User manual BENSHAW SURPROTEX SPD

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BENSHAW SURPROTEX SPD. We hope that this BENSHAW SURPROTEX SPD user guide will be useful to you.


BENSHAW SURPROTEX SPD : Download the complete user guide (145 Ko)

Manual abstract: user guide BENSHAW SURPROTEX SPD

Detailed instructions for use are in the User's Guide.

[. . . ] 5 Run each phase of the load power wire through the corresponding "tunnel". Display Mounting: The display unit may be mounted on top of the SPD relay, or mounted on the exterior of a control panel with the optional panel mounting kits (SPD-M1~4). The panel mounting kit is available with 3 lengths of connecting cable. SPD-M1 = 1 meter cable SPD-M2 = 2 Meter cable SPD-M4 = 4 meter cable Programming: Programming of menu items can only occur with the relay in the trip mode (except Motor FLA and O/L class). Refer to chart on page 6. 1 2 3 4 5 6 7 8 Menu Parameters: Menu Item 1. [. . . ] This sets the length of time that the ground fault current determined by the dip switches behind the display must be detected before the SPD will trip. Values: SPD-XXS-X: Off/60-110 (% of thermal capacity) in 10% steps SPD-XXSZ-X: Off/0. 05, 0. 1-1. 0 seconds in 0. 1 second steps Default: The default value in both cases is Off Parameter Descriptions: 8. Ct: Description: This parameter tells the SPD the ratio of the current transformer connected to it, with the secondary normalized to 1A. Values: 1, 5-120 in steps of 5 Default: The default value is 1 for SPD-06XX-X and 10 for SPD-60XX-X 9. P-F: Description: This parameter activates the Phase Failure detection for the SPD. If current is lost in one or two phases for more than 3 seconds the SPD will trip. Off/On Values: The default value for this parameter is On Default: Time Dial: Description: This dial sets the overload class of the SPD. The SPD uses an I^2T curve that, at 600%, will trip in the time set by this dial. 0-63 in steps of 1 Values: The default value is 0 Default: Terminals: Description: A1-A2: 120 VAC 60 Hz control power 95-96: N/C Trip contact (Opens at 100% thermal capacity) 97-98: N/O Trip contact (Closes at 100% thermal capacity) 07-08: SPD-XXS-X:N/O Alarm contact (Changes state at Alt% setting) SPD-XXSZ-X: Zero sequence CT input DISCONNECT DEVICE AC120V TR OFF (RESET) MC X1 X2 AC120V MC FUSE FUSE TR OFF (RESET) MC ON OL GF RUN STOP TRIP TRIP 2. dEF: A1 A2 95 97 07 AX1 MC ON SPD OL GR AX2 96 98 08 MC GROUND FAULT CT Description: This parameter sets the length of time the SPD will ignore current flow after a start is given if parameter 1 is set to dEF. Values: 00-30 seconds in 2 second steps The default value is 00 seconds Default: A1 96 97 98 07 08 A2 95 97 07 Parameter Descriptions: AL 3. StL: Description: This parameter activates the Stalled Motor detection. When activated and the load draws 180% of the Current Dial setting for 5 seconds after a start, the SPD will trip. Values: Off/On Default: The default value for this parameter is Off SPD 96 98 08 2 NO - Closes on all faults except control power failure 1 NC - Opens on all faults (open when no control power applied) Current Dial: Description: This dial sets the Full Load Amps (FLA) for the SPD. This dial should be set at (Motor FLA x Motor Service factor)/CT ratio. Values: 0. 5-6. 3 Amps in 0. 1 Amp steps for SPD-06XX-X, 5. 0-63 Amps in 1 Amp steps for SPD-60XX-X Default: The default value is 0. 5 for SPD-06XX-X, and 5. 0 for SPD-60XX-X Sto: Description: This must be selected to save changes to parameter, otherwise changes will be aborted when TEST mode is exited. Und: Description: This parameter sets the Undercurrent protection for the SPD. If the load current falls below this level for 3 seconds, the SPD will trip. Off/30-70 (% of Current Dial setting) in 10% Values: steps The default value is Off Default: 10 7. Loc: Description: This parameter sets up the Locked Rotor protection for the SPD. If the load draws this percentage of the Current Dial setting for 0. 5 seconds, the SPD will trip. Values: Off/200-900 (% of Current Dial setting) in 100% steps Default: The default value for this parameter is Off 11 8 12 Trip Indication: Protection Function Thermal O/L UnderCurrent Reverse Phase Phase Failure Phase Unbalan. [. . . ] Values: 1, 5-120 in steps of 5 Default: The default value is 1 for SPD-06XX-X and 10 for SPD-60XX-X 9. P-F: Description: This parameter activates the Phase Failure detection for the SPD. If current is lost in one or two phases for more than 3 seconds the SPD will trip. Values: Off/On The default value for this parameter is On Default: Time Dial: Description: This dial sets the overload class of the SPD. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW SURPROTEX SPD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BENSHAW SURPROTEX SPD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.