User manual BENSHAW RS7

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BENSHAW RS7. We hope that this BENSHAW RS7 user guide will be useful to you.


BENSHAW RS7 : Download the complete user guide (1112 Ko)

Manual abstract: user guide BENSHAW RS7

Detailed instructions for use are in the User's Guide.

[. . . ] 57 57 57 57 58 58 59 59 60 60 60 61 61 61 61 62 62 63 63 63 63 64 65 65 65 66 66 5. 7 PROGRAMMING: Starter Setup - Jog Cntrl Setup . 71 iii TABLE OF CONTENTS 5. 15 PROGRAMMING: Motor Protection - Line Current . % No C@Run (percent no current at run) No C@R Dly (no current at run delay) . 85 86 86 86 iv TABLE OF CONTENTS 5. 28 PROGRAMMING: Meters & Relays - Standard Relays . [. . . ] When a motor is operating in the jog at set speed mode, its cooling capability is greatly reduced. Therefore, the running time of the motor is dependant on the motor current. If the jog at set speed will be used on a regular basis, the motor temperature should be monitored using a thermostat. The thermostat can be connected between the power and input terminal 1 of the JC13 terminal block on the RediStart Micro II computer card so that the starter will trip when a fault occurs. Alternatively, temperature monitoring devices, such as thermistors or RTDs can be used. This will prevent the motor from being overheated and inadvertently damaged. Due to the way the jog at set speed operates, the starter may require the installation of a 5% line reactor to eliminate harmonic problems being introduced into the power system. This is dependent on the size of the motor in relation to the capacity of the power system. Values Default The jog current is adjustable from 25% to 250% in 1% increments. Time (maximum time) Description The maximum time parameter sets the time limit for continuous operation in the jog at set speed mode. This parameter should be set to a value that doesn't allow the motor to be operated in the jog at set speed mode for such a length of time that damage to the motor can occur. The default value for the Stab Cnst parameter is 100%. Ramp#1 Tim Description The Ramp#1 Tim parameter sets the length of time that the D. C. The Ramp#1 Tim is adjustable from 0 to 120 seconds in 1 second intervals. The default value for the Ramp#1 Tim is 15 seconds. Values Default Ramp#2 Tim Description The Ramp#2 Tim parameter sets the length of time that the D. C. The Ramp#2 Tim is adjustable from 0 to 120 seconds in 1 second intervals. The default value for the Ramp#2 Tim is 15 seconds. Values Default 61 5. 8 PROGRAMMING: Starter Setup - Tachometer Setup TLoss Dela (Tachometer Signal Loss Delay) Description The TLoss Delay time is the allowable time the starter will operate when a tachometer signal is lost. If the signal is lost, the starter will perform the action set by the TLoss Mode parameter. NOTE: Nuisance tachometer loss faults at start can be prevented by setting the initial current parameter to a value that allows the motor to begin rotating soon after a start is commanded. Values Default The TLoss Delay time parameter is adjustable from 0. 1 seconds to 90. 0 seconds in 0. 1 second intervals. The default value for the TLoss Delay time is 1. 