTALLER. The manual shutoff valve must be installed in the gas service line between the gas hookup on the wall and the appliance inlet, in a position where it can be reached quickly in the event of an emergency. In Massachusetts: A 'T' handle type manual gas valve must be installed in the gas supply line to this appliance. FLEXIBLE CONNECTIONS In case of installation with flexible couplings and/or quickdisconnect fittings, the installer must use a heavyduty, AGA designcertified commercial flexible connector of at least 1/2" (1. 3 cm) ID NPT (with suitable strain reliefs) in compliance with ANSI Z21. 41 and Z21. 69 standards. In Massachusetts: The unit must be installed with a 36" (3foot) long flexible gas connector. In Canada: use CAN 16. 1088 metal connectors for gas appliances and CAN 16. 9 M79 quick disconnect device for use with gas fuel. PRESSURE TESTPOINT STOPPER VALVE WARNING!Leak testing of the appliance shall be conducted according to the manufacturer's instructions. [. . . ] And relase it, the automatic ignition system will automatically generate the spark for 5 seconds and will engage the termocouple. Then check that the broiler burner flame is and remain correctly lit, and clese the door. Do not press the broiler knob for more than 2, 5 sec. otherwise automatic ignition system lock itself and it will be necessary to retry the whole ignition sequence; if the broiler burner do not remain correctly lit at the first attempt, open 29 MAINTAINING YOUR RANGE REPLACING THE OVEN LIGHT BULB CLEANING YOUR RANGE ATTENTION!Cleaning after installation: use a stainless steel cleaning product or wipe to eliminate the glue residues of the blue protection film after removal. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BERTAZZONI A365GGVXT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BERTAZZONI A365GGVXT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.