User manual BENSHAW RSM SYNCHRONOUS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BENSHAW RSM SYNCHRONOUS. We hope that this BENSHAW RSM SYNCHRONOUS user guide will be useful to you.


BENSHAW RSM SYNCHRONOUS : Download the complete user guide (1086 Ko)

Manual abstract: user guide BENSHAW RSM SYNCHRONOUS

Detailed instructions for use are in the User's Guide.

[. . . ] BENSHAW REDISTART MICRO II SYNCHRONOUS STARTER INSTRUCTION MANUAL RSM6/6B/7/7B SERIES Solid State Motor Control Technology Publication #: 890015-04-02 The Leader In TABLE OF CONTENTS Table of Contents 1. Computer Card JC11 Header Assignments RediStart Micro II Power Card Jumpers . 44 45 46 46 47 47 47 47 48 48 48 49 49 5. 2 PROGRAMMING: Quick Start . 52 52 52 53 53 ii TABLE OF CONTENTS 5. 6 PROGRAMMING: Starter Setup - Forward2 Profile . [. . . ] The TruTorque deceleration time parameter is adjustable from 0 to 100 seconds in 1 second intervals. The default TruTorque deceleration time is 0 seconds. Values Default TT DCL Tor (ending deceleration torque) Description The value sets the final torque level for the Trutorque deceleration ramp. If the motor is coming to a stop too quickly or if the starter continues to apply current to the motor after the motor has stopped this parameter can be increased in 5% increments. If the motor is still rotating when the desired deceleration time has expired, decrease this parameter by 5% and retest. Values Default The TruTorque deceleration ending torque value can be set from 1% to 100% torque in 1% steps. The default TruTorque deceleration ending torque setting is 10% 57 5. 8 PROGRAMMING: Starter Setup - TruTorque Ramp Int Torque (initial torque) Description The initial torque parameter sets the initial torque level that the motor will produce during starting. This parameter should be set to a level that allows the motor to begin acceleration with a few seconds of a start command being received. The default value for initial torque is 20%. Values Default Max Torque (maximum torque) Description The maximum torque parameter sets the final level of torque that is supplied to the motor during starting. For a loaded motor, the maximum torque parameter initially should be set to 100% or greater. If the maximum torque value is set too low, the motor may not produce enough torque to reach full speed (UTS). On a lightly loaded motor this parameter may be reduced below 100% to provide for smoother starts. The default value for the maximum torque parameter is 105%. Values Default Ramp Time Description The ramp time parameter sets the time it takes for the commanded torque to go from the Initial Torque Setting to the Maximum Torque Setting. If the ramp time expires before the motor reaches full speed the starter will maintain the set Maximum Torque level until either the motor reaches full speed, the stall (UTS) timer expires, or the motor thermal overload trips. It is not the same ramp time parameter that is used for current ramp profile starts. Note: Setting the ramp time to a specific value does not necessarily mean that the motor will take this time to accelerate to full speed. The motor and load may achieve full speed before the ramp time expires if the application does not require the set ramp time and maximum torque to reach full speed. Alternatively, the motor and load may take longer than the set ramp time to achieve full speed. Values Default The TruTorque ramp time is adjustable from 0 to 120 seconds in 1 second intervals. The default value for the TruTorque ramp time is 15 seconds. 58 5. 8 PROGRAMMING: Starter Setup - TruTorque Ramp TT Over Cu (TruTorque overcurrent trip) Description The TruTorque overcurrent trip parameter is set as a percentage of FLA. If the motor current remains above this level for longer than the delay time the starter will trip. In order to protect applications such as pumps from water hammer when a fault does occur a normal deceleration profile will occur to "gracefully" shut down the system before the TruTorque Overcurrent Fault is displayed and the starter is disabled. Note: The TruTorque Overcurrent Trip only operates during TruTorque ramping before the starter has indicated an up-to-speed condition. [. . . ] Each line lists the parameter, page reference, blank, and default setting. The blank spot is for entering the programmed value so that a record of the entered parameters is kept. NOTE: Not all starters have all of the listed parameters. Recording Parameters Quick Start Parameter Quick Start Motor FLA Serv. Ramp Time Overload Phase Orde Page 47 47 47 47 48 48 48 49 49 Range 1-1200 1. 00-1. 99 Curr, TT Coas, VDCL, TT 50-400 100-600 0-120 see text INS, ABC, CBA Step 1 0. 01 1 1 1 1 Unit Amps % % % sec. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW RSM SYNCHRONOUS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BENSHAW RSM SYNCHRONOUS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.