User manual BENSHAW RS7
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BENSHAW RS7. We hope that this BENSHAW RS7 user guide will be useful to you.
Manual abstract: user guide BENSHAW RS7
Detailed instructions for use are in the User's Guide.
[. . . ] 57 57 57 57 58 58 59 59 60 60 60 61 61 61 61 62 62 63 63 63 63 64 65 65 65 66 66
5. 7 PROGRAMMING: Starter Setup - Jog Cntrl Setup . 71
iii
TABLE OF CONTENTS
5. 15 PROGRAMMING: Motor Protection - Line Current . % No C@Run (percent no current at run) No C@R Dly (no current at run delay) . 85 86 86 86
iv
TABLE OF CONTENTS
5. 28 PROGRAMMING: Meters & Relays - Standard Relays . [. . . ] When a motor is operating in the jog at set speed mode, its cooling capability is greatly reduced. Therefore, the running time of the motor is dependant on the motor current. If the jog at set speed will be used on a regular basis, the motor temperature should be monitored using a thermostat. The thermostat can be connected between the power and input terminal 1 of the JC13 terminal block on the RediStart Micro II computer card so that the starter will trip when a fault occurs. Alternatively, temperature monitoring devices, such as thermistors or RTDs can be used. This will prevent the motor from being overheated and inadvertently damaged. Due to the way the jog at set speed operates, the starter may require the installation of a 5% line reactor to eliminate harmonic problems being introduced into the power system. This is dependent on the size of the motor in relation to the capacity of the power system. Values Default The jog current is adjustable from 25% to 250% in 1% increments. Time (maximum time)
Description The maximum time parameter sets the time limit for continuous operation in the jog at set speed mode. This parameter should be set to a value that doesn't allow the motor to be operated in the jog at set speed mode for such a length of time that damage to the motor can occur. The default value for the Stab Cnst parameter is 100%.
Ramp#1 Tim
Description The Ramp#1 Tim parameter sets the length of time that the D. C. The Ramp#1 Tim is adjustable from 0 to 120 seconds in 1 second intervals. The default value for the Ramp#1 Tim is 15 seconds.
Values Default
Ramp#2 Tim
Description The Ramp#2 Tim parameter sets the length of time that the D. C. The Ramp#2 Tim is adjustable from 0 to 120 seconds in 1 second intervals. The default value for the Ramp#2 Tim is 15 seconds.
Values Default
61
5. 8 PROGRAMMING: Starter Setup - Tachometer Setup
TLoss Dela (Tachometer Signal Loss Delay)
Description The TLoss Delay time is the allowable time the starter will operate when a tachometer signal is lost. If the signal is lost, the starter will perform the action set by the TLoss Mode parameter. NOTE: Nuisance tachometer loss faults at start can be prevented by setting the initial current parameter to a value that allows the motor to begin rotating soon after a start is commanded. Values Default The TLoss Delay time parameter is adjustable from 0. 1 seconds to 90. 0 seconds in 0. 1 second intervals. The default value for the TLoss Delay time is 1. 5 seconds.
