User manual BENTEL SECURITY J408 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BENTEL SECURITY J408. We hope that this BENTEL SECURITY J408 user guide will be useful to you.


BENTEL SECURITY J408 INSTALLATION: Download the complete user guide (2581 Ko)

Manual abstract: user guide BENTEL SECURITY J408INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] CONVENTIONAL F I R E PA N E L S 424 408 INSTALLATION MANUAL ® This Control panel can be programmed using the respective Software J400 release 1. 0 or higher. BENTEL SECURITYsrl shall not assume the responsibility for damage arising from improper application or use. This Control panel has been designed and manufactured to the highest standards of quality and performance. Installation of this Control panel must be carried out strictly in accordance with the instructions described in this manual, and in compliance with the local laws and bylaws in force The J424 and J408 Control panels comply with the essential requirements of standards EN54-2; EN54-4. [. . . ] The Pre-extinguishment Phase will re-start from the point of interruption. If you disable the Extinguishment Module during the Extinguishment Phase, the latter will be interrupted. button This button will allow you to Disable/Enable manual activation of the Extinguishment Module. button can be used during This operation will be signalled by: Ø the Disable Manual Extinguish. LED (On). USER'S INSTRUCTIONS 5 24R OUT FAULT 24R OUT RESTORE 24V OUT FAULT 24V OUT RESTORE ALARM ZONE AUTO UNBYPASSED BATT. CHARG. FAULT BATT. CHARG. REST. BATTERY RESTORE BATTERY RESTORE BATTERY RESTORE BUZZER SILENCED BYPASSED ZONE DETECTOR MISSING DIALLER ACTIVATE DISAB. AUTO DL OUT FAULT DL OUT RESTORE DL OUTPUT EM ACTIVATED EM INPUT FAULT EM INPUT RESTORE EV OUT ACTIVATED EV OUT FAULT EV OUT RESTORE EVACUATE GND FAULT REST. GROUND FAULT IE ACTIVATED IE INPUT FAULT IE INPUT RESTORE INVESTIGATION MAIN FAULT MAIN RESTORE MANUAL BYPASSED MANUAL UNBYPASS. MODE NAC OUTPUT NAC1 FAULT NAC1 RESTORE NAC2 FAULT NAC2 RESTORE OUT 1 RESTORE OUT 1 SHORT OUT 2 RESTORE OUT 2 SHORT OUTS BYPASSED OUTS UNBYPASSED PE OUT ACTIVATED PE OUT FAULT PERIPHERAL FAULT PERIPHERAL REST. Device type+Number DESCRIPTION 24R output shorted 24R output previously shorted 24V output shorted 24V output previously shorted Zone no. disconnected Panel batteries empty, malfunctioning or disconnected Batteries of Power Supply Stat. nr previously low Panel batteries previously empty, malfunctioning or disconnected Batteries of Power Supply Stat. is missing Dialler Output active Automatic Extinguishment of Extinguishment Mod. nr. i disabled Dialler connections interrupted or shorted Dialler connections interrupted or shorted The Dialler Output has been disabled/enabled EM Input of Extinguishment Mod. previously shorted or open Evacuation command executed Control panel ground fault restored Control panel leakage to Earth IE Input of Extinguishment Mod. previously shorted or open Investigation Done Mains failure to Control panel/Power Supply Stat. nr re-enabled Control panel switched from Night to Day Mode One of the Alarm outputs has been disabled/enabled Alarm device connections interrupted or shorted Alarm device connections interrupted or shorted Alarm device connections interrupted or shorted Alarm device connections interrupted or shorted O1 Output of Power Supply Stat. shorted or open The device concerned missing or faulty PR Output of Extinguish. previously shorted or open The device concerned previously missing or faulty Table 2 Event Descriptions (Continues . . . ): AV = Extinguishment Done; EM = Manual Extinguishment; EV = Electrovalve; IE = Inhibit Extinguishment ; PR = Pre-extinguishment; PS = Pressure switch. 6 Conventional Fire Panels J424/J408 PS ACTIVATED PS INPUT FAULT PS INPUT RESTORE RESET RESTORE SILENCED SWITCH. DISCONN. ZONE OPEN ZONE PREALARM ZONE SHORT EVENTS DETAILS Extinguishment Mod. previously shorted or open Reset Done One of the zone detectors previously missing Silence Done Switching Power Supply of Station nr. shorted Table 2 Event Descriptions: AV = Extinguishment Done; EM = Manual Extinguishment; EV = Electrovalve; IE = Inhibit Extinguishment ; PR = Pre-extinguishment; PS = Pressure switch. Logger The Control panel logger can store the Time, Date and Details of 50 events. From standby status, press Ú or Ù to view the LOGGER: LED description The actions that must be carried out when the control panel LED's go from standby status into alarm status are explained, for each LED, following: when in standby status only the GREEN Mains LED should be lit. [. . . ] Using the Zone keys (Z1 to Z 8 for the J408; Z1 to Z 24 for the J424) ENABLE/DISABLE the respective Zones for "Activation" of the Extinguishment Module concerned: ­ if the respective Zone LED is On, the Zone will trigger activation of the Extinguishment Module concerned; ­ if the respective Zone LED is Off, the Zone will NOT trigger activation of the Extinguishment Module concerned. n Zones Descriptions 1. Using Ú or Ù, select Zones Descriptions: ZONE DESCRIPTION press ENTER 2. Using Ø or ×, select the character you want to change (the selected character will blink). Using Ú or Ù, select the new character. ZONE 1 Warehouse 4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BENTEL SECURITY J408




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BENTEL SECURITY J408 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.