User manual BENSHAW MVRSM12

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BENSHAW MVRSM12. We hope that this BENSHAW MVRSM12 user guide will be useful to you.


BENSHAW MVRSM12 : Download the complete user guide (950 Ko)

Manual abstract: user guide BENSHAW MVRSM12

Detailed instructions for use are in the User's Guide.

[. . . ] BENSHAW REDISTART MICRO II INSTRUCTION MANUAL MVRSM12/18 SERIES Solid State Motor Control Technology Publication #: 890015-01-08 The Leader In TABLE OF CONTENTS Table of Contents 1. 42 43 44 44 45 45 45 45 46 46 46 47 47 5. 2 PROGRAMMING: Quick Start . 50 50 50 51 51 ii TABLE OF CONTENTS 5. 6 PROGRAMMING: Starter Setup - Forward2 Profile . 52 52 52 52 53 53 54 54 54 54 55 55 56 56 56 57 57 5. 7 PROGRAMMING: Starter Setup - Tachometer Setup . [. . . ] This means that decel level #1 is not set as a percentage of actual line voltage. If the motor initially surges when a stop is commanded, decrease this parameter value. If there is a sudden drop in motor speed when a stop is commanded, increase this parameter value. Values The decel level #1 is adjustable from 10% to 100% in 1% increments. The decel level #1 setting must be greater than the decel level #2 setting. The default value for the decel level #1 parameter is 40%. Default V Level #2 Description The V Level #2 parameter sets the ending voltage for the voltage ramp profile. This means that decel level #2 is not set as a percentage of actual line voltage. If the motor stops rotating before the deceleration time has expired, increase this parameter value. If the motor is still rotating when the deceleration time has expired, decrease this parameter value. Values The decel level #2 parameter is adjustable from 1% to 99% in 1% increments. The default value for the decel level #2 parameter is 20%. Default V DCL Time (decel time) Description The V DCL Time parameter sets the amount of time taken to go from the decel level #1 setting to the decel level #2 setting. If the motor stops rotating before the decel time has expired, decrease the decel time. If the motor is still rotating when the decel time expires, increase the decel time. Values Default The decel time parameter is adjustable from 0 to 60 seconds in 1 second intervals. The default value for the decel time parameter is 0 seconds. 56 5. 8 PROGRAMMING: Starter Setup - Decel Setup TT DCL Tim (TruTorque deceleration time) Description The TruTorque deceleration time sets how quickly the motor decelerates. To make the motor decelerate at a slower rate increase this time or to make the motor stop quicker decrease this time. The TruTorque deceleration time parameter is adjustable from 0 to 100 seconds in 1 second intervals The default TruTorque deceleration time is 0 seconds. Values Default TT DCL Tor (ending deceleration torque) Description The value sets the final torque level for the Trutorque deceleration ramp. If the motor is coming to a stop too quickly or if the starter continues to apply current to the motor after the motor has stopped this parameter can be increased in 5% increments. If the motor is still rotating when the desired deceleration time has expired, decrease this parameter by 5% and retest. Values Default The TruTorque deceleration ending torque value can be set from 1% to 100% torque in 1% steps. The default TruTorque deceleration ending torque setting is 10% 57 5. 9 PROGRAMMING: Starter Setup - PORT CTL Setup Fault Dly (Fault Delay) Description The Fault Dly parameter determines how long a power disturbance can exist before the micro system will fualt out on a power loss; and no longer restart. If the Fault Dly parameter is set to OFF, the PORT detection wil be disabled and the standard motor protection features will be enabled. [. . . ] INPUT 112 7. 1 DRAWINGS RediStart Micro II Four (4) Relay Card Layout TB2 RELAY OUTPUTS 1 24 TB1 CARD POWER 1 2 J1 RIBBON CABLE CONNECTOR RediStart Micro II Seven (7) Relay Card Layout K1 Relay 1 2 3 K2 Relay 4 5 6 K3 Relay 7 8 9 K4 Relay 10 11 12 K5 Relay 13 14 15 K6 Relay 16 17 18 K7 Relay 19 20 21 K1 K2 K3 K4 K5 K6 K7 HOT 1 2 3 4 NEUTRAL FU1 J1 TB3 120Vac Connector J1 Ribbon Cable Connector 113 7. 1 DRAWINGS RediStart Micro II RS-232 Communications Card Layout RECEIVE LED TRANSMIT LED RIBBON CABLE CONNECTOR TO COMPUTER CARD LED1 RXD LED2 TXD RS-232 IC RS232 CARD J2 TB1 9-PIN SUB-D MALE DCE PINOUT RS-232 CONNECTORS TXD C COM RXD RediStart Micro II RS-485 Communications Card Layout RECEIVE LED TRANSMIT LED DRIVER ENABLE RIBBON CABLE CONNECTOR TO COMPUTER CARD LED1 RXD LED3 DE LED2 TXD RS485 CARD RS-485 IC TB1 J3 B(+) COM A(-) RS-485 CONNECTORS 9-PIN SUB-D FEMALE 114 7. 1 DRAWINGS RediStart Micro II RS-232/485 Communications Card Layout RIBBON CABLE CONNECTOR TO COMPUTER CARD TRANSMIT LED RECEIVE LED 120 OHM TERM SHIELD TO COM RS-485 CONFIGURATION SWITCHES RS-485 TERMINAL BLOCK RS-232 CONNECTOR 9 PIN, SUB-D, FEMALE DCE PINOUT Modbus Master Card (for Remote RTD Module) 24VDC FROM POWER CARD J3 Gnd+24V 24VDC POWER SUPPLY Com +24V J8 DE TxD RxD REMOTE RTD MODULE CONNECTOR A B Com Shield J6 D4 D5 D6 J7 CPU J1 Display J2 U3 RECEIVE TRANSMIT DEVICE ENABLE U6 CPU RIBBON CABLE CONNECTOR J5 U5 U7 DISPLAY RIBBON CABLE CONNECTOR 810007 02-00 U1 U4 D3 LED1 D2 LED2 UJ1 UJ2 VALID SLAVE RESPONSE STATUS 115 7. 1 DRAWINGS RediStart Micro II Display Cut-out 2 27/32" MICRO DISPLAY CUT-OUT TEMPLATE (May not print to scale) 2 15/16" CUT-OUT SIZE: 5-3/8" x 2-5/8" HOLE PATTERN: 5-11/16" x 2-15/16" HOLE SIZE: 3/16" 5 11/16" 116 8. PARAMETER LIST 8. 1 Parameter List RediStart Micro II Parameter List General The following pages list the menu parameters for the RediStart Micro II. The list gives the page number where information on the parameter can be found. The list can also be used to record the values that are programmed into the RediStart Micro II for the installation. Each line lists the parameter, page reference, blank, and default setting. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW MVRSM12




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BENSHAW MVRSM12 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.