TLoss Mode (Tachometer Signal Loss Mode)
Description The TLoss Mode determines the starter's action if it has been detected the tachometer signal is lost. NOTE: If Current ramp or TruTorque ramp is selected, all values within these ramp profiles must be set for proper operation. NOTE: If Current ramp or TruTorque ramp is selected, and the tachometer signal is lost, the starter will shut down and automatically restart with the new starting mode. [. . . ] ONLY)
TBP2 START/STOP
1 2 3 4 5 1 2 3 4 5 6 7 8 9
K1 - RUN RELAY K1 K2 - LOCAL START RELAY K3 - LOCAL STOP RELAY
1 2
TBP8 SCR GATE 4 TBP9 SCR GATE 2
K4 - GENERAL FAULT RELAY (SHOWN IN FAULTED STATE)
1 2
TBP3 RELAY OUTPUTS
K5 - PROGRAMMABLE RELAY #1
K4 - PROGRAMMABLE RELAY #2
LEDP2 SCR STATUS (LOW VOLT. ONLY)
1 2
TBP10 SCR GATE 5
1 JP1 COMPUTER CARD RIBBON CABLE 2
1
TBP11 SCR GATE 3
LEDP3 SCR STATUS (LOW VOLT. ONLY) 1 2 3 4 5 6 7 8
1 2 SW1 SW2 (RIGHT - ON)
TBP12 SCR GATE 6
TBP4 CURRENT TRANSFORMERS
1 2 3
TBP13 TACH. INPUT
120
7. 1 DRAWINGS
RediStart Micro II Four (4) Relay Card Layout
TB2 RELAY OUTPUTS
1 24
TB1 CARD POWER
1 2
J1 RIBBON CABLE CONNECTOR
RediStart Micro II Seven (7) Relay Card Layout
K1 Relay
1 2 3
K2 Relay
4 5 6
K3 Relay
7 8 9
K4 Relay
10 11 12
K5 Relay
13 14 15
K6 Relay
16 17 18
K7 Relay
19 20 21
K1
K2
K3
K4
K5
K6
K7
HOT 1 2 3 4 NEUTRAL
TB3 120Vac Connector
FU1 J1
J1 Ribbon Cable Connector
121
7. 1 DRAWINGS
RediStart Micro II RS-232 Communications Card Layout
RECEIVE LED TRANSMIT LED
RIBBON CABLE CONNECTOR TO COMPUTER CARD
LED1 RXD
LED2 TXD
RS-232 IC
RS232 CARD
J2
TB1
9-PIN SUB-D MALE DCE PINOUT RS-232 CONNECTORS
TXD C COM RXD
RediStart Micro II RS-485 Communications Card Layout
RECEIVE LED TRANSMIT LED
DRIVER ENABLE
RIBBON CABLE CONNECTOR TO COMPUTER CARD
LED1 RXD
LED3 DE
LED2 TXD
RS485 CARD
RS-485 IC
TB1
J3
B(+) COM A(-) RS-485 CONNECTORS
9-PIN SUB-D FEMALE
122
7. 1 DRAWINGS
RediStart Micro II RS-232/485 Communications Card Layout
RIBBON CABLE CONNECTOR TO COMPUTER CARD
TRANSMIT LED RECEIVE LED
120 OHM TERM SHIELD TO COM
RS-485 CONFIGURATION SWITCHES
RS-485 TERMINAL BLOCK RS-232 CONNECTOR 9 PIN, SUB-D, FEMALE DCE PINOUT
RediStart Micro II Reversing/Braking Card Layout
TB3 SCR GATE 1A
TB4 SCR GATE 4A
TB5 SCR GATE 3A
TB6 SCR GATE 6A
TB7 SCR GATE 7/11
1 2
G4A 1 2
TB4 K4A
G6A 1 2
1 2
K1A
K3A
TB6 K6A
TB3 G1A
TB5 G3A
TB7 G7A
1 2 K7
COM
TB2 GATE POWER
21
+24VDC TB2
G4A G1A G6A G3A G7/11
TB1
TB1 GATE SIGNALS
123
7. 1 DRAWINGS
Modbus Master Card (for Remote RTD Module)
24VDC FROM POWER CARD
Gnd+24V
24VDC POWER SUPPLY
Com +24V J8 DE TxD RxD
REMOTE RTD MODULE CONNECTOR
A B Com Shield J6
J3
D4
D5
D6 J7
CPU J1
Display J2 U3
RECEIVE TRANSMIT DEVICE ENABLE
U6
CPU RIBBON CABLE CONNECTOR
J5 810007 02-00 U1 U5 U7
DISPLAY RIBBON CABLE CONNECTOR
U4 D3 D2 UJ1 UJ2
LED1
LED2
VALID SLAVE RESPONSE STATUS
124
7. 1 DRAWINGS
RediStart Micro II Display Cut-out
2 27/32"
MICRO DISPLAY CUT-OUT TEMPLATE (May not print to scale)
2 15/16"
CUT-OUT SIZE: 5-3/8" x 2-5/8" HOLE PATTERN: 5-11/16" x 2-15/16" HOLE SIZE: 3/16"
5 11/16"
125
7. 1 DRAWINGS
126
8.
PARAMETER LIST
8. 1 Parameter List
RediStart Micro II Parameter List
General The following pages list the menu parameters for the RediStart Micro II. [. . . ]