User manual BELIMED WD425E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BELIMED WD425E. We hope that this BELIMED WD425E user guide will be useful to you.


BELIMED WD425E : Download the complete user guide (468 Ko)

Manual abstract: user guide BELIMED WD425E

Detailed instructions for use are in the User's Guide.

[. . . ] 78563_E Operating Manual WD 425E TABLE OF CONTENT !IMPORTANT NOTICE!. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 !CAUTION!. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 !WARNING!. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1. 1. 1 1. 2 General Directives ref. [. . . ] 1. 1, LS Operating Manual WD 425E Input by barcode reader: When entering N° 0, text , , No ID" is passed on. They may be downloaded from the internet at no cost, see under http://www. barcodemagic. com/barcodemagic. html. Barcode Type Code 39 EAN13 Heike Müller Heike Mueller The interrogation may be activated / deactivated in the configuration module. No ID / Exit 3. 4 Rack Detection Importing rack or Wash goods carrier-N° by keyboard or importing rack name by barcode reader for batch documentation. With active Rack detection, the following is displayed: Rack name or N°? -The machine either reads a 2-digit number of the 6 program keys from 11 - 66 or a text by barcode scanner. 36) or name is passed on to the printer or to the digital documentation system 8565 and assigned to the respective batch. A program can be launched only if the input is complete, otherwise the SW remains in interrogation mode. Input by keyboard: Input N° 66 is passed on as text , , No ID ". Input by barcode reader: Importing N° 0 will be passed on as , , N° ID ". Interrogation may activated / deactivated in the configuration module 5. 3. 5 Identification Batch Content Importing N° of wash goods (e. g. Sieve trays) by keyboard or importing wash goods name or N° by barcode reader for batch documentation. With active Batch ID and open door, instead of , , UC door open ", the following is displayed: Read Batch Content N° = -- ?The machine either reads a 2-digit number of the 6 program keys from 11 - 66 or a text or a N° by barcode scanner. 36) or name is passed on to the printer or to the digital documentation system 8565 and assigned to the respective batch. Rev. 1. 1, LS Page 17 of 34 78563_E rev 1. 1. doc Operating Manual WD 425E As a maximum, 18 objects may be imported. A program can be launched only once the input is complete, otherwise the SW remains in interrogation mode. Input by keyboard: Entering N° 66, text , , No ID" is passed on and the procedure is terminated. The reading process may be terminated at any time by the , , IO" key. On the display, indication of number of batch contents terminate the procedure. Once the maximum of 18 batch contents is reached, following inputting the 18th item, instead of , , Read batch content ", , , Max batch content " appears and the importing will be terminated without entering N° 0, i. e. the program may be launched. N° Batch Content 12 The rack may be pushed in machine. Preferably, the barcode N° 0 is attached to the unit. No ID / Exit Interrogation may be activated / deactivated in configuration module 5. Rev. 1. 1, LS Page 18 of 34 78563_E rev 1. 1. doc Operating Manual WD 425E 3. 6 Endoscope Identification With active endoscope detection, with door open, display shows "Interrogation Batch Content" instead of , , Door open ". [. . . ] Error code 172 Cause: Left endoscope or endoscope adapter has a leak and must be repaired. Endoscope protection: during cleaning phase, upper limit pressure (350 mbar) of inside Endo protection pressure has been exceeded in left side endoscope. During venting phase, in left side endoscope Error code 174 system, pressure drop of 1. 5 V was not attained within 10 minutes. Air exhaust is clogged, test valves or the pressure sensor PL is defective. 172 173 174 175 During test pressure build-up during filling phase, test pressure in right hand endoscope of Right endo leaks 280/ 230 mbar (2. 74/ 2. 34 V) has not been reached within 10 minutes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BELIMED WD425E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BELIMED WD425E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.