User manual BELKIN F6C650-SER-SB

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BELKIN F6C650-SER-SB. We hope that this BELKIN F6C650-SER-SB user guide will be useful to you.


BELKIN F6C650-SER-SB : Download the complete user guide (317 Ko)

Manual abstract: user guide BELKIN F6C650-SER-SB

Detailed instructions for use are in the User's Guide.

[. . . ] (The function is void when under condition of "LOW BATTERY". ) REAR PANEL (continued) Surge Surge Protection protection Outle t Outlet Backup Back up Protection Outlet Protection Outlet Communication Communication Port Port FOR MODELS F6C350-SER-SB F6C500-SER-SB F6C650-SER-SB AC AC Inlete t Inl Circuit Circuit Breaker Breaker RJ11/RJ45 Site Site RJ11/RJ45 Surge Protector WiringFault Surge Protector Wiring Fault USER MANUAL INTRODUCTION Have you ever noticed your lights dim or flicker when you turn on your dishwasher or air conditioner?This common occurrence is attributed to an under-voltage of power, also know as a brownout. It is the most common power problem, accounting for 80% of all power disturbances. Effects: A brownout can deprive a computer of the power it needs to function, causing unwanted damage to your computer­such as frozen keyboards and hard drive crashes. [. . . ] Disconnect nonessential equipment from the UPS to eliminate the overload. Fault (10 Seconds Continuously) When the output is shorted, the UPS emits a 10-second alarm. Disconnect the equipment from the UPS prior to checking the equipment. FRONT PANEL Press the button longer than three seconds to turn the UPS on or off. Press the button less than three seconds to activate the UPS self-testing or to silence the backup alarm. Low Battery/Replace Battery Fault/Overload COMMUNICATION INTERFACE Belkin Sentry Bulldog Shutdown Management Software and RS232 cable can be used with this UPS. If used, connect the interface cable to the computer interface port on the rear panel of the UPS, and then connect to the serial port on your PC. The communication port provides the following features: 1) Monitors charger status 2) Monitors UPS status 3) Monitors battery status and condition 4) Monitors the utility status 5) Provides power-switch function for power saving REAR PANEL Interface Port Provides RS232 to relay the signal to support DOS, Windows, and other operating systems. Phone/Fax/Modem/DSL or Network Protection Telephone/fax/modem lines are surge protected and provide complete safety for Internet connection. modem and fax). On Line/On Battery On/Off/Test P73506-UPS manual S-series. qxd 2/28/01 1:34 PM Page 2 SOFTWARE OPTIONS Belkin Sentry Bulldog Shutdown Management Software Belkin Sentry Bulldog Shutdown Management Software receives communication through the RS232 interface port to perform monitoring functions, and also provide an orderly shutdown of the computer in the event of a power failure. Moreover, Belkin Sentry Bulldog Shutdown Management Software displays all of the diagnostic symptoms on screen, such as voltage level, frequency, battery level, etc. The software is available for Windows® 95, Windows® 98, Windows NT® V4 or higher, Windows® 2000, Windows® Me, Unix®, and Novell® 3. X and above. Interface Kits Each interface kit includes a special interface cable which is required to convert status signals from the UPS into signals that the individual operation system can recognize. The interface cable must be connected to the (RS232) serial port on the UPS. The other side of the interface cable can be connected to the DB9 serial port on your PC. For other installation instructions and features, please refer to the READ. ME file. Caution: Use only factory supplied or UPS monitoring cable! STORAGE Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Disconnect any cables connected to the computer interface port to avoid unnecessary drainage of the battery. Extended Storage During extended storage in environments where the ambient temperature is +5° F to +86° F, charge the UPS battery every six months. During extended storage in environments where the ambient temperature is +86° F to +113° F, charge the UPS battery every three months. Note: BELKIN COMPONENTS USER LICENSE AGREEMENT LICENSE: You have the non-exclusive right to use the software. You are not permitted to copy, modify or transfer the software or documentation. You may not decompile, disassemble or otherwise reverse engineer, break down, analyze or modify the software. USE AND RESTRICTIONS: You are permitted to make backup copies of all the software disks for archival purposes only. [. . . ] · When the UPS has been unused for some time, the battery inside will discharge slightly. It is recommended to plug the UPS into a wall outlet to let the battery begin charging automatically. · When cleaning the plastic case or front panel, use only a soft, dry cloth. If the case or front panel is very dirty, use a neutral, non-abrasive detergent. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BELKIN F6C650-SER-SB




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BELKIN F6C650-SER-SB will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.