User manual BELKIN F6C1000-TW-RK

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BELKIN F6C1000-TW-RK. We hope that this BELKIN F6C1000-TW-RK user guide will be useful to you.


BELKIN F6C1000-TW-RK : Download the complete user guide (388 Ko)

Manual abstract: user guide BELKIN F6C1000-TW-RK

Detailed instructions for use are in the User's Guide.

[. . . ] Turning on the UPS Turn on your UPS by pressing and holding the On/Off/Test button for approximately 2 seconds until the "ON LINE" Green comes on. Turning off the UPS Turn off the UPS by pressing and holding the On/Off/Test button for more than 2 seconds until the "ON LINE" or "ON BATTERY" LED goes off. To Conduct a Self Test Use the self-test to verify both the operation of the UPS and the condition of the battery. In normal utility power, push the On/Off/Test button less than 1. 5 seconds and the UPS performs a self-test function. [. . . ] The phone/ fax/modem protection feature could be rendered inoperable if improperly installed. Make sure that the telephone line from the wall is plugged into the connector marked "IN", and the device to be protected is plugged into the connector marked " OUT". BATTERY REPLACEMENT PROCEDURE Replacement requires removing the battery cover plate on the front of the UPS. Press fastener to remove the battery cover plate on the front of the UPS (Fig. Remove the battery then insert a new battery pack, and push the connectors onto the battery terminals (black to black & red to red) (Fig. NOTE: There may be a small spark at the battery terminals when reconnecting the connectors. 1). Connect the Network Protection Lines Connect the network line from the wall to the connector marked "IN", then connect the device (Ethernet card) to be protected to the connector marked "OUT". * All equipment must be turned off prior to hardware installation. SYSTEM REQUIREMENTS The UPS can be used without the software and can be used with any computer using a monitor or a flat panel screen. Also, you do not have to have the software installed to utilize the battery backup outlets. To fully utilize the UPS and its software, your computer must be able to operate the following operating systems: 95/ 98/ ME/ NT4/ 2000/ 2003/ XP & Linux & Higher and have a Serial or USB port. To fully utilize the Bulldog Plus Shutdown Software; you will need to connect the UPS to your computer. Use the ON/OFF/TEST UPS power switch function to schedule UPS for power saving SERIAL OR USB COMMUNICATION PORT (INSTALLATION OPTIONAL) Fig. 4 for Model: F6C1000-TW-RK F6C1250-TW-RK You should have received the following: 1 ­ UPS unit 1 ­ Bulldog Plus Shutdown Software 1 ­ USB Cable 1 ­ Serial Cable 1 ­ Phone Line Cable You may connect the UPS to your computer by choosing either the Serial or USB ports. Software Installation (Installation Optional) To fully utilize the UPS and its software, your computer must be able to operate the following operating systems: Windows98/ ME/ NT4/ 2000 / 2003/ XP and have a USB port. TECHNICAL SPECIFICATIONS MODEL Capacity INPUT Voltage Range Frequency Voltage OUTPUT Frequency (On battery) Back up time 50%~100% load Typical Recharge Time F6C1000TW-RK F6C1250TW-RK F6C1500TW-RK A) 1000VA/ 615W 1250VA/ 680W 88-140Vac 60HZ ( ±3HZ ) 1500VA/ 830W Your UPS features the Bulldog Plus Shutdown Software. This allows you to protect and save your data should a power outage occur, as well as safely shutdown your computer in your absence. Please be sure to close out of all applications prior to installing the software. To install the software, please place the CD into the CD drive of your computer. If this does not occur, go to the Run feature on your Start icon (lower left corner) on your screen. Please enter the CD drive, it may be D: Upon entering the drive run setup. exe. Should you continue to have a problem, please refer to your computer's owner's manual for the correct drive. The "Welcome to the Belkin Bulldog Plus Product Installation Browser" will appear. Networking management is for administrators who need to manage several UPSes in a workstation environment. You should not install the networking files unless you are technically qualified to use these features. [. . . ] ACKNOWLEDGMENT: By opening the package on which this Agreement is printed, or through which it is visible, you acknowledge that you have read this Agreement, understand it, and agree that this agreement is the complete and exclusive statement of agreement between yourself and Belkin and supersedes any prior agreements, oral or written, and any other communications relating to the subject matter of this Agreement. SEVERABILITY: Any term or provision of this Agreement or any application thereof, which may be prohibited or unenforceable by law in a particular jurisdiction, shall be interpreted and enforced to the maximum extent allowed in such jurisdiction (which the parties acknowledge could mean severing the provision from this Agreement or, if allowed, enforcing it in a narrower form), without affecting the remainder of this Agreement, or any other application of such term or provision in such jurisdiction, or application of such term or provision in any jurisdiction. The unit is intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Recycling Information Your UPS contains a Non-spillable Sealed Lead Battery. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BELKIN F6C1000-TW-RK




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BELKIN F6C1000-TW-RK will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.