5 seconds. TLoss Mode (Tachometer Signal Loss Mode) Description The TLoss Mode determines the starter's action if it has been detected the tachometer signal is lost. NOTE: If Current ramp or TruTorque ramp is selected, all values within these ramp profiles must be set for proper operation. NOTE: If Current ramp or TruTorque ramp is selected, and the tachometer signal is lost, the starter will shut down and automatically restart with the new starting mode. [. . . ] ONLY) TBP2 START/STOP 1 2 3 4 5 1 2 3 4 5 6 7 8 9 K1 - RUN RELAY K1 K2 - LOCAL START RELAY K3 - LOCAL STOP RELAY 1 2 TBP8 SCR GATE 4 TBP9 SCR GATE 2 K4 - GENERAL FAULT RELAY (SHOWN IN FAULTED STATE) 1 2 TBP3 RELAY OUTPUTS K5 - PROGRAMMABLE RELAY #1 K4 - PROGRAMMABLE RELAY #2 LEDP2 SCR STATUS (LOW VOLT. ONLY) 1 2 TBP10 SCR GATE 5 1 JP1 COMPUTER CARD RIBBON CABLE 2 1 TBP11 SCR GATE 3 LEDP3 SCR STATUS (LOW VOLT. ONLY) 1 2 3 4 5 6 7 8 1 2 SW1 SW2 (RIGHT - ON) TBP12 SCR GATE 6 TBP4 CURRENT TRANSFORMERS 1 2 3 TBP13 TACH. INPUT 120 7. 1 DRAWINGS RediStart Micro II Four (4) Relay Card Layout TB2 RELAY OUTPUTS 1 24 TB1 CARD POWER 1 2 J1 RIBBON CABLE CONNECTOR RediStart Micro II Seven (7) Relay Card Layout K1 Relay 1 2 3 K2 Relay 4 5 6 K3 Relay 7 8 9 K4 Relay 10 11 12 K5 Relay 13 14 15 K6 Relay 16 17 18 K7 Relay 19 20 21 K1 K2 K3 K4 K5 K6 K7 HOT 1 2 3 4 NEUTRAL TB3 120Vac Connector FU1 J1 J1 Ribbon Cable Connector 121 7. 1 DRAWINGS RediStart Micro II RS-232 Communications Card Layout RECEIVE LED TRANSMIT LED RIBBON CABLE CONNECTOR TO COMPUTER CARD LED1 RXD LED2 TXD RS-232 IC RS232 CARD J2 TB1 9-PIN SUB-D MALE DCE PINOUT RS-232 CONNECTORS TXD C COM RXD RediStart Micro II RS-485 Communications Card Layout RECEIVE LED TRANSMIT LED DRIVER ENABLE RIBBON CABLE CONNECTOR TO COMPUTER CARD LED1 RXD LED3 DE LED2 TXD RS485 CARD RS-485 IC TB1 J3 B(+) COM A(-) RS-485 CONNECTORS 9-PIN SUB-D FEMALE 122 7. 1 DRAWINGS RediStart Micro II RS-232/485 Communications Card Layout RIBBON CABLE CONNECTOR TO COMPUTER CARD TRANSMIT LED RECEIVE LED 120 OHM TERM SHIELD TO COM RS-485 CONFIGURATION SWITCHES RS-485 TERMINAL BLOCK RS-232 CONNECTOR 9 PIN, SUB-D, FEMALE DCE PINOUT RediStart Micro II Reversing/Braking Card Layout TB3 SCR GATE 1A TB4 SCR GATE 4A TB5 SCR GATE 3A TB6 SCR GATE 6A TB7 SCR GATE 7/11 1 2 G4A 1 2 TB4 K4A G6A 1 2 1 2 K1A K3A TB6 K6A TB3 G1A TB5 G3A TB7 G7A 1 2 K7 COM TB2 GATE POWER 21 +24VDC TB2 G4A G1A G6A G3A G7/11 TB1 TB1 GATE SIGNALS 123 7. 1 DRAWINGS Modbus Master Card (for Remote RTD Module) 24VDC FROM POWER CARD Gnd+24V 24VDC POWER SUPPLY Com +24V J8 DE TxD RxD REMOTE RTD MODULE CONNECTOR A B Com Shield J6 J3 D4 D5 D6 J7 CPU J1 Display J2 U3 RECEIVE TRANSMIT DEVICE ENABLE U6 CPU RIBBON CABLE CONNECTOR J5 810007 02-00 U1 U5 U7 DISPLAY RIBBON CABLE CONNECTOR U4 D3 D2 UJ1 UJ2 LED1 LED2 VALID SLAVE RESPONSE STATUS 124 7. 1 DRAWINGS RediStart Micro II Display Cut-out 2 27/32" MICRO DISPLAY CUT-OUT TEMPLATE (May not print to scale) 2 15/16" CUT-OUT SIZE: 5-3/8" x 2-5/8" HOLE PATTERN: 5-11/16" x 2-15/16" HOLE SIZE: 3/16" 5 11/16" 125 7. 1 DRAWINGS 126 8. PARAMETER LIST 8. 1 Parameter List RediStart Micro II Parameter List General The following pages list the menu parameters for the RediStart Micro II. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW RS7




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BENSHAW RS7 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.